Frymaster Touchscreen Fryer Software Update

Key Specifications & Version Targets
| Component | Target Version / Value (from manual) |
|---|---|
| UIB/C/X | 10.00.146 |
| SIB | 04.01.000 or 04.02.000 or 04.02.001 |
| VIB | 01.03.003 |
| FIB | 10.00.063 |
| IOB (if applicable) | 10.77.004 |
| CAN end-of-line terminator resistors | 120 ohms (part number: 8075632) |
- Software update time: approximately 30 minutes (manual note)
- Power cycle/reset hold: 60 seconds (manual repeats)

READ THIS BEFORE SiARTlÅG!
IF REPLACING A CONTROLLER, DO NOT ATTACH THE NEW CONTROLLER YET!!!!!!!!!!!!!!!
- The software loaded on the enclosed USB drive MUST be loaded onto the fryer BEFORE attaching the new controller. This updates the existing boards and controllers on the fryer to recognize the new controller.
- Attaching the new controller before updating the software on the fryer may cause major complications due to incompatibility.
- If the controller being replaced is the far-left controller in the fryer, move an existing controller to the far-left position in the fryer. DO NOT ATTACH THE
- NEW CONTROLLER YET! Ensure the LED’s on the SIB board, in the open controller opening, are illuminated prior to updating software. If not, ensure the fuse is inserted and/or switches are on.
- Update the fryer software using the enclosed USB drive.
- Once the software is updated and verified on all existing controllers and boards, attach the new controller to the open controller position in the fryer battery.
Step 1 – Update the software
- On the left screen, press

- INSERT USB. The USB port is located inside the far-left cabinet, on the left-hand side. Slide or lift the cover to reveal the USB port.

- Follow the on-screen instructions.
- Press YES when the screen displays CONFIRM CONTROLLERS AVAILABLE FOR UPGRADE UIB, SIB, VIB AND FIB – YES/NO or SOFTWARE UPDATE WILL TAKE APPROXIMATELY 30 MINUTES. YOU WILL NOT BE ABLE TO COOK DURING THIS TIME. CONTINUE WITH SOFTWARE UPDATES?
- When the update has completed on ALL screens, press the YES button to confirm.
- If instructed to do so, remove the USB flash drive and lower the cover over the USB slot. If NOT instructed to do so, DO NOT remove the USB drive.
- Power cycle the system for 60 SECONDS. Failure to press and hold the reset switch long enough may cause an incomplete software update.
Step 2 – Verify the software update on all displays
- On ALL the screens, press

- When the versions are displayed, confirm they all match the versions below:
- UIB/C/X = 10.00.146
- SIB = 04.01.000 or 04.02.000 or 04.02.001
- VIB = 01.03.003
- FIB = 10.00.063
- IOB = 10.77.004 (if applicable)
- If software versions match on ALL screens, press
and proceed to Step 3 – Update the Menu. - If software versions DO NOT match, press
and repeat Step 1 – Update the Software.
Step 3 – Update the Menu
- On the left screen, press

- Insert the USB into the USB port.
- Select the file name of the menu (CSYS7) to update.NOTE: If the “INI FILE MISSING” message is displayed, USB SETTINGS OPERATION was selected instead of USB MENU OPERATION>COPY MENU FROM USB TO FRYER selection. Press the button,
press the
button, press the
button, and start over in step 1 of Step 3 – Update Menu. - Select the vats; the selected file in the previous step should update. Select EVERY vat if ALL vats are to be updated with the selected file (Example: If a 2-battery fryer should have all the vats updated to the same menu, select 1 & 2).

- Press the check
button to begin menu update. - When the update has completed on all screens, press the YES button to confirm.
- Ensure the USB is removed from the fryer.
- To power cycle the system, push and hold the black toggle switch for 60 SECONDS.
- Repeat steps 3 through 6 above to load additional menus.
- Once complete, slide the USB cover down to cover the port.
Troubleshooting
CAN COMMUNICATION FAILED: CAN communication error during an update or software freezes while updating
- Ensure the 8075632 end-of-line terminator resistors are installed in the SIB board in the far-left control box and on the FIB board. If they are missing or if the current resistors are bad, add or replace the resistors. The resistors should read 120 ohms.
- Try updating the software again, but ensure that only controllers with software that DOES NOT MATCH the software on the first page are located in the far-left position when updating software. Any controller that has software that matches the software version on the first page needs to be disconnected while updating the software and located in any position other than the far-left controller.
- Power cyclethe fryer, ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater.
- Update the software or menus again.
- Check software versions or menus. If they still do not update, repeat step #1 and recheck.
SOFTWARE UPGRADE IS grayed out

- Ensure ALL controllers are OFF.
- Ensure the software upgrade is performed on the far-left controller. VAT #2 will be grayed out, as software updates can NOT be performed on any controller other that VAT #1 controller.
- Go to SOFTWARE VERSION on all the controllers and ensure that BOARD IDs are correct. VAT 1=1, VAT2=2, etc.
- If the VAT ID is incorrect, follow the steps below to correct.
- a. On each screen, press

- b. Select the correct VAT ID for each vat. Vat ID #1 is the far-left controller. Vat ID #2 is the next controller to the right, etc.
- c. Once all VAT IDs are selected, power cycle the fryer for 60 seconds.

Software or menus do not update
- Try updating the software again, but ensure any controllers WITH matching software have power removed from them by removing the fuse on gas fryers or turning off the power switch under the component box on electric fryers. Ensure a controller with software that DOES NOT MATCH the software on the first page is in the far-left position when updating software.
- Recheck software versions. If they still do not update, repeat step #1 and recheck.
- Power cycle the fryer, ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater.
Menus only update to one fryer.
- Ensure that ALL vats are selected when updating menus.
Product Icons/Photos missing/Unknown Product

- Update the menu files again.
- Power cycle the fryer, ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater.
- Check menus. If they still do not update, repeat step #1 and recheck.
Display reboots automatically during an update
- Power cycle the fryer, ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater.
- Update the software or menus again.
- Check software versions or menus. If they still do notupdatet,e repeat step #1 and recheck.
Controller keeps rebooting after an update
- Ensure ALL controllers display OFF.
- Update the menu files again.
- Power cyclthe e fryer, ensuring that the reset switch is pressed and held for 60 seconds or greater, or power is removed for 60 seconds or greater.
- Check menus. If they still do not updat,e repeat step #1 and recheck.
Change Filter message after an FIB2 Reset
- This is normal after an FIB2 reset.
- Pull the filter pan slightly out of the cabinet until a “P” is visible in the top right corner of the display for 30 seconds or more, until the message disappears.
- Push the filter pan back into the fryer.