1. Introduction
This manual provides instructions for the Remington SP-HC5000 Replacement Guide Combs. These combs are designed to be used with specific Remington Groom Innovation hair clippers to achieve various hair lengths. Please read this manual carefully before use to ensure proper installation and safe operation.

Figure 1: Remington SP-HC5000 Replacement Guide Combs. These combs are essential for precise hair cutting lengths.
2. Compatibility
The Remington SP-HC5000 Replacement Guide Combs are specifically designed for use with the following Remington Groom Innovation hair clipper models:
- HC5150
- HC5350
- HC5355
- HC5550
- HC5750
Ensure your hair clipper model is listed above for proper fit and function. Using these combs with incompatible models may result in improper attachment or damage to the clipper or combs.

Figure 2: Packaging of the SP-HC5000 combs, indicating compatible clipper models. Always verify compatibility before purchase and use.
3. Safety Information
Please observe the following safety precautions when using the guide combs with your hair clipper:
- Avoid Water: Do not use the hair clipper with attached combs near water or in wet environments.
- Adult Use Only: This product is not intended for use by children. Keep out of reach of children.
- Moving Blades: Exercise caution around the clipper's moving blades to prevent injury. Ensure the comb is securely attached before operating the clipper.
- Proper Cleaning: Follow the recommended cleaning and maintenance procedures for both the combs and the hair clipper to ensure hygiene and longevity.
- Inspect Before Use: Always inspect the guide combs for any damage or wear before each use. Do not use damaged combs.
4. Setup & Installation
To attach the guide comb to your Remington hair clipper:
- Ensure Clipper is Off: Before attaching or detaching any accessory, ensure your hair clipper is turned off and unplugged (if corded).
- Select Desired Comb: Choose the guide comb that corresponds to your desired hair cutting length. The combs are typically marked with length indicators (e.g., 3mm, 6mm, 9mm, 12mm, 18mm, 25mm).
- Align Comb: Position the guide comb over the clipper blade, aligning the comb's attachment points with the corresponding slots on the clipper head.
- Secure Attachment: Gently push the comb down until it clicks securely into place. Ensure it is firmly seated and does not wobble. Do not force the comb, as this may cause damage.
- Verify Attachment: Lightly tug on the comb to confirm it is securely attached before turning on the clipper.
To remove the guide comb, gently lift it from the clipper head, typically by pressing a release button or pulling it upwards from the back, depending on your specific clipper model. Refer to your clipper's main instruction manual for detailed attachment and removal procedures.

Figure 3: Guide combs with visible length markings. Select the appropriate comb for your desired hair length.
5. Operation
Once the guide comb is securely attached to your compatible Remington hair clipper:
- Power On: Turn on your hair clipper.
- Begin Trimming: Start trimming hair by moving the clipper against the direction of hair growth. Use smooth, even strokes.
- Check Length: Periodically check the hair length to ensure the desired result is being achieved.
- Clean During Use: If hair accumulates in the comb, turn off the clipper and remove the comb to clear the debris.
For detailed hair cutting techniques and tips, refer to the instruction manual provided with your Remington hair clipper.
6. Maintenance
Proper maintenance ensures the longevity and performance of your guide combs:
- Cleaning After Each Use: After each use, remove the guide comb from the clipper. Use a small brush (often supplied with the clipper) to remove any trapped hair from the comb and the clipper blades.
- Washing: The plastic guide combs can be rinsed under running water. Ensure they are completely dry before reattaching them to the clipper or storing them. Do not use harsh chemicals or abrasive cleaners.
- Storage: Store the guide combs in a clean, dry place, away from direct sunlight and extreme temperatures. Keep them protected from physical damage.
- Inspection: Regularly inspect the combs for any signs of wear, cracks, or broken teeth. Replace damaged combs immediately to prevent uneven cuts or potential injury.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Comb does not attach securely. | Incompatible clipper model, comb not aligned correctly, or comb/clipper attachment points are damaged. | Verify clipper model compatibility (Section 2). Realign the comb and push firmly until it clicks. Inspect comb and clipper for damage; replace if necessary. |
| Uneven hair cut. | Comb not securely attached, comb teeth are broken, or hair is accumulating in the comb. | Ensure comb is securely attached. Inspect comb for damage and replace if teeth are broken. Clean hair from the comb and clipper blades during use. |
| Comb feels loose during use. | Comb not fully engaged, or attachment mechanism is worn. | Re-attach the comb, ensuring it clicks into place. If the issue persists, the comb or clipper attachment may be worn and require replacement. |
8. Specifications
- Model: SP-HC5000
- Material: Plastic
- Color: Translucent Grey (as pictured)
- Compatible Clipper Models: HC5150, HC5350, HC5355, HC5550, HC5750
- Units: 2 Total (typically one large, one small)
9. Warranty & Support
For warranty information regarding your Remington SP-HC5000 Replacement Guide Combs, please refer to the warranty details provided with your original Remington hair clipper or visit the official Remington website. As an accessory, the warranty may be covered under the main product's terms or have a separate limited warranty.
For further assistance, technical support, or to purchase additional accessories, please contact Remington customer service or visit their official website:
- Remington Official Website: Remington-Europe.com
- Remington Brand Store: Amazon Remington Store





