Graham-Field 3932-716
Graham-Field Latex Tubing User Manual
Model: 3932-716 | Brand: Graham-Field
Product Overview
This manual provides essential information for the proper use, setup, and maintenance of the Graham-Field 3933 38 Latex Tubing. This product is designed for various applications requiring flexible, seamless, and sterilizable tubing.

Image: Graham-Field 3933 38 Latex Tubing, amber colored, wound neatly on a white dispenser reel. The tubing is smooth and consistent in diameter.
Key Features
- Applications: Suitable for medical, dental, exercise, therapy, general laboratory, and food/beverage uses.
- Seamless Design: Free of striations in the lumen, ensuring clear passage for liquids and gases.
- Sterilizable: Can be sterilized for hygienic applications.
- Dispenser Reel: Supplied on a convenient dispenser reel for easy handling and storage.
- Length: Provided in a 50-foot roll, which may consist of up to 3 random lengths.
- Origin: Manufactured in the USA.
Specifications
| Specification | Detail |
|---|---|
| Inner Diameter (ID) | 3/16 inches |
| Outer Diameter (OD) | 3/8 inches |
| Wall Thickness | 3/32 inches (Nominal: 0.25 inch) |
| Length | 50 feet (in up to 3 random lengths) |
| Material | Natural Rubber (Latex), Polyisoprene Rubber |
| Color | Amber |
| Performance Characteristics | Elasticity, Translucency and uniformity of color, Gripping power |
| Compliance | Meets requirements of A-A-52047 type 1, 3, 4, & 5 and A-A-53848 |
| Model Number | 3932-716 |
| UPC | 882985913755 |
Setup and Installation
The Graham-Field Latex Tubing is provided on a dispenser reel for ease of use. Follow these general guidelines for setup:
- Unpacking: Carefully remove the tubing reel from its packaging.
- Inspection: Before use, visually inspect the tubing for any signs of damage, kinks, or irregularities. Do not use if damage is observed.
- Cutting: If a specific length is required, use a sharp, clean cutting tool to ensure a straight, burr-free cut. This helps maintain the integrity of the tubing and prevents blockages or leaks.
- Connection: When connecting to fittings or other components, ensure a snug and secure fit to prevent leaks or disconnections during operation.
- Routing: Route the tubing in a manner that avoids sharp bends, excessive tension, or abrasion against surfaces. This prolongs the life of the tubing and ensures proper flow.
Operating Guidelines
This latex tubing is designed for a variety of applications. Adhere to the following guidelines for optimal performance:
- Application Suitability: Ensure the tubing is suitable for the specific liquid or gas being transported and the environmental conditions (temperature, pressure).
- Temperature Range: Avoid exposing the tubing to extreme temperatures outside its intended operating range, as this can affect its elasticity and integrity.
- Pressure Limits: Do not exceed the pressure limits for which the tubing is designed. Over-pressurization can lead to rupture.
- Chemical Compatibility: Verify chemical compatibility if the tubing will be in contact with substances other than water or air. Latex can degrade when exposed to certain chemicals.
- Flow Monitoring: Regularly monitor the flow through the tubing to ensure there are no obstructions or kinks affecting performance.
Maintenance and Sterilization
Proper maintenance and sterilization are crucial for extending the life of the tubing and ensuring hygienic use, especially in medical and food/beverage applications.
- Cleaning: Clean the tubing regularly with appropriate cleaning agents compatible with latex. Rinse thoroughly with distilled or deionized water.
- Sterilization: The tubing is sterilizable. Common methods include autoclaving (steam sterilization) or chemical sterilization. Follow established protocols for the chosen method. Ensure the tubing is completely dry before storage after sterilization.
- Storage: Store the tubing in a cool, dry place away from direct sunlight, ozone, and extreme temperatures. Prolonged exposure to light and heat can degrade latex. Keep it on the dispenser reel to prevent kinking.
- Inspection: Periodically inspect the tubing for signs of wear, cracking, discoloration, or loss of elasticity. Replace tubing that shows signs of degradation.
Troubleshooting
This section addresses common issues that may arise during the use of the latex tubing.
- Reduced Flow:
- Check for Kinks: Ensure the tubing is not kinked or bent sharply.
- Check for Obstructions: Inspect the lumen for any blockages or debris.
- Verify Connections: Ensure all connections are secure and not restricting flow.
- Leaks at Connections:
- Tighten Connections: Ensure fittings are securely tightened.
- Inspect Tubing Ends: Check for cuts or damage at the tubing ends. Recut if necessary.
- Verify Fitting Compatibility: Ensure the fittings are the correct size and type for the tubing.
- Tubing Degradation (Cracking, Discoloration):
- Review Storage Conditions: Ensure tubing is stored away from direct sunlight, heat, and ozone.
- Check Chemical Exposure: Verify compatibility with any chemicals it has come into contact with.
- Replace Tubing: If degradation is significant, replace the tubing to ensure safety and performance.
Warranty and Support
Specific warranty information for the Graham-Field 3933 38 Latex Tubing is not provided in this manual. For details regarding product warranty, technical support, or service inquiries, please contact Graham-Field directly through their official website or customer service channels.
Note: Always refer to the manufacturer's official documentation or website for the most current and detailed warranty and support information.