Fischer 117.01

Fischer 117.01 Bimetallic Thermometer Instruction Manual

1. Introduction

Thank you for choosing the Fischer 117.01 Bimetallic Thermometer. This precision instrument is designed for accurate temperature measurement in both indoor and outdoor environments. Crafted from high-quality stainless steel, it offers durability and a clear analog display for easy readability. This manual provides essential information for the proper setup, operation, and maintenance of your thermometer.

2. Safety Information

  • This thermometer is not a toy. Keep it out of reach of children.
  • Handle the device with care to avoid damage to the casing or internal mechanism.
  • Do not expose the thermometer to extreme physical impact or excessive force.
  • Avoid disassembling the unit, as this may impair its accuracy and void any potential warranty.

3. Product Overview

The Fischer 117.01 thermometer features a robust stainless steel casing and a clear dial with a bimetallic sensor for temperature readings. Its compact design makes it suitable for various placements.

Front view of the Fischer 117.01 Bimetallic Thermometer, showing the white dial with temperature markings from -30 to 50 degrees Celsius and a black needle.

Figure 3.1: Front view of the Fischer 117.01 Bimetallic Thermometer.

Angled view of the Fischer 117.01 Bimetallic Thermometer, highlighting the stainless steel casing and the clear temperature dial.

Figure 3.2: Angled view, showcasing the thermometer's profile.

Side view of the Fischer 117.01 Bimetallic Thermometer, showing the depth of the stainless steel casing and ventilation slots.

Figure 3.3: Side view, illustrating the thermometer's depth.

Back view of the Fischer 117.01 Bimetallic Thermometer, showing the wall mounting hole at the top and several small ventilation holes.

Figure 3.4: Back view, indicating the wall mounting point.

4. Setup

The Fischer 117.01 thermometer is designed for easy wall mounting.

  1. Choose a Location: Select a suitable location for mounting. For accurate readings, avoid direct sunlight, drafts, or proximity to heat sources (e.g., radiators, air conditioning vents) that could influence the temperature measurement.
  2. Mounting: Use a small screw or nail to secure the thermometer to a wall. The back of the thermometer features a dedicated mounting hole for this purpose (refer to Figure 3.4). Ensure the thermometer is securely fastened and level.
  3. Stabilization: Allow the thermometer approximately 60 seconds to stabilize and display the current ambient temperature after mounting or relocation.

5. Operating Instructions

The Fischer 117.01 is an analog bimetallic thermometer that operates without external power. It continuously displays the ambient temperature.

  • Reading Temperature: The black needle on the dial indicates the current temperature in degrees Celsius (°C).
  • Measurement Range: The thermometer measures temperatures within a range of -35 °C to 55 °C.
  • Accuracy: The measurement precision is approximately +/- 1 °C.
  • Graduation: The dial is marked with 1-degree increments for clear readings.

6. Maintenance

Maintaining your Fischer thermometer is simple and ensures its longevity and accuracy.

  • Cleaning: To clean the thermometer, simply wipe it with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the stainless steel finish or the dial.
  • Storage: If storing the thermometer for an extended period, keep it in a dry place away from extreme temperatures and direct sunlight.

7. Troubleshooting

If you encounter issues with your thermometer, consider the following:

  • Inaccurate Readings: If you suspect inaccurate readings, verify that the thermometer is not placed in direct sunlight, near a heat source, or in a drafty area. Relocate it to a more stable environment and allow time for stabilization.
  • No Movement: Ensure the thermometer is not obstructed. If the needle remains static, gently tap the casing. If the issue persists, the internal mechanism may be damaged.

8. Specifications

FeatureSpecification
Model Number117.01
BrandFischer
Dimensions (L x W x H)30 x 10.3 x 10 cm (approx. 103 mm diameter)
Weight78 grams
MaterialStainless Steel
Measurement Range-35 °C to 55 °C
Measurement Accuracy+/- 1 °C
Graduation1 °C
Response TimeApprox. 60 seconds
Display TypeAnalog
Power SourceNone
UsageIndoor and Outdoor
OriginMade in Germany

9. Warranty and Support

Fischer instruments are known for their quality and precision, with a manufacturing heritage in Germany since 1945. Each instrument undergoes careful testing.

For specific warranty information or technical support, please refer to the documentation provided at the time of purchase or contact the manufacturer directly. The seller for this product is Feingerätebau K. Fischer GmbH.

For further assistance, you may visit the official Fischer website or contact their customer service department.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.