tuya E2-U Matter Over Thread Module Owner’s Manual

tuya-LOGOtuya E2-U Matter Over Thread Module

tuya-E2-U-Matter-Over-Thread-Module-PRODUCT

Overview

E2-U is a Matter over Thread module developed by Tuya Smart. It consists of a highly integrated radio frequency processor chip, E2, and a few peripheral components, with a built-in 802.15.4 PHY/MAC Thread protocol stack and various library functions.

E2-U comes with a low-power 32-bit ARM Cortex®-M33 CPU core, 4 MB of flash memory, 288 KB of SRAM, and configurable GPIOs that can function as digital peripherals for various applications. This module integrates all Thread MAC and TCP/IP libraries. All these resources can help develop your own Matter products.

Features

  • Built-in low-power 32-bit Cortex®-M33 CPU
  • Clock rate of 64 MHz
  • Wide operating voltage range: 1.8V to 3.6V (2.8V or above recommended)
  • Peripherals: 15 GPIO pins, two UART pins, one ADC pin, and five PWM pins
  • Thread connectivity
  • Support IEEE 802.15.4 MAC/PHY
  • Operating channels 11 to 26 @ 2.400 to 2.483 GHz, air interface rate of 250 Kbit/s
  • Maximum output power of +13 dBm
  • Onboard PCB antenna
  • Onboard PCB antenna with a gain of −1.04 dBi
  • Operating temperature range: −40°C to 105°C
  • Support hardware encryption, including AES 128/192/256, SHA224/SHA256, ECDH/ECDSA, ECJ-PAKE, and Curve25519
  • Bluetooth LE radio frequency (RF) features
  • Bluetooth LE
  • RF data rate of up to 2 Mbit/s
  • Transmitter power: +10 dBm
  • Receiver sensitivity: −96 dBm@Bluetooth LE 1 Mbit/s

Scope of applications

  • Smart building
  • Smart home and electrical appliance
  • Smart socket and light
  • Industrial wireless control
  • Baby monitor
  • Smart bus

Module interfaces

Dimensions and footprint
E2-U has three rows of pins with a 1.4±0.1 mm pin spacing.
The E2-U dimensions are 20.3±0.35 mm (L) × 15.8±0.35 mm (W) × 2.5±0.15 mm (H).
The figure below shows the dimensions of the E2-U module.tuya-E2-U-Matter-Over-Thread-Module- (1)

 Pinout

tuya-E2-U-Matter-Over-Thread-Module- (2) tuya-E2-U-Matter-Over-Thread-Module- (3) tuya-E2-U-Matter-Over-Thread-Module- (4) tuya-E2-U-Matter-Over-Thread-Module- (5) tuya-E2-U-Matter-Over-Thread-Module- (6)

P indicates the power pin, and I/O indicates the input and output pin.

Electrical Parameters

Absolute electrical parameters’

tuya-E2-U-Matter-Over-Thread-Module- (7)Normal operating conditions

tuya-E2-U-Matter-Over-Thread-Module- (8) tuya-E2-U-Matter-Over-Thread-Module- (9)

Power consumption during continuous transmission and reception

tuya-E2-U-Matter-Over-Thread-Module- (10)

The above reference data is based on non-signaling mode with a duty cycle of 99%.

Operating current

tuya-E2-U-Matter-Over-Thread-Module- (11)

The above data is based on the module being powered by a DC regulated power supply at 3.3V, utilizing the Tuya firmware keyhar5y73xvsgxe v1.0.8. For the same firmware, test results might vary slightly due to differences in the specific module and power supply used.

 RF parameters

Basic RF features

tuya-E2-U-Matter-Over-Thread-Module- (12)

 Transmitter (TX) performance

tuya-E2-U-Matter-Over-Thread-Module- (13)tuya-E2-U-Matter-Over-Thread-Module- (14)

 Receiver (RX) performance

RX sensitivity

tuya-E2-U-Matter-Over-Thread-Module- (15)

Power-on sequence of the module

tuya-E2-U-Matter-Over-Thread-Module- (16)

Antenna information

 Antenna type
Only PCB antenna applies.

 Antenna interference reduction
When a PCB antenna is used on an IEEE 802.15.4 module, we recommend that the module antenna is at least 15 mm away from other metal components. This can optimize the RF performance.
Make sure that the enclosure surrounding the antenna is not traced or filled with copper. Otherwise, the RF performance might be degraded.

 

tuya-E2-U-Matter-Over-Thread-Module- (17)

Packing and production instructions

Mechanical dimensions
The PCB dimensions are 20.3±0.35 mm (L) × 15.8±0.35 mm (W) × 1±0.1 mm (H).

tuya-E2-U-Matter-Over-Thread-Module- (18)

 Bottom view

tuya-E2-U-Matter-Over-Thread-Module- (19)

Pinout

tuya-E2-U-Matter-Over-Thread-Module- (20)

 Surface-mount technology (SMT) package

tuya-E2-U-Matter-Over-Thread-Module- (21)

The area indicated as keep-out in the diagram above does not require tinning and should not have any traces routed through it.

