1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your GROHE 47010000 1/2" Thermo-Element. This component is designed for use in GROHE Grohmix thermostatic mixers to ensure precise and consistent water temperature control. Please read these instructions carefully before proceeding with installation or use to ensure optimal performance and longevity of the product.
2. Product Overview
The GROHE 47010000 is a replacement thermo-element, also known as a thermostatic cartridge, specifically engineered for GROHE Grohmix thermostatic shower and bath mixers. It utilizes bi-metal technology to react to changes in water temperature and adjust the hot and cold water mix, maintaining a stable output temperature. This ensures comfort and safety by preventing sudden temperature fluctuations.

Image 1: The GROHE 47010000 1/2" Thermo-Element, a key component for thermostatic water temperature control.

Image 2: A detailed view of the GROHE 47010000 Thermo-Element, showing its internal bi-metal coil and spring mechanism.
3. Specifications
| Feature | Detail |
|---|---|
| Model Number | 47010000 |
| Part Number | 47010000 |
| Set Name | 1/2" Thermostatic Cartridge |
| Material | Rubber (seals), Bi-Metal (thermo-element) |
| Nominal Inside Diameter | 0.5 Inches |
| Item Diameter | 0.5 Inches |
| Nominal Outside Diameter | 0.5 Inches |
| Temperature Range | Up to 73 Degrees Celsius |
| Item Weight | 12.6 ounces |
| Unit Count | 1.0 Count |
| Included Components | Installation Guide |
4. Installation
The GROHE 47010000 Thermo-Element is a precision component designed for specific GROHE Grohmix thermostatic mixers. Proper installation is crucial for its function and the safety of the user. An official installation guide is included with the product. It is highly recommended that installation be performed by a qualified plumber or technician to ensure correct fitting and calibration.
4.1 General Installation Steps (Consult Included Guide for Details):
- Turn off Water Supply: Before beginning any work, ensure the main water supply to the mixer is completely shut off.
- Drain System: Open the mixer to drain any residual water from the pipes.
- Access Cartridge: Carefully remove the handle and any retaining rings or covers to expose the existing thermostatic cartridge.
- Remove Old Cartridge: Unscrew or unclip the old thermo-element. Be prepared for some water leakage.
- Clean Housing: Clean the cartridge housing thoroughly to remove any scale or debris.
- Insert New Cartridge: Insert the new GROHE 47010000 thermo-element, ensuring it is correctly oriented and seated.
- Secure Cartridge: Re-secure the cartridge with its retaining components.
- Reassemble Mixer: Reattach the handle and covers.
- Restore Water Supply & Test: Slowly turn the water supply back on and check for leaks. Test the temperature control and adjust if necessary according to the included guide.

Image 3: A close-up view of the GROHE 47010000 Thermo-Element, highlighting its construction for precise fit.
4.2 Compatibility Information
It is essential to verify the compatibility of the GROHE 47010000 thermo-element with your specific Grohmix thermostatic mixer model. Refer to the compatibility chart provided below or consult your mixer's documentation. Using an incompatible part can lead to improper function or damage.

Image 4: Thermostatic Element Compatibility Chart. This diagram helps identify the correct thermo-element for various GROHE Grohmix models, including bath/shower, exposed, and concealed installations. The 47010 is listed under 'Grohmix' for various applications.
5. Operation
The GROHE 47010000 Thermo-Element operates automatically within your thermostatic mixer to maintain a constant water temperature. Once installed and calibrated, the mixer's temperature handle allows you to select your desired water temperature. The thermo-element continuously monitors the incoming hot and cold water temperatures and adjusts the mixing ratio to deliver water at the set temperature, even if there are fluctuations in the supply pressure or temperature.
This automatic regulation provides a comfortable and safe showering or bathing experience, preventing scalding from sudden hot water surges or discomfort from cold shocks.
6. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your thermostatic mixer and its thermo-element. While the thermo-element itself is a sealed unit, the surrounding components can benefit from periodic care.
- Cleaning: Clean the visible parts of your thermostatic mixer regularly with a soft cloth and a mild, non-abrasive cleaning agent. Avoid harsh chemicals, abrasive pads, or solvents, as these can damage the finish and seals.
- Limescale Prevention: In hard water areas, limescale buildup can affect the performance of the mixer. Periodically run the mixer at its hottest setting for a few minutes to help flush out any mineral deposits. If severe limescale is suspected, professional descaling may be required.
- Temperature Calibration Check: Occasionally check if the water temperature matches your desired setting. If significant discrepancies occur, recalibration might be needed (refer to your mixer's specific instructions or consult a professional).
- Professional Inspection: Consider having your plumbing system, including thermostatic mixers, inspected by a qualified professional every few years to identify and address potential issues before they become major problems.
7. Troubleshooting
If you experience issues with your thermostatic mixer, the thermo-element might be a contributing factor. Here are some common problems and potential solutions:
- Inconsistent Water Temperature: If the water temperature fluctuates significantly or does not remain constant, the thermo-element may be faulty or clogged with limescale.
- Water Not Hot Enough/Too Hot: If the mixer cannot achieve the desired hot or cold temperature, the thermo-element might be stuck or damaged. Ensure the hot and cold water supplies are correctly connected and at adequate pressure.
- Difficulty Adjusting Temperature: A stiff or difficult-to-turn temperature handle could indicate internal issues with the cartridge, possibly due to limescale.
- Reduced Flow Rate: While less common for the thermo-element itself, severe limescale buildup within the mixer, potentially affecting the cartridge, can reduce water flow.
Action: For any of these issues, first ensure that the hot and cold water supplies to the mixer are fully open and at sufficient pressure. If problems persist, the thermo-element may need cleaning, descaling, or replacement. It is recommended to consult a qualified plumber for diagnosis and repair.
8. Warranty Information
The GROHE 47010000 Thermo-Element comes with a LIMITED warranty. For specific details regarding the terms, conditions, and duration of your warranty, please refer to the warranty documentation included with your product or visit the official GROHE website. Keep your proof of purchase for warranty claims.
9. Customer Support
For further assistance, technical support, or to inquire about replacement parts, please contact GROHE customer service. You can typically find contact information on the official GROHE website or in the documentation provided with your product.
Online Resources: Visit the official GROHE website for product information, FAQs, and support resources.
Professional Assistance: For complex installation or repair issues, always consult a certified plumbing professional.