Qlima Mobile Split AC

IMPORTANT COMPONENTS
- Control Panel
- Indoor unit air supply unit
- Wheels
- Handle
- Outdoor unit air supply
- Indoor unit air inlet
- Connecting pipe
- Exhaust vent
- Power supply cord

WHAT’S INCLUDED

Dear Sir, Madam,
Congratulations on the purchase of this appliance. You have acquired a high quality appliance that will provide you with many years of pleasure, on condition that you use it responsibly. Reading these instructions for use before operating the appliance will optimise its life span. We wish you comfort with the new appliance.
Yours sincerely,
PVG Holding B.V.
Customer service department
SAFETY INSTRUCTIONS
Read this user manual carefully before using the appliance and keep it for future reference. Install this appliance only when it complies with local/national legislation, ordinances and stand-ards. This appliance is intended to be used as an air conditioner in residential houses and is only suitable for use in dry locations, in a caravan, in normal household conditions, indoors in living room, kitchen and garage.
IMPORTANT
- Never use the appliance with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges.
- The installation must be completely in accordance with local regulations, ordinances and standards.
- The appliance is suitable exclusively for use in dry places, indoors.
- Check the main voltage. This appliance is suitable exclusively for earthed sockets –connection voltage 220-240 Volt/ 50 Hz.
- The appliance MUST always have an earthed connection. You may absolutely not connect the appliance if the power supply is not earthed.
- The plug must always be easily accessible when the appliance is connected.
- Read these instructions carefully and follow the directions.
Before connecting the appliance, check that:
- The connection voltage corresponds to that on the type plate.
- The socket and power supply are suitable for the appliance.
- The plug on the cable fits the socket.
- The appliance is on a stable and flat surface.
- A distance of 50cm should be left between the appliance and other objects from front side and 20cm should be left between the appliance and other objects from left and right sides.
Have the electrical installation checked by a recognised expert if you are not sure that everything is in order.
- This appliance is a safe appliance, manufactured in accordance with CE safety standards. Nevertheless, as with every electrical appliance, exercise caution when using it.
- Never cover the air inlets and outlets.
- Empty the water reservoir through the water drain before moving it.
- Never allow the appliance to come into contact with chemicals.
- Do not insert objects into the openings of the appliance.
- Never allow the appliance to come into contact with water. Do not spray the appliance with water or submerge it as this may cause a short circuit.
- Always take the plug out of the socket before cleaning or replacing the device or a part of the device.
- NEVER connect the device with the aid of an extension cable. If a suitable, earthed socket is not available, have one fitted by a recognised electrician.
- Always consider the safety of children in the vicinity of this device, as with every electrical device.
- Always have any repairs – beyond regular maintenance – carried out by a recognised service engineer. Failure to do so may lead to invalidation of the guarantee.
- Always take the plug out of the socket when the appliance is not in use.
- If the power cable is damaged, it must be replaced by the manufacturer, its customer service department or persons with comparable qualifications in order to prevent danger.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
ATTENTION!
- Never seal the room – where this appliance will be used – completely airtight. This will prevent under pressure in this room. Under pressure can disrupt the safe operation of geysers, ventilation systems, ovens, etc.
- Failing to follow the instructions may lead to nullification of the guarantee on this device.
DECLARATION OF CONFORMITY
- PVG hereby declares that this appliance complies with the following EU directives:
- Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU
- Electromagnetic Compatibility (EMC) Directive 2014/30/EU
Ecodesign energy-related products Directive 2009/125/EC - Low Voltage Directive (LVD) 2014/35/EU
The full text of the EU declaration of conformity is available at the following internet address: https://www.qlima.com
| Parameter | Description |
| Working frequency | 2.412 to 2.472 GHz |
| Conducted power | 13 dBm to 23 dBm |
| Wi-Fi standard | IEEE 802.11b/g/n (channel 13) |
| Data transmission rate | 11b: 1, 2, 5.5, 11 (Mbps) 11g: 6, 9, 12, 18, 24, 36, 48, 54 (Mbps) 11n: HT20 MCS 0 to 7 |
| Antenna type | PCB antenna |
| Adaptive type | LBE under LBT based DAA |
| Antenna gain | 2.5 dBi |
Specific information regarding appliances with R32 refrigerant gas.
- Thoroughly read all of the warnings.
- When defrosting and cleaning the appliance, do not use any tools other than those recom-mended by the manufacturing company.
- The appliance must be placed in an area without any continuously sources of ignition (for example: open flames, gas or electrical appliances in operation).
- Do not puncture and do not burn.
- This appliance contains X g of R32 refrigerant gas.
- R32 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit. Be aware the refrigerants may not contain an odour.
- If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sourc-es of ignition.
- The appliance must be stored in such a way as to prevent mechanical failure.
- Individuals who operate or work on the refrigerant circuit must have the appropriate certi-fication issued by an accredited organization that ensures competence in handling refriger-ants according to a specific evaluation recognized by associations in the industry.
- Repairs must be performed based on the recommendation from the manufacturing com-pany.
Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrige- ants. Appliances shall be installed,operated and stored in a room with a floor area larger than 4 m2. The appliance shall be stored in a well-ventilated area where the room size corr sponds to the room area as specified for operation. 
INSTRUCTIONS FOR REPAIRING APPLIANCES CONTAINING R32
GENERAL INSTRUCTIONS
This instruction manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic, refrigerant and mechanical experience.
- Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system. - Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed. - General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Make sure that the conditions within the area have been made safe by control of flammable materials. - Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. nonsparking, adequately sealed or intrinsically safe. - Presence of fire extinguisher
lf any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. - No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed. - Ventilated area
Make sure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. - Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. lf in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: – the charge size is in accordance with the room size within which the refrigerant containing parts are installed;- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
- Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. lf a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. lf the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. lnitial safety checks shall include:- That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
- That there is continuity of earth bonding.
- REPAIRS TO SEALED COMPONENTS
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. lf it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that with working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that the appliance is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection
equipment. lntrinsically safe components do not have to be isolated prior to working on them. - REPAIR TO INTRINSICALLY SAFE COMPONENTS
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted tor the equipment in use.
lntrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test appliance shall be at the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. - CABLING
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continua! vibration from sources such as compressors or fans. - DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame} may not be used. - LEAK DETECTION METHODS
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum} is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipework.
lf a leak is suspected, all open flames shall be removed/extinguished.
lf a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves} in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. - REMOVAL AND EVACUATION
When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, it is important that good practice is followed since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing.The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the appliance safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system.
When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place. Ensure that the outlet tor the vacuum pump is not close to any ignition sources and there is ventilation available. - CHARGING PROCEDURES
In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines must be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken to not overfill the refrigeration system. Before recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the location. - DECOMMISSIONING
Before carrying out this procedure, it is essential that the technician is completely
familiar with the equipment and all its detail. lt is recommended that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. lt is essential that 4 GB electrical power is available before the task is commenced.- Become familiar with the equipment and its operation.
- lsolate system electrically.
- Before attempting the procedure, ensure that: mechanical handling equipment is available, if required, for handling refrigerant cylinders;
- All personal protective equipment is available and being used correctly; the recovery process is supervised at all times by a competent person;
- recovery equipment and cylinders conform to the appropriate standards.
- Pump down refrigerant system, if possible. lf a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. Make sure that cylinder is situated on the scales before recovery takes place.
- Start the recovery appliance and operate in accordance with manufacturer’s instructions.
- Do not overfill cylinders (No more than 80 % volume liquid charge).
- Do not exceed the maximum working pressure of the cylinder, even temporarily.
- When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site and all isolation valves on the equipment are closed off.) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
- LABELLING
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
- RECOVERY
- When removing refrigerant from a system, either for servicing or decommissioning, it is recommended that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
- The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery appliance, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
- The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery appliances and especially not in cylinders.
- lf compressors or compressor oils are to be removed, ensure that it has been evacuated to an acceptable level to make sure that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric healing to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
INSTALLATION OF THE APPLIANCE
- Open the packaging of the appliance and accessories. Check if the hoses between the indoor and outdoor units are properly connected. Also check if the water plug is securely plugged. Finally, check if the attachments are complete.
- Wrap the thermal protection sleeve on the hose between the outdoor and indoor unit (See image below).

