Prier P-164D04

Prier P-164D04 Quarter-Turn Frost Free Anti-Siphon Outdoor Hydrant User Manual

Model: P-164D04

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Prier P-164D04 Quarter-Turn Frost Free Anti-Siphon Outdoor Hydrant. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product. The Prier P-164D04 is designed for reliable outdoor water access, featuring frost-free and anti-siphon capabilities to protect your plumbing system.

2. Safety Information

Always observe the following safety precautions to reduce the risk of injury or property damage:

  • Professional Installation Recommended: Installation of this hydrant may require specialized plumbing knowledge. If you are not an experienced DIY individual, it is highly recommended to consult a qualified plumber for installation to prevent potential water damage or improper function.
  • Water Shut-Off: Always turn off the main water supply before attempting any installation, maintenance, or repair on the hydrant.
  • Pressure Relief: After shutting off the water supply, open a nearby faucet to relieve any residual water pressure in the lines.
  • Winterization: Disconnect all hoses from the hydrant before freezing temperatures occur to prevent damage to the hydrant and your plumbing system. Failure to do so can lead to freezing and bursting of the hydrant or pipes.
  • Chemicals: Do not use harsh chemicals or abrasive cleaners on the hydrant's exterior finish.
  • Proposition 65 Warning: This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

3. Product Overview

The Prier P-164D04 is a heavy-duty, quarter-turn frost-free anti-siphon outdoor hydrant. It is constructed from brass, copper tubing, stainless steel, and aluminum components, designed for durability and reliable performance in various weather conditions. Its frost-free design allows the valve seat to be located inside the heated portion of the structure, preventing freezing.

Prier P-164D04 Quarter-Turn Frost Free Anti-Siphon Outdoor Hydrant with dimensions

Figure 1: Prier P-164D04 Hydrant showing overall dimensions. The hydrant measures approximately 10 inches (24 cm) in total length, with the main body and handle visible, and a copper pipe extending downwards.

Key Features:

  • Quarter-Turn Operation: Provides quick and easy control of water flow.
  • Frost-Free Design: The valve closes inside the heated wall, preventing water from freezing in the pipe exposed to cold.
  • Anti-Siphon (Vacuum Breaker): Prevents contaminated water from being siphoned back into the potable water supply.
  • Durable Construction: Made with heavy brass, copper tubing, stainless steel, and aluminum for long-lasting performance.
  • Inlet/Outlet: 1/2" MIP x 1/2" SWT connections.
  • Length: 4-inch length, designed to connect within the heated portion of a structure.

4. Setup & Installation

Proper installation is crucial for the frost-free and anti-siphon features to function correctly. If you are unsure about any step, consult a professional plumber.

Tools and Materials Required:

  • Pipe wrench or adjustable wrench
  • Pipe cutter (if modifying existing plumbing)
  • Soldering equipment (torch, solder, flux, steel brush) if using sweat connections
  • Thread sealant tape or pipe dope (for threaded connections)
  • Drill and appropriate bits (for mounting)
  • Mounting screws/anchors

Installation Steps:

  1. Prepare the Location: Select an exterior wall location where the hydrant's inlet can connect to a water supply line within the heated portion of your structure. The 4-inch length of this hydrant is designed for standard wall depths.
  2. Shut Off Water Supply: Locate your main water shut-off valve and turn off the water supply to your home. Open a nearby faucet to drain the lines and relieve pressure.
  3. Create Wall Opening: If installing in a new location, carefully create an opening in the exterior wall for the hydrant body and a corresponding opening in the interior wall to access the water supply line.
  4. Connect to Water Supply:
    • The hydrant features 1/2" MIP (Male Iron Pipe) x 1/2" SWT (Sweat) connections.
    • For threaded connections, apply thread sealant tape or pipe dope to the male threads of the water supply line. Carefully thread the hydrant onto the supply line, ensuring a tight, leak-free connection.
    • For sweat connections, ensure surfaces are clean. Apply flux to both the hydrant's sweat connection and the copper supply pipe. Solder the connection according to standard plumbing practices. Note: If soldering, disassemble the hydrant first to protect internal rubber seals from heat damage.
  5. Position and Secure: Ensure the hydrant is properly angled for drainage when shut off. Mount the hydrant securely to the exterior wall using appropriate screws and anchors.
  6. Restore Water Supply: Slowly turn the main water supply back on. Check all connections for leaks.
  7. Test Operation: Turn the hydrant handle to the open position and check for water flow. Turn it off and ensure the flow stops completely.

