1. Introduction
This manual provides essential information for the safe installation, operation, and maintenance of your REV Ritter Foot Switch, model 0509117555. Please read these instructions carefully before use and retain them for future reference.
2. Safety Instructions
- Electrical Safety: Installation and wiring must be performed by a qualified electrician or competent person in accordance with local electrical codes and regulations.
- Power Disconnection: Always disconnect power to the circuit before installing, wiring, or performing any maintenance on the foot switch.
- Intended Use: This foot switch is designed for use in dry indoor environments only. Do not expose it to moisture, water, or extreme temperatures.
- Cable Compatibility: Use only H03VVH2-F 2 x 0.75 mm² power cables for connection.
- Load Limits: Do not exceed the maximum rated current of 3 Amperes or operating voltage of 230 Volts. Overloading can cause damage or fire.
- Damage Inspection: Before each use, inspect the switch and cable for any signs of damage. Do not use if damaged.
3. Product Overview
The REV Ritter Foot Switch 0509117555 is an intermediate rocker switch designed for convenient control of electrical devices. It features a robust design suitable for various applications in dry environments.
Key Features:
- Intermediate rocker switch for two-wire connection cables.
- Equipped with a cable gland for secure cable entry.
- Rated for 230 V, max. 3 A.
- Designed for use with H03VVH2-F 2 x 0.75 mm² power cables.
- Features 4 screw terminals for reliable wiring.

Figure 1: Top-down view of the REV Ritter Foot Switch, showing the large rocker button for activation.

Figure 2: Front view of the foot switch, highlighting the textured surface of the rocker switch.
4. Setup and Installation
Follow these steps to correctly install the REV Ritter Foot Switch:
- Disconnect Power: Ensure the main power supply to the circuit is turned off at the breaker or fuse box before beginning any work.
- Open the Switch Casing: Carefully open the foot switch casing. This typically involves unscrewing the bottom plate.
- Prepare Cables: Strip the outer insulation of the H03VVH2-F 2 x 0.75 mm² power cable to expose the inner wires. Strip a small amount of insulation from the ends of the individual wires.
- Route Cables: Pass the power cable through the cable gland openings on the switch casing. Ensure the cable gland provides strain relief.
- Wire Connections: Connect the wires to the 4 screw terminals inside the switch. This switch is designed for a single-pole connection. Typically, one wire from the incoming power cable connects to one terminal, and the corresponding wire from the outgoing appliance cable connects to the adjacent terminal. The other two terminals are for the second wire of the two-wire cable, ensuring continuity. Refer to the internal wiring diagram if available inside the casing. Ensure all connections are tight and secure.
- Secure Cables: Tighten the cable gland to secure the cable and prevent it from being pulled out.
- Close Casing: Carefully close the switch casing, ensuring no wires are pinched. Secure the bottom plate with screws.
- Restore Power: Once installation is complete and verified, restore power to the circuit.

Figure 3: Side view of the foot switch, illustrating the cable entry point for wiring.

Figure 4: Bottom view of the foot switch, showing the screw holes for opening the casing and accessing the 4 screw terminals for wiring.
5. Operating Instructions
The REV Ritter Foot Switch operates with a simple on-off-on rocker mechanism:
- To turn on the connected device, press one side of the rocker switch with your foot.
- To turn off the connected device, press the opposite side of the rocker switch.
- The switch maintains its position (on or off) until pressed again.
6. Maintenance
The REV Ritter Foot Switch requires minimal maintenance:
- Cleaning: Clean the exterior of the switch with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the switch is disconnected from power before cleaning.
- Inspection: Periodically inspect the switch and its connected cables for any signs of wear, damage, or loose connections. Address any issues promptly.
- Environment: Ensure the switch remains in a dry environment to prevent electrical hazards.
7. Troubleshooting
If you encounter issues with your foot switch, consider the following:
- Device Not Turning On/Off:
- Check if the main power supply to the circuit is active.
- Verify that the connected appliance is functioning correctly when plugged directly into a power outlet.
- Ensure the cable connections inside the switch are secure and correctly wired. (WARNING: Disconnect power before opening the switch casing).
- Inspect the cable for any breaks or damage.
- Switch Feels Loose or Damaged: Discontinue use immediately and replace the switch. Do not attempt to repair internal electrical components.
If problems persist after troubleshooting, consult a qualified electrician.
8. Specifications
| Specification | Value |
|---|---|
| Brand | REV |
| Model Number | 0509117555 |
| Product Dimensions (LxWxH) | 8.3 x 7.2 x 2.6 cm |
| Item Weight | 70 g |
| Color | White |
| Power Type | Corded Electric |
| Wattage | 690 watts (at 230V, 3A) |
| Number of Items | 1 |
| Switch Type | 1-way |
| Included Components | Foot Switch |
| Operating Mode | On-off-on |
| Rated Current | 3 Amperes |
| Operating Voltage | 230 Volts |
| Contact Type | Normally Open |
| Terminal Type | Screw |
| Circuit Type | 1-way |
| Actuator Type | Foot Switch |
| Contact Material | Brass |
9. Warranty and Support
For warranty information and customer support, please refer to the documentation provided with your purchase or contact REV Ritter directly through their official website or authorized retailers. Specific warranty terms may vary by region and purchase date.