Production instructions

  • For the modules that can be packaged with the surface-mount technology (SMT) or in in-line form, you can select either of them according to the PCB design solutions of customers. If a PCB is designed to be SMT-packaged, package the module with the SMT. If a PCB is designed to use an in-line package, use wave soldering. Complete soldering within 24 hours after the module is unpacked. Otherwise, we recommend that you place the module in a drying cupboard with a relative humidity level below 10%, or pack the module in vacuum again. Then, record the packing time and duration of exposure. The total exposure time cannot exceed 168 hours.
  • Instruments or devices required for the SMT process:
  • Surface mount system
  • Solder paste inspection (SPI)
  • Reflow soldering machine
  • Thermal profiler
  • Automated optical inspection (AOI) device
  • Instruments or devices required for the wave soldering process:
  • Wave soldering device
  • Wave soldering fixture
  • Constant-temperature soldering iron
  • Tin bar, tin wire, and flux
  • Thermal profiler
  • Instruments or devices required for the baking process:
  • Cabinet oven
  • Electrostatic discharge (ESD) protection and heat-resistant trays
  • ESD protection and heat-resistant gloves
  • A delivered module must meet the following storage requirements:
  • The moisture-proof bag must be placed in an environment where the temperature is below 40°C and the relative humidity is lower than 90%.
  • The shelf life of a dry-packaged product is 12 months from the date when the product is packaged and sealed.
  • A humidity indication card (HIC) is put in the sealed package. tuya-E2-U-Matter-Over-Thread-Module- (22)
  • The module needs to be baked in the following cases:
  • The vacuum packaging bag is damaged before unpacking.
  • After unpacking, no HIC is found in the packaging bag.
  • After unpacking, the HIC indicates a humidity level of 10% or higher. In this case, the circle turns pink on the HIC.
  • The total exposure time has lasted for over 168 hours since unpacking.
  • More than 12 months have passed since the first sealing of the bag.
  • The baking parameter settings are described below:
  • Baking temperature: 40°C for reel packaging with relative humidity ≤ 5%. And 125°C for tray packaging with relative humidity ≤ 5% (use a heat-resistant tray, rather than a plastic container).
  • Baking time: 168 hours for reel packaging and 12 hours for tray packaging.
  • Temperature for triggering an alert: 50°C for reel packaging and 135°C for tray packaging.
  • Production can begin after a module has cooled down to below 36°C under natural conditions.
  • If a module remains unused for over 168 hours after being baked, it needs to be baked again.
  • If a batch of modules is not baked after exposure for more than 168 hours, do not use wave soldering to solder them. Because these modules are level-3 moisture-sensitive devices, they are very likely to get damp when exposed beyond the allowable time. In this case, if they are soldered at high temperatures, device failure or poor soldering performance might occur.
  • In the whole production process, take electrostatic discharge (ESD) protective measures.
  • To guarantee the pass rate, we recommend that you use the SPI and AOI to monitor the quality of solder paste printing and mounting.

Recommended oven temperature curve
Select a proper soldering technique according to the process. For more information, refer to the recommended oven temperature curve of either reflow soldering or wave soldering. The set temperatures might deviate from the actual temperature measurements. All temperatures shown in this module datasheet are obtained through actual measurements.
Technique 1: SMT process (recommended oven temperature curve of reflow soldering)
Set the oven temperatures according to the following curve.

  • A: temperature axis
  • B: time axis
  • C: alloy liquidus temperature from 217°C to 220°C
  • D: ramp-up slope from 1°C/s to 3°C/s
  • E: keep a constant temperature from 150°C to 200°C for a time period of 60s to 120s
  • F: temperature above liquidus temperature for 50s to 70s
  • G: peak temperature from 235°C to 245°C
  • H: ramp-down slope from 1°C/s to 4°C/s

tuya-E2-U-Matter-Over-Thread-Module- (23)

The curve above is based on solder paste SAC305. For more information about other solder pastes, see the recommended oven temperature curve in the specified solder paste specifications.

Technique 2: Wave soldering process (oven temperature curve of wave soldering)
Set the oven temperatures according to the following temperature curve of wave soldering. The peak temperature is 260°C±5°C.

tuya-E2-U-Matter-Over-Thread-Module- (24) tuya-E2-U-Matter-Over-Thread-Module- (25)

Storage conditions

tuya-E2-U-Matter-Over-Thread-Module- (26)

MOQ and packaging information

Product model MOQ (pcs) Shipping packaging Modules per reel Reels per carton
E2-U 4,400 Tape and reel 1,100 4

Appendix: Statement

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This device has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if not installed and used following the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the device and receiver.
  • Connect the device into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement

This device complies with FCC radiation exposure limits set forth for an uncontrolled rolled environment. This device should be installed and operated with a minimum distance of 20cm between the radiator and your body. Important Note
This radio module must not be installed to co-locate and operate simultaneously with other radios in the host system except following FCC multi-transmitter product procedures. Additional testing and device authorization may be required to operate simultaneously with other radios.

The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end-user. The host product manufacturer is responsible for compliance with any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed. The end-user manual shall include all required regulatory information/warnings as shown in this manual, including “This product must be installed and operated with a minimum distance of 20 cm between the radiator and user body”.

This device has got an FCC ID: 2ANDL-E2U. The end product must be labeled in a visible area with the following: “Contains Transmitter Module FCC ID: 2ANDL-E2U”. This device is intended only for OEM integrators under the following conditions:
The antenna must be installed such that 20cm is maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter or antenna. As long as the 2 conditions above are met, further transmitter tests will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.

Declaration of Conformity European Notice
Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU,2011/65/EU. A copy of the Declaration of conformity can be found at https://www.tuya.com.

tuya-E2-U-Matter-Over-Thread-Module- (27) This product must not be disposed of as normal household waste, in accordance with the EU directive for waste electrical and electronic equipment (WEEE-2012/19/EU). Instead, it should be disposed of by returning it to the point of sale, or to a municipal recycling collection point.
The device could be used with a separation distance of 20cm from the human body.

Documents / Resources

PDF thumbnailE2-U Matter Over Thread Module
Owner's Manual · 2ANDL-E2U, 2ANDLE2U, E2-U Matter Over Thread Module, E2-U, Matter Over Thread Module, Over Thread Module, Thread Module, Module

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.