1. Introduction and Safety Information
Thank you for choosing the ANENG B15 Induction Teste Pen. This manual provides important instructions for the safe and effective use of your device. Please read it thoroughly before operation and keep it for future reference.
1.1. Unpacking Inspection
After opening the package, verify that the product is complete and undamaged. If any components are missing or damaged, please contact your retailer.
1.2. General Precautions
- Avoid Moisture: Do not use the product outdoors during rain or in high-humidity environments. Avoid contact with liquids to prevent electric shock.
- Do Not Disassemble: Unauthorized disassembly or repair by non-professionals is strictly prohibited. Improper operation may cause electric shock, fire, or product failure. Contact professional maintenance personnel if needed.
- Power Safety: Before use, ensure the power outlet is intact and undamaged.
- Prevent Dropping: Avoid dropping the product from elevated positions to prevent damage.
- Keep Children Away: Ensure children remain clear of the operational area during use. This product contains small parts that may cause choking hazards and is not suitable for children under 3 years unless under direct adult supervision.
- Intended Use: Do not use the product for any purpose other than its intended use. Misuse may cause injury, damage to the product, or other hazards.
- Protective Equipment: Always wear appropriate protective equipment when working with electrical systems.
2. Product Features
The ANENG B15 Induction Teste Pen is a versatile tool designed for various electrical testing scenarios.
2.1. Key Features
- Multi-functional Design: Suitable for various scenarios and capable of meeting diverse user needs.
- User-Friendly Operation: Intuitive interface design, suitable for users of all experience levels.
- Energy-Efficient Performance: Low-power operation helps conserve electrical energy.
- Enhanced Safety with NCV Technology: Features Non-Contact Voltage (NCV) technology for safe voltage detection.
- Accurate Fault Localization: Quickly and accurately identifies electrical faults and circuit breakpoints.
- Comprehensive Component Testing: Enables measurement of various electronic components with precision.
2.2. Component Overview

- Induction Indicator Light: Bright blue light, indicates induction.
- High Pressure Indicator: Bright red light, indicates high voltage.
- Flashlight Button: Press to turn on the LED flashlight.
- Touch Metal: The touch pole that needs to be contacted during measurement.
- Low Voltage/On-Off Indicator Light: Bright green light, indicates low voltage or power status.
- LED Flashlight: Assists with night work or in dimly lit areas.
- Chromium Vanadium Steel Batch: High hardness one-word screwdriver tip.
3. Setup
3.1. Battery Installation
The ANENG B15 Induction Teste Pen requires 2 x 1.5V AAA carbon dry batteries (not included). To install:
- Locate the battery compartment, usually at the top or back of the pen.
- Open the compartment cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
3.2. Initial Power On
Once batteries are installed, the device is ready for use. It typically activates an automatic detection mode upon power-on.
4. Operation
4.1. AC Voltage Detection (NCV)
The pen uses Non-Contact Voltage (NCV) technology to detect AC voltage without direct contact. As you approach a live AC voltage source, the pen will alert you with an increasing urgency of sound and the high pressure indicator (red light) will illuminate.
To test for AC voltage:
- Hold the pen and bring the tip close to the wire or outlet you wish to test.
- Observe the indicator lights and listen for the alarm. A green light typically indicates no voltage, while a red light and audible alarm indicate the presence of AC voltage.
4.2. Line Breakpoint Finding
The NCV mode can also be used to detect the signal strength of live wires, helping to pinpoint the exact location of circuit breakpoints.

To find a breakpoint:
- Move the pen along the insulated wire.
- The induction indicator light (blue) will be on where there is electricity.
- The point where the light turns off indicates a potential breakpoint in the line.
4.3. DC Detection
The pen supports DC detection. Connect the probe to the input, measure using the pen and probe tip, and switch on the power to activate the automatic detection mode.
4.4. Flashlight Function
Press the orange flashlight button (Component 3 in Figure 1) to turn on the LED flashlight. This assists with measurements in dark environments or during night work.
5. Cleaning and Maintenance
- Cleaning: Wipe off surface dust or stains promptly after use with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: When not in use, store the product in a dry, well-ventilated location, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries when the low voltage indicator light illuminates or if the device does not power on. Always use 1.5V AAA carbon dry batteries.
6. Specifications
| Attribute | Value |
|---|---|
| Brand Name | ANENG |
| Model | B15 |
| Certification | CE |
| Origin | Mainland China |
| DIY Supplies | Electrical |
| Display Type | Analog Only |
| Material | ABS/Chrome Vanadium Steel Batch |
| Voltage Range | 24-250V AC |
| Alarm Method | Sound and Light Alarm |
| Probe Type | One-word batch (screwdriver tip) |
| Batteries Used | 2 x 1.5V AAA Carbon Dry Batteries (not included) |
| Zero Live Line Inspection | Yes |
| Voltage Detection | Yes |
| Line Breakpoint Search | Yes |
| Electrical Switch Detection | Yes |
| Self-Check Function | Yes |
| DC Detection | Yes |
| Product Size | Approx. 160mm x 28mm x 27mm (6.3in x 1.1in x 1.06in) |

7. Troubleshooting
If you encounter issues with your ANENG B15 Induction Teste Pen, please consider the following:
- Device not powering on: Check if the batteries are correctly installed and have sufficient charge. Replace with new 1.5V AAA carbon dry batteries if necessary.
- Inaccurate readings or no detection: Ensure the pen tip is close enough to the object being tested. Verify that the environment is not excessively humid or wet, which can affect performance.
- Intermittent operation: Check for loose battery connections. Ensure the device is clean and free from debris.
For persistent issues, please refer to the warranty and support information.
8. Warranty and Support
For warranty claims, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format is available for download: View User Manual (PDF)