- Stick the Velcro onto the window frames and onto the window. As shown in the picture:

- First, firmly stick the sealing cloth to the Window frames, then unzip the sealing cloth, and then stick the other side of the sealing cloth to the window. As shown in the picture:

- Fix the installation bracket component onto the window. The installation of the bracket component is relatively convenient, as shown in the diagram. Then, tighten the bolt by hand to firmly fix the bracket component on the window. As shown in the picture:

- When installing the outdoor unit, the buckle of the outdoor unit should be fastened to the ins- tallation bracket component, and the outdoor unit hook should be hung in the hook slot of the bracket rental. Finally, tighten the screw by hand. As shown in the image:

- Stick the base of the lock onto the window and its appropriate position (note: the two bases should not be too far apart to avoid insufficient length of the lock’s chain rope). As shown in the image:

- After the installation is completed. As shown in the following figure.
NOTE: The appliance shall be installed in a flat and empty place all around. Don’t block the air outlet, and the required distance around should be at least 50cm.
- If the outdoor unit requires the use of a drainage hose, simply install the drainage hose directly onto the water spout. Install as follows.
Note: When the appliance is in cooling or dehumidifying mode, the drain hose should be connec-ted to the cooling water spout at the bottom of outdoor unit ; When the appliance is in heating mode, the drain hose should be connected to the heating water spout at the bottom of outdoor unit.

OPERATION OF CONTROL PANEL
- Power
- Press this button to turn on/off the appliance
- Mode
- Press this button to select cooling, air supply, dehumidification, and heating modes.
- Temperature/time adjustment
- When in cooling/heating mode, pressing this key can adjust the set temperature up or down; In timed mode, press this key to adjust the timed on/off time.
- Fan speed
- Press this key to select high-end wind speed, mid-range wind speed. Low wind speed, silent wind speed, or strong wind speed.
- Timer
- Press this key in standby mode to set the timer Startup time; Press this key while in the power on state, Can set a timed shutdown time.
- Sleep mode (fan speed +timer key)
- Press this key combination in cooling/heating mode then enter sleep mode.
- Display Window
- This window displays the adjusted temperature and time.
- Swing (up+down)
- Press this key combination to turn on/off the swing function.
- WiFi function (optional)
- In standby mode, press the FAN button
on control panel for 3 seconds to enter WIFI network reset or unbind WIFI.
- In standby mode, press the FAN button
This appliance can be controlled with the remote control. Two AAA-batteries are required (these are not included).

FUNCTION INTRODUCTION
Cooling mode
- After powering on, the default cooling mode or pressing the mode button to select the cooling mode will turn on the cooling display light
. - Press the up or down button to adjust the temperature (between 16
). - Press the wind speed button to select high
wind speeds.
Air supply mode
- Press the mode button or select the air supply mode through the remote control, and the air supply indicator light
will turn on. - Press the wind speed button to select high
air speed. - Temperature cannot be set.
Dehumidification mode
- Press the mode button or select the Dehumidification mode through the remote control, and the Dehumidification light
will turn on. The four-way valve is closed in dehumidification mode. - Temperature control range: 16°C – 30°C.
- In this mode, there are functions such as timer, swing, and power-off memory.
- Press the air speed button to select low or silent air speed.
Heating mode
- Press the mode key or select the heating mode through the remote control, and the heating indicator light
will turn on. - Press the up or down button to adjust the set temperature between 16°C and 30°C..F
- Press the wind speed button to select high
speeds.
Sleep mode
- When turned on, press the sleep button on the remote control or the combination button on the control panel
to activate the sleep function. The display as which is only effective in cooling and heating modes. - The fan operates at a silent
wind speed. - After running for a while, the temperature to up (cooling mode) or down (heating mode).
- The appliance in sleep mode will automatically shut down after 8 hours.
MAINTENANCE
Declaration:
- Make sure the appliance is unplugged before maintenance.
- Do not use gasoline or other chemicals to clean this appliance;
- Do not wash the appliance directly;
- If the appliance is damaged, please contact the dealer or repair shop.
Cleaning
Caution: Unplug the power cord before cleaning the maintenance
- External cleaning
Wipe the outdoor unit with a damp cloth, and then thoroughly dry the equipment with a dry cloth. Do not allow water or harmful substances to enter this appliance. Do not use gasoline or other chemicals to clean the appliance; - Air filter
- It is important to regularly remove the dust from the filter.
- Remove the filter as shown in the picture below.
- Clean the filter with tap water and/or a vacuum cleaner to remove any dirty from the fil-ter.
- Do not use water hotter than 40° for cleaning and do not expose the filter to the sun.
- Make sure the filter has dried before putting it back in the appliance.

Maintenance
- Remove the rubber plug from the drainage outlet and drain the condensate water in the appropriate position.
- When the appliance is not in use for a long time, it is necessary to bring the outdoor unit back indoors to prevent dust, debris, etc. from falling into the air outlet.
Storage
- Remove the appliance from the installation location;
- Remove the rubber seal from the indoor unit and outdoor unit, drain the condensate water.
- Keep running in fan mode to make the internal dry.
- Turn off the appliance and pull down the plug.
- Wash the filter then install.
- Remove all the brackets on the appliance, install the brackets of the outdoor unit on the indoor unit, assemble as shown in the figure below.
- Store the appliance in a cool and dry place. We recommend to put the appliance back in the packaging when you store it. This prevents dirt and dust from collecting on the appli-ance.

