The Westinghouse Saf-T-Brace 0110000 is an all-metal support system designed for securely installing ceiling fans and lighting fixtures. This brace allows for installation from below the ceiling, eliminating the need for attic access. It provides a sturdy foundation for your fixtures, meeting safety standards for various weight capacities.

Safety Information

  • Always turn off power at the circuit breaker before beginning installation.
  • Ensure the brace is securely fastened to ceiling joists according to instructions.
  • This brace is UL listed for fixture support up to 150 lbs on 16-inch centers and 50 lbs on 24-inch centers. It is acceptable for fan support up to 70 lbs. Do not exceed these weight limits.
  • Consult a qualified electrician if you are unsure about wiring connections.
  • Wear appropriate safety gear, including eye protection, during installation.

Package Contents

Verify that all components are present before beginning installation:

  • Saf-T-Brace (Adjustable metal bar)
  • Dual-mount electrical box (15.5 cu. in.)
  • Saf-T-Cap (Protective cover)
  • Mounting hardware (screws, locknuts, bracket)
  • One Romex connector
  • Wire bushing
  • Instruction sheet
Image showing all components of the Westinghouse Saf-T-Brace kit, including the adjustable metal bar, electrical box, Saf-T-Cap, mounting bracket, screws, and Romex connector.
Figure 1: Included components of the Saf-T-Brace kit.

Setup and Installation

The Westinghouse Saf-T-Brace is designed for easy installation from below the ceiling. Follow these steps carefully:

Step 1: Prepare the Ceiling

Locate the desired installation spot. Cut a hole in the ceiling large enough to fit the electrical box, typically around 4 inches in diameter. Ensure the hole is positioned between two ceiling joists.

Diagram showing a hand inserting the Saf-T-Brace bar through a 4-inch hole in the ceiling, between two joists.
Figure 2: Inserting the Saf-T-Brace bar into the ceiling opening.

Step 2: Install the Brace Bar

Insert the Saf-T-Brace bar through the hole. Position it so that the ends rest against the ceiling joists. Rotate the bar until the teeth on both ends are fully embedded into the joists, securing the brace firmly in place. The square tube design allows for easy turning and adjustment.

Diagram showing a hand twisting the Saf-T-Brace bar to engage its teeth into the ceiling joists, securing it in place.
Figure 3: Twisting the bar to lock it into the joists.
Detailed view of the Saf-T-Brace bar showing the square tube for easy turning, threaded multiple lead for fast installation, and teeth that twist and lock into the joist. Also indicates 8-32 threads for cover plates and lightweight lighting fixtures, and 10-24 threads for ceiling fans and chandeliers on the electrical box.
Figure 4: Brace features and thread types.

Step 3: Attach Electrical Box and Fixture

Pull the electrical wires through the appropriate knockout in the electrical box. Secure the electrical box to the brace using the provided mounting hardware. The box features a strong magnet for hands-free installation. Once the box is secure, install your ceiling fan or lighting fixture according to its manufacturer's instructions. Use the 10-24 threads for heavier fans and fixtures, and 8-32 threads for cover plates or lightweight lighting fixtures.

Diagram showing the Saf-T-Brace with the electrical box attached, ready for a ceiling fan or lighting fixture installation.
Figure 5: Electrical box attached to the brace.
Close-up of the electrical box showing knockouts for Romex or conduit and a strong magnet for hands-free installation.
Figure 6: Electrical box details.
Image showing the Saf-T-Cap, Romex connector, ground screw, wood screws, locknuts, and mounting bracket.
Figure 7: Additional hardware components.

Installation Video Guide

This video provides a visual guide to installing the Westinghouse Saf-T-Brace for ceiling fans and lighting fixtures. It demonstrates the process of inserting the brace, securing it to joists, and attaching the electrical box.

Specifications

BrandWestinghouse
Model Number0110000
MaterialMetal
ColorSilver
Item Dimensions (L x W x H)4 x 15 x 3 inches
Item Weight1.9 Pounds
Electrical Box Capacity15.5 cubic inches
Fixture Support (16-inch centers)Up to 150 lbs
Fixture Support (24-inch centers)Up to 50 lbs
Fan SupportUp to 70 lbs
Mounting TypeCeiling Mount
UL ListedYes

Maintenance

The Westinghouse Saf-T-Brace is designed for long-term durability and requires minimal maintenance. Periodically inspect the installation for any signs of loosening or damage. Ensure all connections remain secure. No lubrication or specific cleaning is required for the brace itself.

Troubleshooting

If you encounter issues during or after installation, consider the following:

  • Brace not securing: Ensure the joists are within the 16-24 inch range and that the teeth are fully engaged by twisting the bar.
  • Fan wobble: A slight wobble can sometimes occur with ceiling fans. Ensure the brace is installed level and securely. Refer to your fan's instruction manual for balancing procedures.
  • Electrical issues: If the fan or light fixture does not operate, recheck all electrical connections. Ensure power is restored at the circuit breaker. If problems persist, consult a qualified electrician.

Warranty Information

Westinghouse offers an ultimate lifetime warranty for this product. If the Saf-T-Brace is found to be defective due to faulty materials or workmanship, Westinghouse will repair or replace the product for its lifetime.

Support

For further assistance or inquiries, please visit the official Westinghouse website or contact their customer support. Refer to the packaging or official website for the most current contact information.

Official Website: www.westinghouselighting.com

© 2026 Westinghouse. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.