TICA LZ5000

TICA LZ5000 Cambria Lz Series Spinning Reel Instruction Manual

Model: LZ5000

Introduction

This manual provides detailed instructions for the proper setup, operation, and maintenance of your TICA LZ5000 Cambria Lz Series Spinning Reel. Please read this manual thoroughly before using your reel to ensure optimal performance and longevity. Retain this manual for future reference.

TICA LZ5000 Cambria Lz Series Spinning Reel

Figure 1: The TICA LZ5000 Cambria Lz Series Spinning Reel, showcasing its overall design and components.

Product Features

The TICA LZ5000 Cambria Lz Series Spinning Reel incorporates several design elements for enhanced fishing experience:

Setup

1. Attaching the Reel to a Fishing Rod

  1. Loosen the reel seat nut on your fishing rod.
  2. Slide the reel foot into the reel seat.
  3. Tighten the reel seat nut securely until the reel is firmly attached and does not wobble.

2. Spooling Fishing Line

The LZ5000 reel comes with a double anodized machined aluminum spool. An additional spool may be included or purchased separately for different line types or capacities.

Two TICA Cambria Spinning Reel Spools

Figure 2: Two spools for the TICA Cambria Lz Series Spinning Reel, illustrating their design and line capacity markings.

  1. Open the bail arm.
  2. Tie the fishing line to the spool using an arbor knot or a similar secure knot. Trim any excess tag end.
  3. Close the bail arm.
  4. Hold the line under slight tension and begin to reel slowly. Ensure the line is spooling evenly.
  5. Fill the spool to approximately 1/8 inch (3mm) from the rim to prevent line overflow and tangles.

3. Adjusting Handle Orientation

The handle can be switched from left to right side operation:

Close-up of TICA LZ5000 Spinning Reel Handle

Figure 3: A close-up view of the TICA LZ5000 spinning reel handle, showing its ergonomic design.

  1. Unscrew the handle knob on the side opposite to where the handle is currently inserted.
  2. Pull the handle out from the reel body.
  3. Insert the handle into the desired side.
  4. Screw the handle knob back into the opposite side to secure the handle.

Operating Instructions

1. Casting

  1. Hold the rod and reel comfortably.
  2. Open the bail arm.
  3. Grip the fishing line with your index finger.
  4. Swing the rod forward, releasing the line with your index finger at the appropriate moment to cast your lure or bait.
  5. As the lure approaches the water, close the bail arm manually or by turning the handle to prepare for retrieve.

2. Retrieving

Turn the handle clockwise (for right-hand retrieve) or counter-clockwise (for left-hand retrieve) to reel in the line. The intelligent oscillating system ensures even line lay.

3. Drag Adjustment

The drag system controls the amount of resistance the line experiences when a fish pulls on it. Adjusting the drag correctly prevents line breakage.

Close-up of TICA LZ5000 Spinning Reel Drag Knob

Figure 4: A close-up of the drag adjustment knob on the TICA LZ5000 spinning reel, located at the front of the spool.

4. Anti-Reverse Function

The instant anti-reverse system prevents the rotor from turning backward, providing solid hook sets. This feature is always engaged on the LZ5000 model.

Maintenance

Regular maintenance extends the life and performance of your TICA LZ5000 spinning reel.

1. Cleaning After Use

2. Lubrication

3. Storage

Troubleshooting

ProblemPossible CauseSolution
Line tangles or loops on spoolOver-spooling, line twist, or improper line lay.Reduce line amount, check for line twist, ensure even line lay during spooling.
Stiff or grinding retrieveLack of lubrication, dirt/debris in gears, damaged bearings.Clean and lubricate the reel. If problem persists, professional service may be required.
Drag slips or is inconsistentDrag washers are dry, worn, or contaminated.Clean and lightly grease drag washers. Replace if worn.
Bail arm does not close properlyDebris in bail mechanism, bent bail wire, or worn spring.Clean bail mechanism. Inspect for damage.

Specifications

Close-up of TICA LZ5000 Spinning Reel Spool with Line Capacity

Figure 5: A detailed view of the TICA LZ5000 spool, showing the line capacity markings.

FeatureDetail
Model NumberLZ5000
Gear Ratio4.3:1
Bearings4 Precision Stainless Steel Ball Bearings + 1 Anti-Reverse Roller Bearing
Hand OrientationAmbidextrous (Left/Right Interchangeable)
Spool MaterialDouble Anodized Machined Aluminum
Anti-Reverse SystemInstant Anti-Reverse
Item Weight15.5 Ounces (approx. 439.42 g)
Line Capacity (approximate)
  • 5 lb (0.22mm) / 230 yds (210m)
  • 6 lb (0.25mm) / 180 yds (160m)
  • 8 lb (0.28mm) / 150 yds (140m)
  • 10 lb (0.30mm) / 120 yds (110m)
  • 12 lb (0.32mm) / 100 yds (90m)
Package Dimensions15.5 x 15 x 10.5 cm

Related Documents - LZ5000

Preview TICA Air-Conditioner Remote Controller Operating Guide | User Manual
Comprehensive operating guide for the TICA air-conditioner remote controller. Learn how to use all functions, precautions, and maintenance tips for your TICA AC remote.
Preview TICA Ventilator (Heat Recovery Fresh Air Handling Unit) Installation & Operation Manual
This manual provides detailed instructions for the installation and operation of TICA's Ventilator (Heat Recovery Fresh Air Handling Unit), including product overview, features, specifications, electrical diagrams, and maintenance guidelines for models TRV015, TRV025, and TRV035 series.
Preview TICA MINI VRF (CHR/CSREA Series) Installation and Operation Manual
Comprehensive installation and operation manual for TICA MINI VRF air conditioning units, CHR/CSREA series. Covers safety precautions, ODU installation, refrigerant piping, electrical wiring, control panel settings, and troubleshooting.
Preview TICA Inverter Multi System Unit Installation and Operation Manual
Comprehensive guide for installing and operating TICA Inverter Multi System Units (TIMS-X/XA/XT/C series), covering safety, ODU installation, refrigerant piping, electrical wiring, control panel settings, and trial operation.
Preview TICA Inverter Multi System Unit Installation and Operation Manual
This manual provides comprehensive installation, operation, and safety guidelines for TICA Inverter Multi System Units (TMS-S/ST/SA/SRYA series), covering ODU installation, refrigerant piping, electrical setup, control panel functions, and trial operation.
Preview TICA TIMS Inverter VRF System Product Catalog and Specifications
Comprehensive catalog detailing TICA's TIMS Inverter VRF System, featuring advanced air conditioning technology, product specifications, features, and applications for commercial and residential use. Includes TIMS-X, TIMS-S models and various indoor units.