Introduction

This manual provides essential information for the safe and effective use of your Philips MHC150/U/MP/3K Alto 150W Clear ED17 Protected Warm White Metal Halide Bulb. Please read this manual thoroughly before installation and operation, and retain it for future reference.

Important Safety Information

WARNING: Risk of electric shock. Risk of fire. Risk of burns.

  • Always turn off power and allow the bulb to cool before inspecting, installing, or removing.
  • Do not use if outer envelope is broken or scratched.
  • Use only in fixtures designed for metal halide lamps with appropriate ballast and enclosed luminaire.
  • This bulb operates at high temperatures. Avoid contact with the bulb during operation and immediately after shutdown.
  • Dispose of bulbs according to local regulations. Contains mercury.
  • Ensure the fixture is properly grounded.

Product Overview

The Philips MHC150/U/MP/3K Alto is a 150-watt metal halide bulb designed for various lighting applications requiring high intensity and warm white light. It features a clear ED17 bulb shape and a medium E26 base.

Philips 150W Metal Halide Bulb, angled view

Figure 1: Angled view of the Philips 150W Metal Halide Bulb, showing the clear glass envelope and internal arc tube assembly.

Philips 150W Metal Halide Bulb, side view

Figure 2: Side view of the bulb, highlighting the ED17 shape and the internal structure including the arc tube and support wires.

Philips 150W Metal Halide Bulb, front view

Figure 3: Front view of the bulb, showing the medium E26 screw base and the vertical alignment of the internal components.

Philips 150W Metal Halide Bulb, base view

Figure 4: Close-up view of the medium E26 screw base, showing the electrical contact points.

Setup and Installation

  1. Power Off: Ensure the power supply to the fixture is completely turned off at the circuit breaker before beginning installation.
  2. Fixture Compatibility: Verify that your lighting fixture is designed for 150W metal halide lamps and has an appropriate ballast. The fixture must also be enclosed to protect the bulb.
  3. Inspect Bulb: Carefully remove the new bulb from its packaging. Inspect the bulb for any signs of damage, such as cracks or scratches on the glass envelope. Do not install a damaged bulb.
  4. Install Bulb: Gently screw the bulb into the E26 medium base socket of the fixture. Do not overtighten. Ensure a snug fit to establish proper electrical contact.
  5. Secure Fixture: Close and secure the fixture's enclosure.
  6. Restore Power: Once the bulb is securely installed and the fixture is closed, restore power at the circuit breaker.

Note: Metal halide bulbs require a warm-up period to reach full brightness and color stability. This can take several minutes.

Operating Instructions

Once installed, the Philips MHC150/U/MP/3K bulb operates automatically when power is supplied to the fixture.

  • Initial Ignition: Upon turning on the power, the bulb will ignite and begin its warm-up cycle. The light output and color will stabilize over several minutes.
  • Re-ignition: If the bulb is turned off, it requires a cool-down period before it can be re-ignited. Attempting to re-ignite a hot bulb immediately may prevent it from striking or reduce its lifespan. Allow 5-15 minutes for the bulb to cool before attempting to turn it back on.
  • Operating Position: This bulb is designed for universal burn position, meaning it can operate in any orientation.

Maintenance

  • Cleaning: Ensure the power is off and the bulb is cool before cleaning. Gently wipe the outer glass envelope with a clean, dry, lint-free cloth. Do not use liquid cleaners or abrasive materials.
  • Replacement: Replace the bulb when it reaches the end of its rated life (approximately 16,000 hours) or if it exhibits signs of failure such as flickering, dimming, or failure to ignite.
  • Disposal: Metal halide bulbs contain small amounts of mercury. Dispose of spent bulbs according to local, state, and federal regulations. Many communities have recycling programs for mercury-containing lamps.

Troubleshooting

ProblemPossible CauseSolution
Bulb does not light up.No power to fixture.
Incorrectly installed bulb.
Faulty ballast.
Bulb has reached end of life.
Check circuit breaker and wall switch.
Ensure bulb is screwed in tightly.
Consult a qualified electrician to check ballast.
Replace bulb.
Bulb flickers or cycles on/off.Bulb nearing end of life.
Incorrect ballast.
Voltage fluctuations.
Replace bulb.
Ensure ballast matches bulb specifications.
Consult an electrician to check power supply.
Bulb takes too long to warm up.Normal operation for HID bulbs.
Aging bulb.
Allow sufficient warm-up time.
Consider replacing the bulb if warm-up time becomes excessively long.

Specifications

AttributeValue
BrandPhilips
Model Number046677134631
Part Number134635
Wattage150W
ANSI CodeM142/M102/O
Bulb ShapeED17
Base TypeMedium E26 Open Rated
Color Temperature3000 Kelvin (Warm White)
CRI (Color Rendering Index)85
ProtectedYes
Average Lifetime16,000 hours
Initial Lumens (light output)12,900
Burn PositionUniversal
Start MethodPulse Start
Voltage95 Volts
Item Weight3.2 ounces
MaterialCopper

Warranty and Support

For information regarding warranty coverage, technical support, or product inquiries, please contact Philips customer service or visit the official Philips website. Keep your purchase receipt as proof of purchase.

Philips Official Website: www.philips.com

© 2024 Philips. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.