1. Introduction
This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your Edlund MSR-2000 Metric Portion Scale. Designed for precision and durability, this mechanical dial scale offers accurate metric measurements for various applications. Please read this manual thoroughly before using the scale to ensure safe and efficient operation.

Figure 1: Edlund MSR-2000 Metric Portion Scale. This image shows the front view of the scale, highlighting its rotating dial and robust stainless steel construction, designed for precise metric portioning.
2. Product Features
- Type: Metric Portion Scale, Dial Type
- Capacity: 2000 grams (2 kg)
- Graduation: 10 gram increments
- Construction: Durable Stainless Steel
- Design: Top loading counter model with a rotating dial for easy zeroing
- Cleaning: Dishwasher safe (when front window is removed)
- Certification: NSF certified
3. Safety Information
Adhere to the following safety guidelines to prevent injury or damage to the scale:
- Do not exceed the maximum weight capacity of 2000 grams. Overloading can damage the internal mechanism.
- Place the scale on a stable, level surface to ensure accurate readings.
- Avoid dropping the scale or subjecting it to severe impacts.
- Keep the scale away from extreme temperatures and direct heat sources.
- Ensure the front window is properly removed before placing the scale in a dishwasher.
4. Setup
- Unpacking: Carefully remove the scale from its packaging. Inspect for any signs of damage during transit.
- Placement: Position the scale on a firm, flat, and level surface. Uneven surfaces can affect accuracy.
- Initial Zeroing: Before first use, ensure the dial is set to zero. If not, gently rotate the dial until the indicator aligns with the '0' mark.
5. Operation
- Prepare the Scale: Ensure the scale is clean and the dial is set to zero. If using a container for weighing, place the empty container on the scale first.
- Tare (Zeroing with Container): If using a container, gently rotate the dial until the indicator aligns with the '0' mark again. This will subtract the weight of the container.
- Weighing: Carefully place the item to be weighed onto the scale platform or into the tared container.
- Read Measurement: Read the weight indicated by the pointer on the rotating dial. The scale measures in 10-gram increments up to 2000 grams.
- Remove Item: Once the measurement is taken, remove the item from the scale. The dial should return to zero (or the tared container's weight).
6. Maintenance and Cleaning
General Cleaning
- Wipe the exterior of the scale with a damp cloth and mild detergent.
- Avoid using abrasive cleaners or scouring pads, as these can scratch the stainless steel finish.
- Dry thoroughly after cleaning.
Dishwasher Cleaning
The Edlund MSR-2000 is dishwasher safe, provided the front window is removed.
- Remove Front Window: Carefully detach the front window of the dial. Refer to the product diagram for specific removal instructions if needed.
- Place in Dishwasher: Place the scale body (without the front window) in the dishwasher.
- Wash Cycle: Use a standard wash cycle.
- Reassemble: After cleaning and drying, reattach the front window securely before using the scale.
7. Troubleshooting
- Inaccurate Readings:
- Ensure the scale is on a level, stable surface.
- Check if the dial is properly zeroed before weighing.
- Verify that the weight limit of 2000 grams is not exceeded.
- Dial Not Moving Freely:
- Check for any obstructions under or around the platform.
- Ensure the scale is clean and free of debris.
- Scale Does Not Zero:
- Gently rotate the dial to manually adjust to zero. If it consistently fails to hold zero, the scale may require professional service.
8. Specifications
| Brand | Edlund |
| Model Number | MSR-2000 (42800) |
| Weight Capacity | 2000 grams (2 kg) |
| Graduation | 10 grams |
| Material | Stainless Steel |
| Form Factor | Mini, Top Loading Counter Model |
| Item Weight | Approximately 5 pounds (2.27 kg) |
| Package Dimensions | Approximately 10 x 10 x 10 inches |
| Certifications | NSF Certified |
9. Warranty and Support
Warranty Information
The Edlund MSR-2000 Metric Portion Scale comes with a 1-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, abuse, accidents, unauthorized repairs, or normal wear and tear.
Customer Support
For warranty claims, technical assistance, or inquiries regarding your Edlund MSR-2000 scale, please contact Edlund customer service directly. Refer to the contact information provided with your product packaging or visit the official Edlund website for current support details.