Frequently Asked Questions 

1. What are the recommended operating temperatures for the UWB Module?

The UWB Module has an operating temperature range of -40°C to 95°C.

How should I handle FCC warnings related to the device?

Follow the FCC guidelines provided in the manual, including antenna reorientation, equipment separation, and seeking professional help if needed.

Product Overview/UWB Module

AMOSENSE-ASUWBM11-UWB-Module-FIG-5

HOW TO OPERATE

It is installed in the designated location of the vehicle and operates according to the designated CAN command.

PRODUCT INSTALLATION LOCATION

Bumper, Head lining, Trunk etc.

AMOSENSE-ASUWBM11-UWB-Module-FIG-1

SPECIFICATION

  • Standards
    UWB(Ultra Wide Band)
    • CCC Digital Key Phase3 Specification
    • IEEE 802.15.4-2015
    • IEEE 802.15.4z
  • UWB Ranging Distance Max. 10m(LOS/Line of Sight conditions, between Devices)
  • Power voltage 12V
  • Dimension(mm) 92.70 x 49.93 x 18.15

Dimension

AMOSENSE-ASUWBM11-UWB-Module-FIG-2

PIN MAP

AMOSENSE-ASUWBM11-UWB-Module-FIG-3

No.PIN NAME
1CAN_L
2CAN_H
3SUB_ID2
4SUB_ID1
5GND
6GND
7SUB_ID0
8B+_POWER

Electrical Characteristic

 MinTyp.MaxUNTI
Supply Voltage91216V
Operating Temperature-4095°C
Storage Temperature-4095°C

Product Specification

Name of companyAMOSENSE CO.,LTD.
Equipment / Model NameUNIT ASSY-ULTRA WIDEBAND / ASUWBM11
Identification CodeAmo
Year of manufactureSeparate mark
Manufacturer / CountryAMOSENSE CO.,LTD. / KOREA

AMO VINA CO.,LTD. / Vietnam

Operation FrequencyCH.5: 6.4896GHz

CH.9: 7.9872GHz

Max POWER(E.I.R.P)

(Mean Power Density)

CH.5: -42.39dBm/MHz

CH.9: -42.32dBm/MHz

Max Power(E.I.R.P) is EU measured power.

FCC

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device should be installed and operated with a minimum 20 cm between the radiator and your body.

IC Warning
This device contains a license-exempt transmitter(s)/receiver that complies with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:(1) This device may not cause interference.(2) This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment should be installed and operated with a minimum 20 cm between the radiator and your body.

Trade Name : HYUNDAI MOBIS Co., Ltd.

Trade Mark : AMOSENSE-ASUWBM11-UWB-Module-FIG-4