5. Operating Instructions

The Prier P-164D04 hydrant features a simple quarter-turn operation for water control.

  • To Open: Turn the handle approximately 90 degrees (a quarter-turn) counter-clockwise to open the valve and allow water to flow.
  • To Close: Turn the handle approximately 90 degrees (a quarter-turn) clockwise to close the valve and stop water flow. Ensure the handle is fully turned to the closed position to engage the frost-free feature and prevent drips.
  • Anti-Siphon Feature: The integrated anti-siphon (vacuum breaker) mechanism prevents backflow of non-potable water into your drinking water supply. This device operates automatically.

6. Maintenance

Regular maintenance ensures the longevity and proper function of your Prier hydrant.

  • Winterization: Before the first freeze of the season, it is critical to disconnect all hoses, splitters, and other attachments from the hydrant. This allows any residual water in the hydrant's spout to drain completely, activating the frost-free mechanism and preventing freezing damage.
  • Cleaning: Clean the exterior of the hydrant with a soft cloth and mild soap and water. Avoid abrasive cleaners or pads that could damage the finish.
  • Leak Checks: Periodically inspect the hydrant for any signs of leaks, especially at connection points. Address any leaks promptly to prevent water damage.
  • Vacuum Breaker Inspection: The anti-siphon device (vacuum breaker) is designed to prevent backflow. If you notice constant dripping from the vacuum breaker cap or water not flowing correctly, it may require inspection or replacement.

7. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
No water flow when open
  • Main water supply is off.
  • Hydrant valve not fully open.
  • Anti-siphon feature in locked position (initial use).
  • Obstruction in the line or hydrant.
  • Ensure main water supply is on.
  • Turn handle fully counter-clockwise.
  • Connect to a temporary water line and open to allow the anti-siphon to reset.
  • Inspect for blockages. If persistent, professional assistance may be required.
Water drips from spout when closed
  • Valve not fully closed.
  • Worn washer or seal.
  • Hose or attachment still connected in freezing weather.
  • Ensure handle is fully turned clockwise.
  • A rebuild kit may be needed. Consult a plumber.
  • Disconnect all hoses and attachments.
Water leaks from vacuum breaker cap
  • Normal operation (briefly) when water is shut off.
  • Damaged vacuum breaker.
  • Backpressure from kinked hose or nozzle.
  • If dripping is constant, the vacuum breaker may need replacement.
  • Ensure hoses are not kinked and nozzles do not create excessive backpressure.
Hydrant freezes in cold weather
  • Hose or attachment left connected.
  • Improper installation (valve seat not in heated area).
  • Always disconnect hoses before freezing temperatures.
  • Verify the hydrant's valve seat is correctly positioned within the heated wall space. Re-installation may be necessary.

8. Specifications

Model NumberP-164D04
BrandPrier
MaterialBrass, Copper, Stainless Steel, Aluminum
Length4 inches
Inlet Connection Size0.5 Inches (1/2" MIP x 1/2" SWT)
Outlet Connection Size0.5 Inches (1/2" MIP x 1/2" SWT)
Exterior FinishStainless Steel (Satin Nickel Plated)
Item Dimensions (L x W x H)4 x 3 x 0.5 inches (Product dimensions)
Item Weight1.1 pounds
Specification MetNSF, ASSE, Frost-Free Compliance
Number of Handles1
Mounting TypeWall

9. Warranty & Support

For specific warranty information and customer support, please refer to the official Prier website or contact Prier customer service directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Standard Plumbing Supply

Contact Information: Please visit www.prier.com for the most up-to-date contact details and support resources.

© 2024 Prier. All rights reserved.