Introduction
This manual provides essential information for the safe and efficient operation of your Easun Hybrid Off-Grid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
Key Features
- Pure sine wave inverter output.
- Capable of running without a battery (PV input voltage higher than 200V).
- Built-in dual MPPT solar controller.
- Configurable input voltage range for various applications (home appliances, personal computers).
- Configurable battery charging current.
- Configurable AC/Solar Charger priority.
- Compatible with mains voltage or generator power.
- Automatic restart upon AC recovery.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Parallel capability for 11KW models (up to 6 units) for orders from end of August 2025.
Unboxing the Inverter
Carefully unpack the inverter and inspect for any damage. Ensure all components are present.
Video: Unboxing and initial inspection of the Easun Hybrid Solar Inverter, showing the main unit, user manual, and included accessories like connectors and a WiFi module.

Setup and Installation
Mounting the Unit
Consider the following points before selecting where to install the inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
CAUTION: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
PV Module Connection
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.

Battery Connection
The 11KP model supports a 48VDC system. Ensure correct polarity when connecting batteries.

Inverter Ports and Connections

Detailed port descriptions:
- PV1 input
- PV2 input
- AC input
- Grounding point
- Main output
- Second output
- Dry contact port
- RS232 communication port (DB9)
- RS485 communication port (RJ45)
- RS232 communication port (RJ45)
- Parallel communication port (only for parallel model)
- Battery negative/positive outlet hole
- Power on/off switch
Operating Instructions
Product Overview and Indicators

The front panel features:
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
LED Indicator Messages
| LED Indicator | Messages |
|---|---|
| AC / INV (Green Solid On) | Output is powered by utility in Line mode. |
| AC / INV (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
Function Key Descriptions
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
System Operation Diagrams

Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.
- Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and heat dissipation.
- Periodically check all wiring connections for tightness and signs of corrosion.
- Inspect the inverter for any visible damage or unusual noises.
- Ensure the operating environment remains within the specified temperature and humidity ranges.
Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact qualified service personnel.
- No Power Output: Check the power on/off switch, battery connections, and AC input. Verify that the utility grid or generator is supplying power if applicable.
- Fault Indicator On: Refer to the LED Indicator Messages table in the Operating Instructions section to identify the type of fault or warning. Address the underlying issue (e.g., overload, over temperature).
- Battery Not Charging: Check solar panel connections, PV input voltage, and AC input. Ensure the charging current settings are appropriate for your battery type.
- Unusual Noises: If you hear abnormal sounds, immediately disconnect power and inspect the unit for loose components or internal damage.
Specifications
The following table details the technical specifications for the Easun Hybrid Off-Grid Solar Inverter models.
| MODEL | ISolar-SMG-II-8.5KW-48V-WiFi | ISolar-SMG-II-11KP-48V-WiFi | ISolar-SMF-II-11KP-48V-WiFi |
|---|---|---|---|
| Capacity | 8.5KVA/8.5KW | 11KVA/11KW | 11KVA/11KW |
| Maximum PV Input Power | 10KW | 11KW | 11KW |
| Parallel Capability | NO | YES (6 pcs) | YES (6 pcs) |
| Lithium Battery Activation | YES (By PV or Utility) | NO | |
| Lithium Battery Communication | YES (RS485) | ||
| INPUT | |||
| Nominal Voltage | 230VAC | ||
| Acceptable Voltage Range | 170-280VAC (For personal Computer); 90-280VAC (For Home Appliances) | ||
| Frequency | 50/60Hz (Autosensing) | ||
| OUTPUT | |||
| Nominal Voltage | 220/230/240VAC | ||
| Surge Power | 17000VA | 22000VA | 22000VA |
| Frequency | 50/60Hz | ||
| Waveform | Pure Sinewave | ||
| Transfer Time | 10ms (For personal Computer); 20ms (For Home Appliances) | ||
| Peak Efficiency | 94% | ||
| Overload Protection | 5s@>=140%load; 10s@110%~140%load | ||
| Admissible Power Factor | 0.6~1 (inductive or capacitive) | ||
| BATTERY | |||
| Battery Voltage | 48VDC | 48VDC | 48VDC |
| Maximum Discharge Current | 180A | 220A | 220A |
| Floating Charge Voltage | 54VDC | 54VDC | 54VDC |
| Over Charge Protection | 63VDC | 63VDC | 60VDC |
| Charging Method | CC/CV | ||
| SOLAR CHARGER & AC CHARGER | |||
| Solar Charger TYPE | MPPT | MPPT | MPPT |
| Max. PV Array Power | 5000W*2 | 5500W*2 | 5500W*2 |
| Max. PV Array Open Circuit Voltage | 500VDC | 500VDC | 500VDC |
| PV Array MPPT Voltage Range | 60VDC~500VDC | 60VDC~500VDC | 120VDC~450VDC |
| Max. Solar Input Current | 18A*2 | 18A*2 | 18A*2 |
| Max. Solar Charge Current | 140A | 160A | 120A |
| Max. AC Charge Current | 120A | 120A | 120A |
| Max. Charge Current | 140A | 160A | 120A |
| PHYSICAL | |||
| Dimensions, DxWxH (mm) | 540*415*122 | 540*415*122 | 490*580*139 |
| Net Weight (Kgs) | 14 | 15 | 19.5 |
| Communication Interface | RS232/RS485/DRYCONTACT | ||
| LCD | YES | ||
| ENVIRONMENT | |||
| Operating Temperature Range | -10°C to 55°C | ||
| Storage temperature | -15°C to 60°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
User Tips
While no specific user tips were available from reviews or Q&A, here are some general recommendations for optimal performance:
- Regularly monitor the LCD display for status updates and any warning/fault indicators.
- Ensure your PV array voltage is consistently above 200V if operating without batteries.
- For parallel operation (11KW models from August 2025), ensure all units are properly configured and connected according to the parallel communication port instructions.
- Always consult the detailed user manual (if a PDF is available) for advanced settings and specific error codes.
Warranty and Support