ALLIED-logo

ALLIED 97G2V Two Stage Variable Speed Gas Furnace

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-product

Product Information

Product Specifications

  • Product Name: 97G2V Two Stage Variable Speed Gas Furnace
  • Form No.: 97G2V-100 (02/2024)
  • Venting: To be used in conjunction with flue gas vent pipe
  • Heat Exchanger Design: For maximum durability

FAQ

  • Q: How do I determine the appropriate filter size for my furnace?
    • A: Refer to the Airflow Descriptor in the model number guide and select a filter with the minimum area specified for optimal performance.
  • Q: What should I do if I encounter issues with the motor or blower performance?
    • A: Contact customer support for troubleshooting and potential servicing options. Do not attempt to repair the unit yourself.

Information

CONFIGURATIONS

  • Upflow / Horizontal
  • Downflow

VENTING

  • 2-speed induced draft motor with stainless steel shaft, steel ball bearings, and fan cooled for long life
  • Vent materials for Canadian applications must comply with ULC S636
  • Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
  • Direct vent refers to a combustion air supply intake pipe installed in conjunction with flue gas vent pipe.

INSTALLATION FEATURES

  • Left or right gas and electric entry
  • Zero step horizontal conversion
  • Removable floor base (upflow/horizontal units) for bottom return air
  • All models comply with California’s South Coast Air Quality Management district Low NOx requirements

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-1

HEAT EXCHANGER DESIGN

  • Aluminized steel primary heat exchanger with crimped nonwelded construction
  • AL29-4C Stainless steel secondary heat exchanger
  • Non-welded crimped S-curve primary heat exchanger design for maximum durability

BURNERS

  • Aluminized steel in shot burners for smooth ignition
  • Isolated burner enclosure for quiet operation

CABINET CONSTRUCTION

  • Compact 33″ height
  • Standardized widths for easy coil fit
  • Unitized construction for cabinet integrity
  • Heat exchanger compartment is insulated to increase efficiency and reduce sound levels
  • Baked on pre painted steel cabinet finish

AIR DELIVERY SYSTEM

  • Efficient ECM variable speed blower motor
  • Motor features “soft start” and “soft stop” for quiet operation
  • Active and passive dehumidification feature
  • Easily removable slide-out blower design
  • Dynamically balanced blower wheel with resilient motor mounts for smooth and quiet operation

CONTROLS

  • Two stage gas valve
  • Integrated ignition and fan control
  • System Sentry™ control retains last five (5) fault codes with push button memory recall, regardless of power interruption
  • Hot surface ignition system uses silicon nitride ignitor
  • Control features 120 volt electronic air cleaner and humidifier terminals
  • Control circuit is fuse protected
  • Color coded control wiring
  • Compatible with single or two stage thermostats for heating.
  • Two stage thermostat is recommended when installed with two stage cooling unit.

WARRANTY

  • 10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.

California Only

  • If installed in South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
  • If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only: This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450.

MODEL NUMBER GUIDE

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-2

PHYSICAL AND ELECTRICAL DATA

  

 

MODEL

 

1ST STAGE

 

2ND STAGE

 

 

AFUE (ICUS)

 

NOM. COOLING CAPACITY (TONS)

 

GAS INLET (IN.)

 

VOLTS/

HZ/ PHASE

 

MIN. TIME DELAY BREAKER OR FUSE

 

 

NOMINAL F.L.A.

 

 

TRANS. (V.A.)

 

APPROX. WEIGHT (LBS.)

INPUT (BTUH)OUTPUT (BTUH)INPUT (BTUH)OUTPUT (BTUH)
UPFLOW/HORIZONTAL97G2UH045BV1229,00028,00044,00043,00097.031/2120-60-1157.740120
97G2UH070BV1243,00042,00066,00064,00097.031/2120-60-1157.740124
97G2UH090CV1257,00056,00088,00085,00097.031/2120-60-1157.740144
97G2UH090CV2057,00056,00088,00086,00097.051/2120-60-12012.840153
97G2UH110CV2072,00070,000110,000107,00097.041/2120-60-11512.840159
97G2UH135DV2086,00084,000132,000127,00097.051/2120-60-12012.840178
DOWNFLOW97G2DF070BV1643,00042,00066,00064,00097.041/2120-60-11510.140136
97G2DF090CV2057,00056,00088,00086,00097.051/2120-60-12012.840152
97G2DF110CV2072,00070,000110,000108,00097.051/2120-60-12012.840163

Note: For vent length and clearances to combustibles, please reference installation instructions.

