1. Introduction
This manual provides comprehensive instructions for the proper use and maintenance of the Armstrong S-480 Commercial Floor Polish. Designed for resilient floors, this high-performance acrylic polish offers durability and a bright finish. Adhering to these guidelines will ensure optimal performance and longevity of your floor finish.

Figure 1: Front view of the Armstrong S-480 Commercial Floor Polish 1 Gallon container, showing the product label and branding.
2. Safety Information
Always read and understand all safety precautions before using this product. Failure to follow safety instructions may result in injury or damage.
- Eye Protection: Always wear appropriate eye protection, such as safety goggles, to prevent contact with eyes.
- Skin Protection: Wear protective gloves to avoid prolonged skin contact. Wash hands thoroughly after handling.
- Ventilation: Use in a well-ventilated area. If adequate ventilation is not available, use respiratory protection.
- Storage: Store in a cool, dry place, away from direct sunlight and freezing temperatures. Keep container tightly closed when not in use.
- Keep Out of Reach: Keep out of reach of children and pets.
- Disposal: Dispose of unused product and empty containers in accordance with local regulations.
3. Preparation and Setup
Proper preparation of the floor is crucial for optimal polish adhesion and finish quality.
- Clean the Floor: Thoroughly clean the floor surface to remove all dirt, grease, and old wax. Use a neutral floor cleaner designed for resilient floors. Rinse the floor completely with clean water to remove all cleaning solution residue.
- Strip if Necessary: If the floor has heavy build-up of old polish or wax, it may be necessary to strip the floor using an appropriate floor stripper. Follow the stripper manufacturer's instructions carefully.
- Allow to Dry: Ensure the floor is completely dry before applying the polish. Any moisture can negatively affect the polish's adhesion and finish.
- Room Temperature: Ensure the room temperature is between 60°F (15°C) and 80°F (27°C) for best results.
4. Operating Instructions (Application)
Follow these steps for effective application of Armstrong S-480 Commercial Floor Polish.
Initial Application:
- Shake Well: Gently shake the container before use to ensure the product is well-mixed.
- Apply Thin Coats: Pour a small amount of polish directly onto the clean, dry floor or into a clean mop bucket. Apply thin, even coats using a clean, synthetic mop or a suitable applicator. Avoid puddling.
- Drying Time: Allow each coat to dry for at least 30 minutes between applications. The polish should be dry to the touch before applying the next coat.
- Number of Coats: For optimal durability and gloss, apply 3 to 5 coats. More coats may be applied for higher gloss or in high-traffic areas.
Maintenance Application (Scrub and Recoat):
- Clean Surface: Regularly clean the floor with a neutral cleaner to remove dirt and scuff marks.
- Apply 1-2 Coats: After cleaning and drying, apply 1 or 2 thin coats of S-480 polish to restore gloss and protection.
High-Speed Buffing:
This polish can be buffed to achieve a high-gloss finish or for spray-buffing repairs.
- Ensure the polish is fully cured (typically 24-48 hours after final coat).
- Use a high-speed buffer with an appropriate buffing pad.
- For spray-buffing, lightly mist the area with a suitable spray-buff solution before buffing.

Figure 2: Back view of the Armstrong S-480 Commercial Floor Polish 1 Gallon container, displaying detailed application instructions and safety warnings.
5. Maintenance
Regular maintenance will preserve the appearance and protective qualities of your polished floor.
- Daily Cleaning: Dust mop or sweep daily to remove loose dirt and debris.
- Damp Mopping: Damp mop as needed with a neutral floor cleaner. Avoid harsh chemicals or abrasive cleaners that can dull or damage the polish.
- Spot Cleaning: Immediately clean spills to prevent staining or damage to the polish.
- Recoating: Periodically apply additional coats of S-480 polish as part of a scrub and recoat program to maintain gloss and protection, especially in high-traffic areas.
6. Troubleshooting
Common issues and their solutions when using Armstrong S-480 Commercial Floor Polish.
| Problem | Possible Cause | Solution |
|---|---|---|
| Dull or Streaky Finish |
|
|
| Poor Adhesion / Peeling |
|
|
| Yellowing |
|
|
7. Specifications
| Attribute | Detail |
|---|---|
| Product Name | Armstrong S-480 Commercial Floor Polish |
| Model Number | FBA_S-480 1GL |
| Brand | Armstrong |
| Volume | 1 Gallon (3.785 Liters) |
| Material Composition | Metal cross-linked acrylic copolymer emulsion |
| Coverage Rate | Approximately 1,500 to 2,000 square feet per gallon per coat |
| Recommended Use | Resilient floors (e.g., vinyl, linoleum, VCT) |
| Item Dimensions (L x W x H) | 6.2 x 6.2 x 12.2 inches |
| Item Weight | 8.35 pounds |
| UPC | 042369159500 |
8. Warranty and Support
For specific warranty information or technical support regarding Armstrong S-480 Commercial Floor Polish, please contact Armstrong customer service directly. Information regarding product data sheets and safety data sheets (SDS) can typically be found on the manufacturer's official website.
Manufacturer: Armstrong
Website: www.armstrongceilings.com (Note: This link is for Armstrong Ceilings, but it's the closest official Armstrong site found. Users should search for Armstrong Flooring or Commercial Products for direct support.)