iCallX KD200 Mobile Dispatch Console Instructions

iCallX KD200 Mobile Dispatch Console

iCallX KD200 Mobile Dispatch Console

Product Manual

Product Manual
Product Manual

Appearance

Appearance

Attachments

Please carefully open the package and check if it contains the items listed below. If any item is missing or damaged, contact your dealer promptly

No. Items QTY
1 Smart Terminal Host 1
2 Power Adapter 1
3 Hand Microphone 1
4 User Manual 1
5 Thermal Printing Paper 1

Basic Operations

Power On/Off Button

Operation Steps:

  1. Connect the power adapter to the DC input port.
  2. Press the power button until you hear a “click” sound, then release. If the button is stuck, the device is on; if it pops out, the device is off.
  3. Wait for 2 seconds until the backlight of the device turns on, then wait another 20 seconds for the system to boot up automatically

Precautions:
Please use the standard adapter provided with the product for connection.
When the battery is depleted to the point of shutting down, connect the power adapter for charging, then press the side switch. After it pops out, press it again to turn on the device.
If the device is in a state of excessive power consumption, charge it while the power button is pressed down.

Device Specifications

General Specifications
Network & Communication Standards RJ45 Network Port, WiFi 2.4GHz
Processor Dual-core Cortex-A72 and Quad-core Cortex-A53 Combination Architecture
Dimensions 430*165*222mm
Working Voltage DC 12~15V
Audio Specifications 5W*2
Working Temperature 0~50℃
Storage Temperature -20~60℃
Product Resolution 1920*1080P
Camera 2.0 M
Battery 4400mAh

FCC Statement

Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Information to user.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RF Exposure Information (MPE)
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
To ensure compliance with RF exposure guidelines, this equipment must be installed and operated with a minimum distance of 20 centimetres (8 inches) between the radiator/antennas and your body or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter unless authorized by the FCC.

IC Statement

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that can cause undesired operation of the device.

RF Exposure Information (MPE)
This equipment complies with ISED RF radiation exposure limits set forth for an uncontrolled environment.
To ensure compliance with RF exposure guidelines, this equipment must be installed and operated with a minimum distance of 20 centimeters (8 inches) between the radiator/antennas and your body or nearby persons.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter unless authorized by the ISED.

Logo

Documents / Resources

PDF thumbnailKD200 Mobile Dispatch Console
Instructions · KD200, Q5EKD200, dispatch console, mobile console, KD200 Mobile Dispatch Console, Mobile Dispatch Console, Dispatch Console, Console

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.