Watt Stopper BZ-50

Wattstopper BZ-50 Occupancy Sensor Control Switch Pack User Manual

Model: BZ-50

1. Introduction

The Wattstopper BZ-50 is a robust power pack designed to provide power and switching capabilities for low voltage occupancy sensors and other control devices. It facilitates automatic and manual control of lighting and other electrical loads, operating across 120V, 230V, and 277V systems with a 20 Amp capacity. This manual provides essential information for the safe installation, operation, and maintenance of your BZ-50 unit.

2. Safety Information

WARNING: RISK OF ELECTRIC SHOCK. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes. Disconnect power at the circuit breaker or fuse before installing or servicing. Failure to follow these instructions may result in serious injury or death.

  • Ensure the power supply is completely disconnected before any wiring or maintenance.
  • Do not exceed the specified voltage and current ratings of the device.
  • Use appropriate wire gauges for connections as per electrical codes.
  • This device is intended for indoor use only.

3. Key Features

  • Automatic or manual switching options for connected loads.
  • Simple retrofit installation and operation; no Neutral needed for certain configurations.
  • Shutoff warning with optional audible beep during grace period before automatic deactivation.
  • Pushbutton functionality allows overriding automatic shutoff events.
  • Supports multi-way operation for 3- and 4-way switching systems.

4. Setup and Installation

The BZ-50 power pack is designed for easy retrofit installation. Refer to the wiring diagram provided with the product packaging for specific connection details. Ensure all connections are secure and properly insulated.

Wattstopper BZ-50 Power Pack with Wiring

Image: Wattstopper BZ-50 Power Pack with Wiring
This image shows the Wattstopper BZ-50 power pack with its various colored wires for connection. The unit features a compact design with ventilation holes on the top surface, indicating its electrical nature and need for proper air circulation.

4.1 Wiring Connections

Connect the BZ-50 to the appropriate power supply and load circuits. The unit is compatible with 120V, 230V, and 277V systems. Ensure the current rating of 20 Amps is not exceeded. The BZ-50 can be integrated into multi-way switching setups, allowing for flexible control configurations.

5. Operating Instructions

The BZ-50 offers both automatic and manual control modes for connected loads.

5.1 Automatic Control

In automatic mode, the unit responds to signals from connected occupancy sensors or other lighting control systems to turn loads on or off. The BZ-50 acts as the relay, switching power to the connected devices based on the input signals.

5.2 Manual Control and Override

For manual control, users can directly operate the connected loads via a pushbutton or switch connected to the BZ-50. A shutoff warning, which can include an optional audible beep, precedes the automatic shutoff event, providing a grace period. The pushbutton on the device allows for overriding an automatic shutoff event, keeping the loads active even if the sensor detects no occupancy.

6. Maintenance

The Wattstopper BZ-50 is designed for maintenance-free operation under normal conditions. To ensure optimal performance and longevity:

  • Keep the unit free from excessive dust and debris.
  • Periodically inspect all wiring connections to ensure they remain secure.
  • Do not attempt to open or repair the unit yourself; refer servicing to qualified personnel.

7. Troubleshooting

If you encounter issues with your BZ-50, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Loads do not turn on/off automatically.No power to BZ-50, faulty sensor connection, incorrect sensor settings.Verify power supply to the BZ-50. Check wiring to the occupancy sensor. Ensure sensor is configured correctly.
Loads do not respond to manual pushbutton.Incorrect wiring to pushbutton, faulty pushbutton.Inspect pushbutton wiring. Test pushbutton functionality.
Unit is not receiving power.Circuit breaker tripped, loose wiring connection.Check circuit breaker and reset if tripped. Verify all power connections are secure.
Audible beep warning is not functioning.Feature disabled, internal fault.Consult the full product documentation for configuration options. If issue persists, contact support.

8. Specifications

SpecificationDetail
BrandWatt Stopper
ModelBZ-50
Power SourceCorded Electric
Mounting TypePanel Mount or Chassis Mount
Current Rating20 Amps
Voltage Compatibility120V, 230V, 277V
Maximum Frequency60 Hz
Item Weight1.6 ounces
Specification MetUL
UPC754182922901, 696504768753
Global Trade Identification Number00754182922901
ManufacturerWATTSTOPPER

9. Warranty and Support

For warranty information, technical assistance, or to inquire about replacement parts, please contact Watt Stopper customer service. Keep your purchase receipt and product serial number handy for any warranty claims. Detailed contact information can typically be found on the manufacturer's official website or product packaging.

Wattstopper BZ-50 Product Packaging

Image: Wattstopper BZ-50 Product Packaging
This image displays the brown cardboard packaging for the Wattstopper BZ-50 Power Pack. The label clearly indicates 'WattStopper', 'Cat. No. BZ-50', 'Power Pack', '120/230/277V, 50/60Hz', and 'Made in China'. A UL certification mark and UPC barcode are also visible.

© 2024 Watt Stopper. All rights reserved.

Related Documents - BZ-50

Preview Wattstopper DT-205 Dual Technology Occupancy Sensor Installation and Operation Manual
Comprehensive guide for installing, wiring, adjusting, and troubleshooting the Wattstopper DT-205 Dual Technology Low Voltage Occupancy Sensor. Features PIR and ultrasonic detection for efficient lighting control.
Preview WattStopper BZ-150 Power Pack Installation Instructions
Comprehensive installation and operation guide for the WattStopper BZ-150 Power Pack, featuring wiring instructions, specifications, and troubleshooting steps for lighting control systems.
Preview WattStopper BZ-200, BZ-250, BZ-250-347 Power Pack Installation Instructions
Installation and operation guide for WattStopper BZ-200, BZ-250, and BZ-250-347 power packs. Includes wiring diagrams, specifications, and troubleshooting.
Preview Wattstopper BZ-250 Lighting and Plug Load Flex Control Power Pack - Product Datasheet
Detailed product datasheet for the Wattstopper BZ-250 Power Pack, featuring high-efficiency switching, Auto-On/Manual-On operation, Hold-On/Hold-Off inputs, and plenum-rated design for lighting and plug load control. Includes specifications, installation guidance, and application scenarios.
Preview Wattstopper DSW-302 Dual Technology Dual Relay Wall Switch Occupancy Sensor - Product Data
Detailed datasheet for the Wattstopper DSW-302, a dual technology dual relay wall switch occupancy sensor. Features include PIR and ultrasonic detection, dual relay control, various wiring options, and comprehensive specifications for energy efficiency and lighting control.
Preview WattStopper FSP-201B Series PIR Fixture Integrated Outdoor Sensor Installation Guide
Installation guide for WattStopper FSP-201B PIR fixture integrated outdoor sensors. Covers specifications, installation, wiring, configuration, and troubleshooting for IP66 rated lighting control solutions.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.