FILTER REQUIREMENT DATA

 

Airflow Descriptor

Disposable FiltersCleanable Filters
Minimum Area (sq. in.)Minimum Area (sq.in.)
12576288
16768384
20960480
  1. The Airflow Descriptor is the two digits following the “B”, “C”, or “D” in the model number; e.g. “20” is the Airflow Descriptor.
  2. Areas shown for permanent filters are based on filters rated at 600 feet per minute face velocity.

BLOWER PERFORMANCE DATA

BLOWER PERFORMANCE DATA – UPFLOW / HORIZONTAL

  

 

MODEL

MOTOR SIZE (HP)BLOWER SIZE 

HEATING TEMP. RISE  (°F)

HEATING CFM @ .10″ – .80″ W.C. 

COOLING STAGE

COOLING CFM @ .10″ – .80″ W.C. 

 

SPEED ADJUST.

 

SETTING “D”

 

SETTING “C”

 

SETTING “B”

 

SETTING “A”

 

SETTING “D”

 

SETTING “C”

 

SETTING “B”

 

SETTING “A”

UPFLOW / HORIZONTAL 

 

 

 

97G2UH045BV12

 

 

 

 

1/2

 

 

 

 

10×9

 

35-65

High Fire

7458759901005 

2nd Stage

905107512101370+
68576589591081598011201255Norm
61069578581072088510201135
 

20-50

Low Fire

685765895910 

1st Stage

595760865980+
620705800820540660785890Norm
545625715725485600695790
 

 

 

 

97G2UH070BV12

 

 

 

 

1/2

 

 

 

 

10×9

 

50-80

High Fire

965106011301255 

2nd Stage

860106012151365+
880960990114081096011301265Norm
810840890103070584010051140
 

25-55

Low Fire

94099010701195 

1st Stage

600740840970+
8308959651100555665770855Norm
755825840975500600680790
 

 

 

 

97G2UH090CV12

 

 

 

 

1/2

 

 

 

 

10×9

60-90

High Fire

1060113512401315 

2nd Stage

875104012101360+
96010401120119980094511001245Norm
83093598010847208409701115
 

30-60

Low Fire

960104011201206 

1st Stage

625710830950+
8759459951100565670760860Norm
790840920950520610685785
 

 

 

 

97G2UH090CV20

 

 

 

 

1

 

 

 

 

11×11

40-70

High Fire

1450156517251865 

2nd Stage

1385159518202020+
13101450158516901225146516451885Norm
11551305145015451065132015041675
 

25-55

Low Fire

1120126514201520 

1st Stage

935105512751465+
96511201285139583598011201335Norm
8659501120123574087010101150
 

 

 

 

97G2UH110CV20

 

 

 

 

1

 

 

 

 

11×11

45-75

High Fire

1560176019051955 

2nd Stage

1310156017451955+
14151610174017951220140515701795Norm
12851485156016351075127014301635
 

35-65

Low Fire

1155132514201500 

1st Stage

935106512451405+
105512001310136086597011451280Norm
93510751170124579089010251165
 

 

 

 

97G2UH135DV20

 

 

 

 

1

 

 

 

 

11×11

 

55-85

High Fire

1650184520002055 

2nd Stage

1395164018402055+
14951660188019051290148016601905Norm
13601500167017051170133015001705
 

40-70

Low Fire

1300143516301652 

1st Stage

1015116013301480+
1190132514651491940108512001345Norm
109511901340134387096511101225

BLOWER PERFORMANCE DATA – DOWNFLOW

  

 

MODEL

MOTOR SIZE (HP)BLOWER SIZE 

HEATING TEMP. RISE  (°F)

HEATING CFM @ .10″ – .80″ W.C. 

COOLING STAGE

COOLING CFM @ .10″ – .80″ W.C. 

 

SPEED ADJUST.