The above technical parameters are subject to change without prior notice.
SMART LIFE WIFI CONNECTION GUIDE
Install App
Download the “Smart life” app from the Play Store (Android) or App Store (iOS).
Register
If you do not have a Smart life account, register or sign in with a verification code sent by SMS.
To register:
- Tap to enter registration page
- The system automatically recognizes your country/ area. You can also select the country code manually. Enter your mobile phone number/ email address and tap “Next”.
- If you choose the mobile phone number option, then enter the verification code in the message sent to you by SMS. Set a password as prompted and press “Confirm” to finish your registration

Connecting using Bluetooth
- Before initiating the connection, make sure the unit is in standby mode and the phone connected to the WiFi network..
- Press the “FAN” button
for 3 seconds to enter WiFi-connect mode and WiFi signal light
starts flashing. - Open the Bluetooth of your phone.
- When the appliance is powered on and to be connected, the connected Bluetooth appliance will pop up automatically after opening the App for a moment. Click “Add” button for connection.
- Enter the Wi-Fi information interface, enter the password and click “Next” to continue the operation. (note: network must be 2.4Ghz band)
- Enter the appliance connection interface after the progress bar is finished and the appliance is successfully connected.
- Click the “Done” button to enter the operation interface of the appliance.
ERROR CODE LIST
If the appliance does not work or works insufficiently:
Check if an error code is visible in the display, refer to the code table for a solution. If no error code is visible in the display, go through the error table for a possible solution.
| No | Cause | Code |
| 1 | Compressor drive IPM fault | F1 |
| 2 | PFC/IPM fault | F2 |
| 3 | Abnormal compressor start | F3 |
| 4 | Compressor operation error (press out of position) | F4 |
| 5 | Position detection circuit malfunction | F5 |
| 6 | Phase current overcurrent protection | FA |
| 7 | DC bus voltage overvoltage and under voltage protection | P2 |
| 8 | Indoor and outdoor communication failure | E4 |
| 9 | Main control board and driver board communication failure | F6 |
| 10 | AC input voltage protection | P3 |
| 11 | AC current overcurrent protection | P4 |
| 12 | AC overvoltage and under voltage protection | P5 |
| 13 | Outdoor outdoor panel sensor malfunction (reserved) | F7 |
| 14 | Return air sensor malfunction (reserved) | F8 |
| 15 | Exhaust sensor malfunction | E0 |
| 16 | Outdoor environment sensor malfunction (reserved) | E6 |
| 17 | Outdoor DC fan malfunction | E7 |
| 18 | Outdoor EE malfunction | FE |
| 19 | Abnormal temperature protection of return air sensor | PA |
| 20 | High temperature protection at the top of the compressor | P1 |
| 21 | Abnormal refrigerant circulation | PE |
| 22 | Exhaust temperature protection | PH |
| 23 | Outdoor coil overload protection (reserved) | PC |
| 24 | Feedback fault of indoor DC fan | E3 |
| 25 | Indoor coil overload protection | P6 |
| 26 | Indoor coil freezing protection | P7 |
| 27 | Indoor coil malfunction sensor malfunction | E2 |
| 28 | Indoor environmental temperature sensor malfunction | E1 |
| 29 | Indoor unit zero crossing detection fault | P8 |
| 30 | Indoor EE malfunction | EE |
| 31 | Feedback fault of water motor | E5 |
| 32 | Feedback fault of cooling fan | E8 |
| 33 | Full water protection | FL |
| 34 | Reversing fault of four-way valve | EA |
| 35 | System error | Eb |
WARRANTY CONDITIONS
This section of the manual outlines the terms and conditions of the guarantee for the appliance you have purchased. Scan the QR-code below that directs you to the full information and your rights regarding the product warranty. Please read the information specified on the weblink carefully. If there is no warranty support for your country, then please contact your local dealer.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. Do not throw batteries into the fire, where they can explode or release dangerous liquids. If you replace or destroy the remote control, remove the batteries and throw them away in accordance with the applicable regulations because they are harmful to the environment.
Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained personnel.
This equipment contains R290 refrigerant in the amount as stated in the table above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 3.
Documents / Resources