1. Introduction
The Hantek 1008C/1008A is a cost-effective PC USB 8-channel automotive diagnostic oscilloscope, DAQ, and programmable signal generator. It features a 2.4MSa/s real-time sampling rate, 12-bit vertical resolution, and spectrum analysis function. Designed for vehicle testing, it includes an auto ignition probe and offers over 80 types of automatic diagnostic functions for various automotive systems. This manual provides essential information for setting up, operating, and maintaining your device.
2. Setup
2.1. System Requirements
The Hantek 1008C/1008A software supports the following operating systems:
- Windows NT
- Windows 2000
- Windows XP
- Windows VISTA
- Windows 7/8/10 (both 32-bit and 64-bit versions)
2.2. Hardware Connection
- Connect the Hantek 1008C/1008A device to your PC via the provided USB 2.0 interface cable. No external power supply is needed as the device is USB powered.
- Prepare a test lead. This typically involves a probe for the positive wire and a croc clip for the ground (GND) wire.
- Connect the test leads to the appropriate channels on the oscilloscope. The device features 8 analog channels (CH1-CH8).

2.3. Software Installation
Install the PC software from the provided CD or download it from the official Hantek website. The software is designed for easy installation without requiring additional drivers.
2.4. Visual Setup Guide
For a visual demonstration of connecting the device and preparing for a test, please refer to the video below. The video illustrates connecting the Hantek 1008C to a PC and attaching test leads to an engine component.
3. Operating Instructions
The Hantek 1008C/1008A offers a wide range of functions for automotive diagnostics and general oscilloscope use.
3.1. Software Interface
Once the device is connected and the software is launched, you will see a main interface allowing you to select different modules:
- Vehicle Diagnosis: For specific automotive tests.
- Oscilloscope: For general waveform analysis.
- Generator: To program and output various signals.

3.2. Vehicle Testing Functions
The Vehicle Diagnosis module provides over 80 types of automatic diagnostic functions, categorized as follows:
- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition.
- Ignition: Primary and secondary ignition tests.
- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position.
- Bus Diagnosis: CAN bus data examination, CAN bus signal integrity, CAN bus LH long-time acquisition, LIN bus.
- Performer: Tests for Petrol/Diesel systems.
- Starter and Charging Circuits: Diagnostics for starting and charging systems.

3.3. Oscilloscope Functions
The oscilloscope mode allows for detailed waveform analysis with the following capabilities:
- 8 analog channels.
- 2.4MSa/s real-time sampling rate.
- 12 bits vertical resolution.
- Spectrum analysis function.
- Input sensitivity from 10mV/div to 5V/div.
- Memory depth of 4K.
- Max input voltage of 400V (DC+AC Peak).
- Time base range from 1ns/div to 20000s/div.
- Trigger sources: CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8.
- Trigger mode: Edge.
- X-Y Mode: X-Axis Input CH1, Y-Axis Input CH2.
3.4. Programmable Generator
The 8-channel programmable generator can simulate various signals, such as crankshaft and camshaft signals, for testing and diagnostic purposes.
3.5. Measurement and Analysis
The device supports 20 types of automatic measurement methods, which can be called out or closed with one button for convenient and visual result readout. These include:
- Voltage Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot.
- Time Measurement: Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle.
- Cursor Measurement: Horizontal, Vertical, Track, Auto Measure Modes.
- Waveform Signal Process: Addition, subtraction, multiplication, division, FFT, Invert.


3.6. Saving Results
Diagnostic results can be generated as reports. You can print or take a screenshot to save the test results. The device also supports long-term recording of waveforms.
4. Maintenance
To ensure the longevity and optimal performance of your Hantek 1008C/1008A oscilloscope, follow these general maintenance guidelines:
- Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Store the device and its accessories in the provided carrying case when not in use to protect them from physical damage.
- Regularly check cables and connectors for any signs of wear or damage. Replace them if necessary.
- Ensure your PC's operating system and the Hantek software are up-to-date for the best performance and compatibility.
5. Troubleshooting
If you encounter any issues with your Hantek 1008C/1008A, consider the following basic troubleshooting steps:
- Device not recognized by PC: Ensure the USB cable is securely connected to both the device and the PC. Try a different USB port or cable. Verify that the software is correctly installed.
- No waveform display: Check all probe connections to the device and the test point. Ensure the correct channel is selected and enabled in the software. Adjust the time base and voltage range settings.
- Software issues: Restart the software and/or your PC. Ensure your operating system meets the minimum requirements and that the software is the correct version for your system (32-bit or 64-bit).
- Inaccurate readings: Perform a self-calibration if available in the software. Check probe attenuation settings (e.g., x1, x10) and ensure they match the physical probe settings.
For further assistance, refer to the technical support section within the software or contact Hantek customer support.
6. Specifications
| Category | Parameter | Value |
|---|---|---|
| Vertical | Analog Channel | 8 |
| Input Impedance | Resistance: 1MΩ | |
| Input Sensitivity | 10mV/div to 5V/div | |
| Input Coupling | DC | |
| Resolution | 12 bits | |
| Horizontal | Memory Depth | 4K |
| Max. Input | 400V (DC+AC Peak) | |
| Real-Time Sampling Rate | 2.4MSa/s | |
| Time Base Range | 1ns/div to 20000s/div (1-2-5 sequences) | |
| Time Base Precision | ±50ppm | |
| Trigger | Source | CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8 |
| Mode | Edge | |
| X-Y Mode | X-Axis Input | CH1 |
| Y-Axis Input | CH2 | |
| Cursors & Measurement | Voltage Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot |
| Time Measurement | Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle | |
| Cursors Measurement | Horizontal, Vertical, Track, Auto Measure Modes | |
| Waveform Signal Process | +, -, x, ÷, FFT, Invert | |
| Voltage Range | 10mV to 5V/div @ x 1 probe | |
| 100mV to 50V/div @ x 10 probe | ||
| 10V to 5000V/div @ x 1000 probe | ||
| 100V to 50000V/div @ x 10000 probe | ||
| 200mV to 100V/div @ 20:1 | ||
| Current Range | 100mA to 50.0A/div @ CC65(20A) | |
| 1000mA to 500.0A/div @ CC65(65A) | ||
| 1A to 100.0A/div @ CC650(60A) | ||
| 10A to 1000.0A/div @ CC650(650A) | ||
| 1A to 200.0A/div @ CC1100(100A) | ||
| 10A to 2000.0A/div @ CC1100(1100A) | ||
| FFT | Rectangular, Hanning, Hamming, Blackman Window | |
| Math | Addition, subtraction, multiplication, division | |
| Programmable Generator | Channel | 8 |
| Output Level | LVTTL | |
| Frequency Range | 0-250kHz | |
| Interface | USB 2.0 (Full Speed) | |
| Power | NO need extra power supply | |
| Physical | Size | 190 × 167 × 35 (mm) |
| Weight | 0.63kg | |
| Included Accessories | High Pressure Ignition Probe | 1 |

7. User Tips
- The Hantek 1008C/1008A is a USB Oscilloscope, meaning it requires a computer connection for operation and display.
- The device has a record length of 4K, which is useful for capturing and analyzing transient signals.
- Ensure your operating system is compatible with the Hantek software (Windows NT, 2000, XP, VISTA, 7/8/10, 32-bit and 64-bit versions are supported).
- The device supports multiple languages including English, German, and Chinese, which can be switched within the software interface.
8. Warranty and Support
For warranty information, technical support, or any product-related inquiries, please refer to the official Hantek website or contact your vendor. The software includes a direct link to technical support resources via a QR code.