1. Introduction
The ANENG M127 is a compact and intelligent digital multimeter designed for various electrical measurements. It features automatic function and range selection, ensuring ease of use for both professionals and DIY enthusiasts. With full-range overload protection and a clear 4000-count LED backlit screen, it provides reliable and accurate readings. This manual will guide you through the proper use and maintenance of your M127 multimeter.

2. Key Features
- Automatic Identification: Automatically selects the measuring function and range.
- High-definition Backlight: Clear LED backlit screen for visibility in various lighting conditions.
- 4000 Counts Display: Provides precise measurement readings.
- AC/DC Voltage Measurement: Capable of measuring both alternating and direct current voltages.
- NCV Voltage Sensing Mode: Non-contact voltage detection for safety.
- Live Wire Detection (Naught FireWire Recognition): Identifies live and neutral wires.
- Resistance Measurement: Measures electrical resistance.
- On-off Beep: Continuity test with audible indicator.
- Flashlight Lighting: Auxiliary lighting for dark environments.
- Data Retention: Holds the displayed measurement value.
- Low Power Prompt: Indicates when the battery is low.
- Automatic Shutdown: Powers off after 15 minutes of inactivity to save battery.
- Back Support Frame: Integrated kickstand for convenient hands-free operation.
- Full Range Overload Protection: Ensures durability and safety.

3. Setup
3.1. Package Contents
Before starting, please verify that all items are present in your package:
- ANENG M127 Digital Multimeter
- Test Leads (Pen line)
- User Manual
- Packaging Box

3.2. Battery Installation
The ANENG M127 multimeter requires 2 x 1.5V AAA batteries (not included). To install the batteries:
- Locate the battery compartment on the back of the multimeter.
- Open the battery compartment cover.
- Insert two AAA batteries, ensuring correct polarity (+ and -).
- Close the battery compartment cover securely.
4. Operation
4.1. General Use
The M127 features automatic selection of measuring function and range. Simply turn on the device and connect the test leads to the circuit or component you wish to measure. The multimeter will automatically detect the type of measurement (AC/DC voltage, resistance) and display the reading.
4.2. AC Voltage Detection
To measure AC voltage, insert the test leads into the appropriate input jacks (COM and INPUT). The multimeter will automatically detect AC voltage and display the reading. This function is designed for easy and fast measurement in maintenance tasks.

4.3. NCV (Non-Contact Voltage) Sensing
Press the 'NCV' button to activate the non-contact voltage sensing function. Bring the NCV sensor region (1 on the diagram) close to an AC voltage source. The screen's analog segment will increase, and a beep alarm will sound. The closer the distance to the voltage, the more urgent the alarm will be.

4.4. Live Wire Detection (Naught FireWire Recognition)
Press the 'NCV/Live' button (5 on the diagram) to switch to live wire detection mode. The 'Live' indicator light will illuminate and be accompanied by a beep when detecting a live wire. The zero line (neutral) will not trigger the indicator or beep.

4.5. Battery Detection
To test a battery, connect the test leads to the positive and negative terminals of the battery. The multimeter will display the voltage. When the red test lead (positive) touches the negative electrode, a '-' symbol will be displayed on the screen.
4.6. Other Functions
- Flashlight: Press the lighting button (3 on the diagram) to turn on the auxiliary flashlight for working in dimly lit areas.
- Back Brace: Utilize the back support frame (10 on the diagram) for fixed standing and hands-free operation.
- Component Detection: The multimeter can perform various component tests including on-off beep (continuity), DC voltage, resistance, and AC voltage measurements.

5. Specifications
| Function | Range | Resolution | Precision |
|---|---|---|---|
| AC Voltage | 1V~400V | 0.001V~1V | ±(0.8%+5) |
| DC Voltage | 0.6V~400V | 0.001V~1V | ±(0.8%+5) |
| Resistance | 0Ω~40MΩ | 0.1Ω~10kΩ | ±(2.5%+3) |
| NCV Voltage Induction | Yes | N/A | N/A |
| Live Naught Line | Yes | N/A | N/A |
| On-off Beep | Yes | N/A | N/A |
| Max Count | 4000 Counts | N/A | N/A |
| Operating Mode | Auto Range | N/A | N/A |
| Display Type | Digital Display | N/A | N/A |
| Operating Temperature | 0 - 40 ℃ | N/A | N/A |
| Power Supply | 2 x 1.5V AAA Battery | N/A | N/A |
| Automatic Shutdown | After 15 minutes without operation | N/A | N/A |
| Weight | 73g | N/A | N/A |
| Material | ABS | N/A | N/A |
| Certification | CE | N/A | N/A |
Note: The parameters are for reference only, and the actual measurement of the specific equipment shall prevail.
6. Maintenance
6.1. General Care
- Keep the multimeter clean and dry. Wipe the casing with a damp cloth; do not use abrasive cleaners or solvents.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Store the multimeter in a safe place, away from dust and moisture.
6.2. Battery Care
It is recommended to remove the batteries from the multimeter when it is not in use for an extended period. This prevents potential battery leakage and corrosion, which could damage the internal components of the instrument.
7. Troubleshooting & Safety Precautions
7.1. Safety Guidelines
- Electric Shock Hazard: Do not touch the test probes directly with your hands during testing to avoid electric shock.
- Inspect Test Leads: Before each use, inspect the test probes for any signs of damaged insulation or exposed metal. Do not use damaged leads.
- Correct Range Selection: Do not use the current and voltage ranges interchangeably, as this can damage the instrument.
- Unknown Values: If you are unsure of the magnitude of the voltage or current to be measured, always start with the highest available range and then adjust downwards to the appropriate range based on the measured value.
- Maximum Voltage: The maximum voltage between the measuring end and the ground is 400V DC or 400V AC. Do not exceed this limit.
8. User Tips
No specific user tips were available from reviews or Q&A for this product at this time. Always refer to the safety guidelines and operational instructions for best results.
9. Warranty and Support
For warranty information or technical support, please contact the ANENG Official Store or your point of purchase. Keep your purchase receipt as proof of purchase.