Product Overview
The Dixie EMS Blood Pressure and Sprague Stethoscope Kit is a comprehensive medical device designed for accurate blood pressure measurement and auscultation. This deluxe kit is suitable for medical professionals, students, and home users.
Key Components:
- Aneroid Sphygmomanometer (Blood Pressure Cuff)
- Sprague Rappaport Stethoscope
- Accessory Kit (replacement parts)
- Deluxe Carrying Case

Figure 1: Complete Dixie EMS Blood Pressure and Sprague Stethoscope Kit in Burgundy.
Product Features:
- Latex-Free Blood Pressure Cuff: Designed to fit adult arms between 10" and 16" in circumference. Features a PVC inflation bag with screw-type and push-type air release valves for precise and rapid deflation.
- High Contrast & Easy-to-Read Dial: The aluminum alloy manometer features a clear, high-contrast dial for accurate blood pressure readings. Includes a sturdy clip for attachment to clothing.
- Dual-Head Sprague Stethoscope: Suitable for patients of all ages. Features flexible and adjustable eartubes for comfortable use and comes with extra earpieces for customization.
- Convenient Carrying Case: A zippered, water-resistant case to keep all components secure and facilitate easy transport.

Figure 2: The deluxe carrying case, designed for secure and portable storage of the kit.

Figure 3: Close-up of the Sprague Stethoscope, highlighting its dual-head design.

Figure 4: The blood pressure cuff with its integrated manometer for accurate readings.
Setup and Assembly
The Dixie EMS Blood Pressure and Sprague Stethoscope Kit comes pre-assembled for most components. Ensure all parts are present and in good condition before first use.
Initial Inspection:
- Unpack all items from the carrying case.
- Verify the presence of the blood pressure cuff, manometer, stethoscope, inflation bulb, and accessory kit.
- Check all tubing and connections for any signs of damage or leaks.
Video Guide:
Video 1: Overview and demonstration of the Dixie EMS Blood Pressure and Sprague Stethoscope Kit, including components and basic setup. (Duration: 0:38)
Operating Instructions
Follow these steps for accurate blood pressure measurement using your Dixie EMS kit.
Measuring Blood Pressure with Stethoscope:
- Twist the air release valve all the way to the right to close it off.
- Wrap the cuff around the arm just above the elbow. Keep it snug but not too tight.
- Place the stethoscope head on the brachial artery and find the pulse.
- Pump air into the cuff until you no longer hear the pulse.
- Slowly release the valve and listen to the beats.
- Record the first and the last heart beat you hear (systolic and diastolic pressure).

Figure 5: Step-by-step visual guide for measuring blood pressure using the cuff and stethoscope.
Measuring Blood Pressure without Stethoscope (Palpation Method):
- Twist the air release valve all the way to the right to close it off.
- Wrap the cuff around the arm just above the elbow. Keep it snug but not too tight.
- Place your fingertips on the radial artery near the wrist and find the pulse.
- Pump air into the cuff until you no longer feel the pulse.
- Slowly release the valve and feel for the first pulse.
- Record the first heart beat you feel (systolic pulse as taken by palpation).

Figure 6: Step-by-step visual guide for measuring blood pressure using the cuff without a stethoscope (palpation method).
Maintenance
Proper maintenance ensures the longevity and accuracy of your Dixie EMS kit.
Cleaning:
- Wipe down the cuff and stethoscope tubing with a soft cloth dampened with mild soap and water.
- Do not immerse the manometer or inflation bulb in water.
- Allow all components to air dry completely before storing.
Calibration:
Regular calibration is essential for maintaining accuracy.
- Use the release valve to deflate the cuff and see if the manometer returns to 0.
- If the manometer doesn't return to 0, use the included calibration key to adjust.

Figure 7: Visual guide for checking and adjusting the manometer calibration.
Storage:
- Store the kit in its deluxe carrying case when not in use.
- Keep in a cool, dry place away from direct sunlight and extreme temperatures.
Troubleshooting
This section provides solutions to common issues you might encounter with your kit.
- Inaccurate Readings: Ensure the cuff is correctly positioned and snug. Check manometer calibration (refer to Maintenance section). Verify no air leaks in tubing or connections.
- Difficulty Hearing Pulse: Ensure the stethoscope head is firmly placed on the brachial artery. Check that the eartubes are correctly oriented and the diaphragm/bell is open.
- Cuff Not Inflating: Ensure the air release valve is fully closed. Check for any punctures or damage to the inflation bulb or cuff.
If issues persist, please contact customer support.
Specifications
| Feature | Detail |
|---|---|
| Brand | Dixie EMS |
| Model Number | B008BTYWCY |
| Product Dimensions | 8 x 2 x 4.5 inches; 1.26 Pounds |
| Material Feature | Latex Free |
| Cuff Size | Adult (10" to 16" arm circumference) |
| Display Type | Analog |
| Included Components | Cuff, Kit, Stethoscope, Case |
| Manufacturer | Everready First Aid |
| Date First Available | August 28, 2013 |

Figure 8: Product packaging with key dimensions.
Warranty and Support
Specific warranty details are not provided in the product information. For any inquiries regarding warranty, product support, or replacement parts, please contact Dixie EMS directly.
You can visit the official Dixie EMS store for more information and support: Dixie EMS Store