Kenstar Vibrant

Kenstar Vibrant 20L Air Cooler User Manual

Model: Vibrant

Introduction

Thank you for choosing the Kenstar Vibrant 20L Air Cooler. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new appliance. The Vibrant Cooler features a sleek design and is designed for effective cooling in compact and small spaces, preventing mosquitos and small insects from entering the cooling pads for cleaner air.

Important Safety Instructions

  • Read all instructions carefully before operating the cooler.
  • Ensure the power supply matches the voltage specified on the cooler (150-240 volts).
  • Do not immerse the cooler, cord, or plug in water or other liquids.
  • Always unplug the cooler from the power outlet before cleaning, servicing, or moving.
  • Keep the cooler away from children and pets.
  • Do not operate the cooler with a damaged cord or plug.
  • Place the cooler on a stable, level surface to prevent tipping.

Product Overview

The Kenstar Vibrant 20L Air Cooler is designed for efficient personal cooling. Key features include:

  • Product Dimensions: 345mm (W) x 340mm (D) x 885mm (H)
  • Air Throw Distance: 35 feet
  • Air Delivery: 1160 m³/hr
  • Air Deflection: 4-way
  • Speed Settings: 3 speeds
  • Cooling Area: 20 square meters
  • Louvre Movement: Motorized (Vertical)
  • Cooling Media: Honeycomb evaporative pads
  • Capacity: 20 liters
  • Special Feature: Mosquito/Insect Protection
Kenstar Vibrant 20L Air Cooler, white color, front view.

This image shows the Kenstar Vibrant 20L Air Cooler in white, highlighting its compact tower design and control panel.

Setup

Unpacking

  1. Carefully remove the cooler from its packaging.
  2. Remove all packing materials, including any protective films or tapes.
  3. Inspect the cooler for any signs of damage. If damaged, do not operate and contact customer service.

Placement

  • Place the cooler on a firm, level surface to ensure stability and proper water distribution.
  • Ensure there is adequate space around the cooler for proper air intake and exhaust. Avoid placing it directly against a wall.
  • For optimal cooling, position the cooler near an open window or door to draw in fresh air.

Water Filling

  1. Locate the water inlet on the cooler.
  2. Fill the water tank with clean, fresh water. The maximum capacity is 20 liters.
  3. Do not overfill the tank beyond the 'MAX' indicator to prevent spillage.
  4. For enhanced cooling, you may add ice cubes to the water tank if a dedicated ice chamber is present (refer to product design).

Operating Instructions

Power Connection

  1. Ensure the cooler is correctly positioned and the water tank is filled.
  2. Plug the power cord into a suitable 150-240 volt AC power outlet.

Control Panel

The Kenstar Vibrant cooler features a user-friendly button control panel.

  • Power Button: Press to turn the cooler ON or OFF.
  • Speed Button: Cycle through the 3 available fan speeds (Low, Medium, High) to adjust airflow.
  • Swing Button: Activate or deactivate the motorized vertical louvre movement for wider air distribution.

Maintenance

Regular maintenance ensures optimal performance and longevity of your Kenstar Vibrant Air Cooler.

Cleaning the Exterior

  • Always unplug the cooler before cleaning.
  • Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.

Cleaning the Water Tank

  • Drain any remaining water from the tank using the drain plug (if available) or by carefully tilting the unit.
  • Clean the inside of the water tank with a mild detergent and water. Rinse thoroughly to remove all soap residue.
  • Regularly clean the water tank to prevent algae growth and maintain air quality.

Cleaning Honeycomb Pads

  • The honeycomb pads should be cleaned periodically, especially if you notice reduced airflow or an odor.
  • Refer to the cooler's design for access to the pads. Gently remove them and rinse under running water to remove dust and mineral deposits.
  • Allow the pads to dry completely before reinserting them.

Mosquito/Insect Protection

The cooler is designed with features to prevent mosquitos and small insects from entering the cooling pads. Ensure all covers are properly secured after maintenance to maintain this protection.

Troubleshooting

Before contacting customer service, please refer to the following common issues and solutions:

ProblemPossible CauseSolution
Cooler does not turn onNo power supply; Power cord not plugged in; Fuse blownCheck power outlet; Ensure cord is securely plugged in; Check household fuse/circuit breaker.
No cooling effectLow water level; Water pump not working; Dirty honeycomb padsFill water tank; Check if pump is operating (listen for sound); Clean honeycomb pads.
Water leakageOverfilling the water tank; Drain plug not secured; Unit not levelDo not fill past 'MAX' line; Ensure drain plug is tightly closed; Place cooler on a level surface.
Unusual noiseObstruction in fan; Unit not level; Loose componentsUnplug and check for obstructions; Ensure unit is level; Contact service if noise persists.

Specifications

FeatureSpecification
BrandKenstar
Model NameVibrant
MaterialFibre
Mounting TypeFreestanding
ColourWhite
Controls TypeButton
Reservoir Capacity20 Liters
Item Weight12 Kilograms
Recommended UsesResidential cooling in small to medium rooms or apartments
Wattage130 Watts
Number Of Speeds3
Voltage150-240 Volts
Item Dimensions (D x W x H)34D x 34.5W x 88.5H Centimeters
Special FeaturesMotorized Louvre Movement, Mosquito/Insect Protection

Warranty and Support

Warranty Information

The Kenstar Vibrant 20L Air Cooler comes with a 1-year warranty on the product from the date of purchase. Please retain your purchase receipt as proof of warranty.

Customer Support

For any service, repair, or warranty claims, please contact Kenstar customer service. Refer to the contact information provided with your product packaging or visit the official Kenstar website for support details.

© 2023 Kenstar. All rights reserved.