Vortice 11638

Vortice 11638 Centrifugal Extractor Fan Micro 80 for Ducts - User Manual

Model: 11638 | Brand: Vortice

1. Product Overview

The Vortice Micro 80 Centrifugal Extractor Fan, Model 11638, is a high-performance ventilation unit designed for efficient air extraction in ducted systems. Its compact design and robust construction make it suitable for various applications, particularly in bathrooms and utility rooms. This fan is engineered for reliability and quiet operation, ensuring effective air circulation.

Vortice Micro 80 Centrifugal Extractor Fan, angled view

Figure 1.1: Angled view of the Vortice Micro 80 Centrifugal Extractor Fan, showcasing its white ABS plastic casing and front grille design.

Vortice Micro 80 Centrifugal Extractor Fan, front view

Figure 1.2: Front view of the Vortice Micro 80 fan, highlighting the nine circular vents and the 'Vortice' logo.

2. Safety Information

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Setup and Installation

The Vortice Micro 80 fan is designed for wall mounting and connection to ductwork. Ensure the mounting surface is stable and capable of supporting the unit's weight.

3.1 Package Contents

3.2 Mounting the Unit

  1. Choose a suitable wall location, ensuring adequate space for duct connection and maintenance.
  2. Mark the drilling points on the wall using the fan's mounting holes as a template.
  3. Drill holes and insert appropriate wall plugs.
  4. Secure the fan to the wall using the provided screws.

3.3 Electrical Connection

The fan operates on 220-240V AC. It features a 2-speed induction motor. Wiring should be done by a qualified professional.

  1. Ensure the main power supply is OFF before making any connections.
  2. Open the wiring compartment on the fan.
  3. Connect the live (Phase) and neutral wires to the designated terminals. The fan supports two speeds, which can be controlled via an external regulator (not included). Refer to the wiring diagram for specific connections for each speed.
  4. Connect the ground wire to the grounding terminal.
  5. Close the wiring compartment securely.

3.4 Duct Connection

The fan is designed for 80 mm diameter ducts.

Internal view of Vortice Micro 80 fan showing impeller and duct connection point

Figure 3.1: Internal view of the fan, illustrating the centrifugal impeller and the circular opening for duct connection. Note the backdraft damper.

  1. Connect the appropriate ducting to the fan's outlet. Ensure a tight and secure fit to prevent air leaks.
  2. The fan includes a non-return valve (backdraft damper) to prevent air from flowing back into the room when the fan is off. Ensure it operates freely.
Technical drawing with dimensions of Vortice Micro 80 fan

Figure 3.2: Technical drawing providing detailed dimensions (in mm) of the Vortice Micro 80 fan from various perspectives, useful for installation planning.

4. Operating Instructions

The Vortice Micro 80 fan features a 2-speed motor for flexible ventilation control.

4.1 Powering On/Off

Once installed and wired, the fan can be switched on or off via a wall switch connected to its power supply.

4.2 Speed Control

The fan's two speeds (low and high) can be selected using a compatible external speed regulator (e.g., a Vortice regulator) or a dual-switch setup, if wired accordingly. The low speed provides a flow rate of 60 m³/h, while the high speed provides 85 m³/h.

Performance curve graph for Vortice Micro 80 fan

Figure 4.1: Performance curve graph for the Vortice Micro 80 fan, illustrating the relationship between pressure (P), flow rate (Q), and power consumption (W) at different operating points.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your Vortice Micro 80 fan. Always disconnect power before performing any maintenance.

6. Troubleshooting

If you experience issues with your Vortice Micro 80 fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn onNo power supply
Loose wiring
Thermal fuse tripped
Check circuit breaker/fuse
Verify all electrical connections (by a qualified electrician)
Allow fan to cool down; if problem persists, consult service
Low airflowBlocked ducting
Dirty impeller
Backdraft damper stuck
Check and clear duct obstructions
Clean impeller blades
Ensure damper moves freely
Excessive noiseLoose mounting
Debris in impeller
Motor issue
Tighten mounting screws
Clean impeller
If noise persists, contact service

If the problem persists after attempting these solutions, please contact a qualified service technician.

7. Specifications

Detailed technical specifications for the Vortice 11638 Centrifugal Extractor Fan:

ParameterValue
Model Number11638
BrandVortice
TypeCentrifugal Extractor Fan
ColorWhite
MaterialABS Plastic
Dimensions (L x W x H)11.7 x 23.9 x 23.9 cm (4.6 x 9.4 x 9.4 inches)
Weight1.79 kg (3.95 lbs)
Power SourceElectric Cable
Voltage220-240 V
Max Absorbed Power (High Speed)27 W
Max Absorbed Power (Low Speed)19 W
Max Absorbed Current (High Speed)0.13 A
Max Flow Rate (High Speed)85 m³/h (24 L/s)
Min Flow Rate (Low Speed)60 m³/h (17 L/s)
Max Pressure (High Speed)265 Pa (27 mmH₂O)
Max Pressure (Low Speed)216 Pa (22 mmH₂O)
Sound Pressure Level @ 3m (High Speed)37 dB(A)
Sound Pressure Level @ 3m (Low Speed)28.7 dB(A)
Max RPM1580
Min RPM1150
Max Ambient Operating Temperature50 °C
Country of OriginItaly

8. Warranty and Support

Specific warranty information for the Vortice 11638 fan is not available in this manual. Please refer to the product packaging or contact your retailer or the manufacturer directly for warranty details.

For technical support or service inquiries, please contact Vortice customer service or an authorized service center. Ensure you have your product model number (11638) and purchase date available when contacting support.

Related Documents - 11638

Preview Manuale di Istruzioni Vortice Punto: Modelli M 90, M 100, M 120, M 150
Manuale completo per l'installazione, l'uso e la manutenzione degli aspiratori Vortice Punto, con dettagli sui modelli M 90, M 100, M 120, M 150 e M 100 12V. Include avvertenze di sicurezza e specifiche tecniche.
Preview Vortice Ventilation Systems: Installation and Maintenance Guide
Comprehensive guide for Vortice ventilation systems, covering installation, electrical connection, maintenance, and safety precautions for various axial and centrifugal fan models.
Preview Vort Max ES Centrifugal Aspirator: Installation and User Manual
Comprehensive instruction manual for the Vortice Vort Max ES wall-mounted centrifugal aspirator, covering product description, compliance, safety warnings, installation, maintenance, wiring diagrams, and disposal.
Preview Vort Quadro: Manuale d'Uso e Installazione
Manuale completo per i ventilatori centrifughi Vort Quadro di Vortice (Micro 80, 100, Medio, Super). Include istruzioni di installazione, funzionamento, manutenzione e sicurezza.
Preview Vortice VORT QUADRO MEDIO - Manuale di Istruzioni
Manuale di istruzioni completo per l'aspiratore centrifugo Vortice VORT QUADRO MEDIO, che include dettagli su installazione, funzionamento, modelli, manutenzione e avvertenze di sicurezza.
Preview Manuale di istruzioni Vortice VORT QUADRO - Serie MICRO
Manuale completo per l'installazione, l'uso e la manutenzione dei ventilatori estrattori Vortice VORT QUADRO, modelli MICRO 80, MICRO 100, MICRO 80 T, MICRO 100 T e MICRO 100 T HCS. Include guide dettagliate su sicurezza, collegamenti elettrici e funzionalità.