1. Introduction and Overview
This manual provides detailed instructions for the installation, operation, and maintenance of your KOHLER 13468-CP Geometric Single-Hole Touchless AC-Powered Bathroom Sink Faucet. This faucet features advanced Insight™ adaptive infrared technology for hands-free operation, enhancing hygiene and convenience in your bathroom. The sensor intelligently calibrates upon installation to optimize performance and minimize false triggers.

Image: The KOHLER 13468-CP Geometric Touchless Faucet in Polished Chrome, showcasing its sleek design and integrated sensor.
2. Key Features
- Insight™ Adaptive Infrared Technology: Automatically adjusts the sensor for optimal performance upon installation.
- Waterproof Shroud: Protects electronic components from moisture, ensuring durability.
- Water-Saving 0.5 gpm Aerator: Designed to conserve water without compromising performance.
- AC-Powered: Provides reliable, continuous power for consistent operation.
- Temperature Control Handle Option: Allows for manual adjustment of water temperature.
3. Setup and Installation
Installation of the KOHLER 13468-CP faucet is designed for a single-hole lavatory sink. It requires an AC power source for operation. Please ensure you have access to a suitable power outlet and follow all local plumbing and electrical codes.
3.1 Pre-Installation Checklist
- Verify all components are present as per the packing list.
- Ensure the sink has a single faucet hole.
- Confirm access to an AC power supply (120V, 60Hz).
- Gather necessary tools: adjustable wrench, screwdriver, plumber's putty or silicone sealant.
3.2 Installation Steps
- Turn off Water Supply: Locate and turn off the hot and cold water supply valves under the sink.
- Remove Old Faucet: Disconnect water lines and mounting hardware from the existing faucet. Clean the sink surface.
- Install New Faucet: Place the new faucet body into the single hole on the sink. Secure it from underneath with the provided mounting hardware.
- Connect Water Lines: Attach the hot and cold water supply lines to the corresponding inlets on the faucet. Ensure connections are tight to prevent leaks.
- Connect AC Power: Connect the faucet's power cable to the AC power adapter, then plug the adapter into a grounded electrical outlet.
- Test Faucet: Turn on the water supply. Place your hands under the spout to activate the sensor. Check for leaks and proper water flow and temperature adjustment.
Note: For detailed diagrams and specific torque requirements, refer to the separate installation guide included in your product packaging. Professional installation is recommended if you are unfamiliar with plumbing or electrical work.
4. Operating Instructions
The KOHLER 13468-CP faucet operates using an infrared sensor for hands-free convenience. The temperature can be adjusted manually using the side handle.
4.1 Activating Water Flow
- Simply place your hands within the sensor's detection zone under the spout.
- Water will begin to flow automatically.
- Remove your hands from the detection zone, and the water flow will stop.
4.2 Adjusting Water Temperature
- The faucet features a temperature control handle, typically located on the side of the faucet body.
- Move the handle to the left for hotter water and to the right for colder water.
- The selected temperature will be maintained for subsequent sensor activations until manually changed.
5. Maintenance
Regular cleaning and maintenance will ensure the longevity and optimal performance of your KOHLER touchless faucet.
5.1 Cleaning the Faucet
- Use a soft, damp cloth and mild soap to clean the faucet's exterior.
- Avoid abrasive cleaners, harsh chemicals, or scouring pads, as these can damage the finish.
- For polished chrome finishes, wipe dry immediately after cleaning to prevent water spots.
5.2 Sensor Care
- Keep the sensor window (located on the faucet body) clean and free of obstructions.
- Wipe the sensor window gently with a soft cloth if it appears dirty or if the faucet's response becomes inconsistent.
5.3 Aerator Cleaning
- If water flow decreases, the aerator may be clogged.
- Unscrew the aerator from the spout tip.
- Rinse any debris from the aerator screen under running water.
- Reinstall the aerator, ensuring it is securely tightened.
6. Troubleshooting
If you encounter issues with your faucet, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| No water flow | Water supply turned off; Power disconnected; Sensor obstructed; Aerator clogged. | Check water supply valves; Ensure AC adapter is plugged in; Clean sensor window; Clean aerator. |
| Inconsistent sensor activation | Sensor window dirty; Reflective surfaces nearby; Low ambient light. | Clean sensor window; Remove reflective objects; Ensure adequate lighting. |
| Low water pressure/flow | Aerator clogged; Water supply valves not fully open. | Clean aerator; Fully open water supply valves. |
| Water temperature issues | Temperature control handle incorrectly set; Hot/cold water supply issues. | Adjust temperature handle; Check hot/cold water supply to the house. |
If these steps do not resolve the issue, please contact Kohler customer support.
7. Specifications
| Specification | Detail |
|---|---|
| Brand | Kohler |
| Model Number | 13468-CP |
| Model Name | Geometric |
| Color | Polished Chrome |
| Material | Metal (Stainless Steel Handle) |
| Mounting Type | Deck Mount |
| Hole Count | 1 |
| Number of Handles | 1 (for temperature control) |
| Spout Height | 4.19 Inches |
| Spout Reach | 5.31 Inches |
| Item Weight | 16 ounces |
| Special Feature | Water Resistant |
| Power Source | AC-Powered |
| Flow Rate | 0.5 gallons per minute (gpm) |
| UPC | 650531917409 |
8. Warranty and Support
Your KOHLER 13468-CP Geometric Touchless Faucet is covered by a Five-Year Limited Manufacturer Warranty. This warranty covers defects in material and workmanship under normal use and service. For specific terms and conditions, or to make a warranty claim, please refer to the warranty documentation included with your product or visit the official Kohler website.
For technical assistance, troubleshooting beyond this manual, or to order replacement parts, please contact Kohler Customer Service:
- Website: www.kohler.com
- Phone: Refer to your product packaging for regional contact numbers.