Johnson Controls A19ADB-2

Johnson Controls A19ADB-2 Direct Immersion Temperature Controller User Manual

Model: A19ADB-2

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Johnson Controls A19ADB-2 Direct Immersion Temperature Controller. This device is designed for precise temperature regulation in various industrial and scientific applications, specifically within a 100/240°F range. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read and understand these instructions completely before proceeding.

  • Always disconnect power before servicing the unit to prevent electrical shock.
  • Ensure all wiring complies with local and national electrical codes.
  • Installation should only be performed by qualified personnel.
  • Do not exceed the specified electrical ratings of the device.
  • Protect the device from moisture and extreme temperatures outside its operating range.

3. Product Overview

The Johnson Controls A19ADB-2 is a direct immersion temperature controller designed for applications requiring precise temperature sensing and control. It features a robust housing and an immersion bulb for direct contact with the medium being controlled. The unit is capable of operating within a temperature range of 100°F to 240°F.

Johnson Controls A19ADB-2 Direct Immersion Temperature Controller with a gray housing and a copper immersion bulb extending from the side. A black adjustment knob is visible on the top surface.

Figure 1: Johnson Controls A19ADB-2 Direct Immersion Temperature Controller. This image shows the main unit with its gray protective casing, a visible adjustment dial on the top, and the copper immersion bulb extending from the right side, designed for direct contact with the controlled medium.

Key Features:

  • Direct immersion sensing for accurate temperature measurement.
  • Adjustable setpoint within 100°F to 240°F range.
  • Durable construction suitable for industrial environments.
  • Open-high (m/r open-hi) contact configuration.

4. Setup and Installation

Installation of the A19ADB-2 controller requires careful attention to detail and adherence to safety protocols. It is recommended that installation be performed by a certified technician.

4.1 Mounting the Controller

  1. Select a suitable location for mounting the controller, ensuring it is easily accessible for adjustments and maintenance, and protected from excessive vibration or physical damage.
  2. Ensure the immersion bulb can be fully submerged in the medium whose temperature is to be controlled.
  3. Securely fasten the controller housing using appropriate mounting hardware.

4.2 Electrical Wiring

CAUTION: Disconnect all power before making electrical connections.

  • Refer to the wiring diagram provided with the unit (not included in this general manual) for specific connection points.
  • Connect the power supply wires to the designated terminals.
  • Connect the load wires (e.g., to a heater or cooling element) to the appropriate control terminals.
  • Ensure all connections are tight and secure to prevent loose contacts and potential hazards.

5. Operating Instructions

Once installed and wired, the A19ADB-2 controller is ready for operation.

5.1 Setting the Temperature Setpoint

  1. Locate the adjustment knob on the top of the controller housing (refer to Figure 1).
  2. Rotate the knob to align the desired temperature with the indicator mark. The temperature range is 100°F to 240°F.
  3. The controller will now maintain the temperature of the immersed medium at or around the setpoint.

5.2 Understanding Control Action

The A19ADB-2 features an "open-high" (m/r open-hi) contact configuration. This typically means the control contacts open when the sensed temperature rises above the setpoint, and close when the temperature falls below the setpoint. This action is suitable for applications where the controlled device (e.g., a heater) needs to be turned off when the temperature is too high.

6. Maintenance

The Johnson Controls A19ADB-2 is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and accuracy.

  • Cleaning: Keep the exterior of the controller clean and free from dust and debris. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Connections: Periodically inspect electrical connections for tightness and signs of corrosion.
  • Immersion Bulb: Ensure the immersion bulb is clean and free from buildup that could affect temperature sensing accuracy.
  • Calibration: While the unit is factory calibrated, if precise accuracy is critical and deviations are suspected, professional recalibration may be required.

7. Troubleshooting

This section provides solutions to common issues encountered with the A19ADB-2 temperature controller.

ProblemPossible CauseSolution
Controller not respondingNo power supply; Loose wiring; Blown fuse/tripped breaker.Check power connections; Verify wiring integrity; Reset breaker/replace fuse.
Inaccurate temperature readingImmersion bulb not fully immersed; Buildup on bulb; Controller out of calibration.Ensure full immersion; Clean the bulb; Contact service for recalibration.
Temperature fluctuates widelyImproper setpoint; External environmental factors; Controller malfunction.Adjust setpoint; Shield from drafts/heat sources; Contact service if malfunction suspected.

If troubleshooting steps do not resolve the issue, contact Johnson Controls technical support or a qualified service technician.

8. Specifications

AttributeDetail
ModelA19ADB-2
BrandJohnson Controls
Temperature Range100°F to 240°F
Control ActionOpen-High (m/r open-hi)
TypeDirect Immersion Temperature Controller
National Stock Number5930-01-424-8404
ManufacturerJohnson Controls, Inc.

9. Warranty and Support

For specific warranty information regarding your Johnson Controls A19ADB-2, please refer to the documentation included with your purchase or visit the official Johnson Controls website. For technical support, service, or parts, please contact Johnson Controls customer service directly.

Contact Information: Please refer to the official Johnson Controls website for the most current contact details.

© 2023 Johnson Controls. All rights reserved. Information subject to change without notice.