 

SETTING “D”

 

SETTING “C”

 

SETTING “B”

 

SETTING “A”

 

SETTING “D”

 

SETTING “C”

 

SETTING “B”

 

SETTING “A”

DOWNFLOW 

 

 

 

97G2DF070BV16

 

 

 

 

3/4

 

 

 

 

11×10

 

35-65

High Fire

1110130514301700 

2nd Stage

1110134015751800+
995117513151520995123014201650Norm
880105511701365880108512901460
 

25-55

Low Fire

860102011401340 

1st Stage

74091510551255+
795910103012306608209401120Norm
6808259101085575735850995
 

 

 

 

97G2DF090CV20

 

 

 

 

1

 

 

 

 

11×11

40-70

High Fire

1395155516951825 

2nd Stage

1335160017501980+
12751395158516701225145016301830Norm
11451265140515251120127014501660
 

30-60

Low Fire

1130123013651475 

1st Stage

955111512651450+
1040113012501340855100511501285Norm
91010251130121075089010601170
 

 

 

 

97G2DF110CV20

 

 

 

 

1

 

 

 

 

11×11

45-75

High Fire

1595179519552010 

2nd Stage

1335158517902010+
14501615179518651220144016301865Norm
12901460161016801100127514751680
 

35-65

Low Fire

1165130514651547 

1st Stage

920109512651440+
105511851315140483096511301290Norm
93010701180127273586010351155

DIMENSIONS

DIMENSIONS (IN.) – UPFLOW / HORIZONTAL

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-3

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-4

 MODELABCD
 

UPFLOW/HORIZONTAL

97G2UH045BV1217-1/216-3/8167-5/8
97G2UH070BV1217-1/216-3/8167-5/8
97G2UH090CV122119-7/819-1/29-3/8
97G2UH090CV202119-7/819-1/29-3/8
97G2UH110CV202119-7/819-1/29-3/8
97G2UH135DV2024-1/223-3/82311-1/8

DIMENSIONS (IN.) – DOWNFLOW

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-5

ALLIED-97G2V-Two-Stage-Variable-Speed-Gas-Furnace-fig-6

 MODELABCD
 

DOWNFLOW

97G2DF070BV1617-1/216-3/81615-1/2
97G2DF090CV202119-7/819-1/219
97G2DF110CV202119-7/819-1/219

ACCESSORY LIST

CATALOG NUMBERDESCRIPTION
EXTERNAL FILTER RACK KITS
1.8410181 PACK (16 X 25)
1.84103910 PACK (16 X 25)
NATURAL TO LP KITS
11K482-STAGE – 90
11K47HIGH ALTITUDE 2-STAGE (>4500FT.)
RETURN AIR BASE
68W6217.5″   B WIDTH
68W6321.0″  C WIDTH
68W6424.5″  D WIDTH
DOWNFLOW COMBUSTIBLE FLOORING BASE
11M6017.5″   B WIDTH
11M6121.0″  C WIDTH
NIGHT SERVICE KITS
84W50TWO STAGE
HORIZONTAL SUSPENSION KIT
51W1080% & 90% KIT
FLUSH MOUNT TERMINATION (90% FURNACES ONLY) US ONLY
51W112″ & 3″ VENT VERSION
CONCENTRIC VENT KIT (90% FURNACES ONLY) US ONLY
71M801-1/2″ VENT VERSION
69M292″ VENT VERSION
60L463″ VENT VERSION
CONCENTRIC VENT KIT (90% FURNACES ONLY) CANADA
44W921-1/2″ AND 2″ VENT VERSION
44W933″ VENT VERSION

For vent length and clearances to combustibles, please reference installation instructions.

All specifications and illustrations subject to change without notice and without incurring obligations.

© 2024 Allied Air Enterprises LLC, a Lennox International Inc. Company

Documents / Resources

ALLIED 97G2V Two Stage Variable Speed Gas Furnace [pdf] Owner's Manual
97G2V Two Stage Variable Speed Gas Furnace, 97G2V, Two Stage Variable Speed Gas Furnace, Stage Variable Speed Gas Furnace, Variable Speed Gas Furnace, Speed Gas Furnace, Gas Furnace, Furnace

References

Leave a comment

Your email address will not be published. Required fields are marked *