Qoltec 50900

QOLTEC 50900 Three Phase Electronic Energy Consumption Meter User Manual

1. መግቢያ

This manual provides detailed instructions for the installation, operation, and maintenance of the QOLTEC 50900 Three Phase Electronic Energy Consumption Meter. This device is designed for measuring active energy consumption in three-phase, four-wire AC circuits. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. የደህንነት መረጃ

ማስጠንቀቂያ፡- Installation and maintenance of this device must be performed by qualified personnel only. Failure to follow these instructions can result in electric shock, fire, or serious injury.

  • Always disconnect power before installing or servicing the meter.
  • Ensure all wiring connections are secure and correct according to the wiring diagram.
  • Do not operate the meter in environments exceeding its specified operating conditions.
  • Do not open or modify the meter casinሰ. በውስጥም ለተጠቃሚ አገልግሎት የሚሰጡ ክፍሎች የሉም።
  • Protect the meter from moisture, dust, and direct sunlight.

3. ምርት አብቅቷልview

The QOLTEC 50900 is a compact, DIN rail mountable electronic energy meter designed for accurate measurement of three-phase energy consumption. It features an LCD display for clear readings and a pulse output for remote monitoring.

QOLTEC 50900 Energy Meter with dimensions and key features

Figure 3.1: QOLTEC 50900 Energy Meter showing dimensions (75mm x 92mm x 76mm) and key features like Three Phase Type, 230V Rated Voltage, 1.0 Precision Class, and LCD Display.

ቁልፍ ባህሪዎች

  • Three-phase, four-wire measurement
  • LCD digital display for energy consumption (kWh)
  • DIN rail mounting (4P width)
  • High accuracy (Class 1.0)
  • Pulse output (400imp/kWh)
  • የአሠራር ጥራዝtage: 3x230/400V

4. ዝርዝሮች

መለኪያዋጋ
ሞዴል50900
ደረጃ የተሰጠው ጥራዝtage3x230/400V AC
ደረጃ የተሰጠው የአሁኑ3x10(100)A
ድግግሞሽ50Hz
ትክክለኛነት ክፍል1.0
ማሳያLCD
ጥራጥሬ ውጤት400imp/kWh
መጫንDIN Rail (4P)
ልኬቶች (W x H x D)75 x 92 x 76 ሚ.ሜ
ክብደት100 ግ
ቁሳቁስአክሬሊክስ

5. ማዋቀር እና መጫን

The QOLTEC 50900 meter is designed for standard 35mm DIN rail mounting. Ensure the installation location is dry, well-ventilated, and free from excessive vibration or electromagnetic interference.

5.1 መጫን

  1. Locate a suitable 35mm DIN rail within your electrical panel.
  2. Align the meter's DIN rail clip with the rail.
  3. Press the meter firmly onto the rail until it clicks into place.
QOLTEC 50900 Energy Meter mounted on a DIN rail

Figure 5.1: The QOLTEC 50900 meter securely mounted on a DIN rail, showing its compact form factor.

5.2 የወልና ግንኙነቶች

አስፈላጊ፡- All wiring must comply with local electrical codes and regulations. Ensure power is OFF before making any connections.

  1. Identify the input (IN) and output (OUT) terminals on the meter.
  2. Connect the incoming three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding IN terminals (typically 5, 6, 7, 8).
  3. Connect the outgoing three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding OUT terminals (typically 1, 2, 3, 4).
  4. ልቅ ግንኙነቶችን እና ከመጠን በላይ ሙቀትን ለመከላከል ሁሉም ግንኙነቶች ጥብቅ እና አስተማማኝ መሆናቸውን ያረጋግጡ።
Wiring diagram for QOLTEC 50900 Energy Meter showing input and output terminals

ምስል 5.2: ጎን view of the meter showing the wiring diagram for input (IN) and output (OUT) connections for L1, L2, L3, and Neutral.

Front and terminal views of QOLTEC 50900 Energy Meter

ምስል 5.3: የፊት view of the meter with its LCD display and a separate view of the terminal block for wiring connections.

6. የአሠራር መመሪያዎች

Once properly installed and powered, the QOLTEC 50900 meter will automatically begin measuring energy consumption.

6.1 ኤል.ሲ.ዲ ማሳያ

The LCD displays the total active energy consumption in kilowatt-hours (kWh). The display is continuous and does not require any button presses for basic reading.

Close-up of QOLTEC 50900 LCD display showing energy reading

ምስል 6.1: መቀራረብ view of the LCD display showing an example energy reading in kWh.

6.2 Pulse ውፅዓት

The meter features a pulse output (400imp/kWh) which can be used to connect to external monitoring systems for remote data collection. Refer to the external system's documentation for connection details.

7. ጥገና

The QOLTEC 50900 energy meter is designed for maintenance-free operation under normal conditions.

  • ማጽዳት፡ Use a soft, dry cloth to clean the meter's exterior. Do not use abrasive cleaners, solvents, or liquids that could enter the casing.
  • ምርመራ፡- Periodically inspect the wiring connections for any signs of loosening or damage. Ensure the meter is free from dust accumulation.
  • የአካባቢ ሁኔታዎች; Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the meter's lifespan.

8. መላ መፈለግ

If you encounter issues with your QOLTEC 50900 meter, refer to the following common problems and solutions:

ችግርሊሆን የሚችል ምክንያትመፍትሄ
ማሳያ/ቆጣሪ አልበራምNo power supply; Incorrect wiring; Blown fuse in circuitCheck power supply to the meter. Verify wiring connections. Check circuit breaker/fuse.
Incorrect energy readingIncorrect wiring; Faulty meterVerify wiring connections against the diagram. If wiring is correct, contact support.
Pulse output not workingIncorrect connection to external system; Faulty meterCheck pulse output wiring to the external system. Consult external system's manual. If issue persists, contact support.

If the problem persists after attempting these solutions, please contact Qoltec customer support.

9. ዋስትና እና ድጋፍ

Qoltec products are manufactured to high-quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Qoltec webጣቢያ. የግዢ ደረሰኝህን እንደ ግዢ ማረጋገጫ አቆይ።

© 2024 Qoltec. All rights reserved. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.