Positioning Universal 25 Access Pad Owner’s Manual

OVERVIEW
The Access Pad-25 (AP-25) product is a finished IP67 enclosed keypad assembly. The IP67 key pad device is
designed to withstand the stresses of continuous operation in outdoor heavy equipment environment. The
device face will be the numerical keypad for manual entry of authorization code to use the equipment or
operator will also be able to tap their RFID card on the face to grant access to use the equipment or gain
access by having a secure BLE authorization tag or BLE smart phone. Additionally, User Interface will have
3 LEDs that will provide feedback based on the status of the Access Pad and whether access was granted or denied. The Equipment will be disabled via Keypad or a PUI telematics device controlling a set of relays.
The Access Pad will be powered by the equipment battery, and a backup battery will provide up to 30 days
of standby operation in case equipment battery is not available. The Access Pad will wakeup when a RFID
card, BLE TAG, BLE Phone or keypad is touched. The Access Pad-25 will be connected through the CANBus
(J1939) to the PUI Telematics Device for server communications. The access codes will be securely stored
on the keypad and updated from authorization servers as when access codes need to be updated. The
keypad will be able to operate together with or independent of the Telematics device to authorize access.
Three (3) different methods for mounting the Access Pad to equipment are supported by the design.
PLATFORM TECHNICAL REQUIREMENTS
Access Pad Block Diagram (To be updated with IO)
Feature Specifications
- Application MCU STM32C552CEU6 Microcontroller (512KB flash, 128KB RAM) to facilitate real- time CAN data filtering and monitoring will be utilized. :
- Ram/Flash sufficient to support Keypad application and list of access codes
- High-Speed CAN Interfaces with Standby Mode supporting either ISO-15765 CAN light duty
vehicles or J1939 heavy duty vehicles (CAN1 and CAN2). Preferably Microchip ATA6561- GAQW-N- Independent LDO power control and interrupt capability for each CAN so transceiver can remain on while device goes to sleep to support wake on CAN activity capability.
- Each CAN transceiver supports compliance with: ISO 15765 CAN (250 kbit/s or 500 kbit/s),SAE J1979, CAN FD, ISO 11898−5, ISO 11898-2, SAE J2284, SAE J1939 and CAN open
- Wake-up capability via CAN Bus and interrupt Application MCU
- J9139 support of ECM derived lifetime engine hours with adequate buffering
- CAN interface to PUI FJ2500, M7 and FJ2600 telematics devices.
- Real Time Clock (RTC) capability
- 4Mbyte Serial Flash is provided for non-volatile memory to:
- Store new firmware image during update and transition process
- Store encrypted authorization PINs for offline independent operation mode, no calls to server are required to authorize use.
- Storage of critical data (serial number, manufacturing data…etc) in non-volatile memory
- Support for RFID cards that use ISO14443A/B, ISO15693, MIFARE DESFire EV1, ISO/IEC 7186 and ISO/IEC 1443A cards
- Internal Serial UART port on PCB for pogo pin factory programming. Serial 3-wire UART AUX_TX/RX for console/programming console debug and firmware serial update port to support power through connector for fast powering in firmware updates using fixture or factory connection.
- JTAG connector for each MCU (Application, BLE, RFID).Use PUI JTAG connectors standard DF37NC, 10DS-0.4V(5.1) for each.
- MCU, BLE, RFID will support Over-The-Air (OTA) updates from PUI telematics device via CAN interface.
- RFID Reader 13.56 MHz (support for ISO14443A/B, ISO15693 and MIFARE DESFire EV1, ISO/IEC 7186 and ISO/IEC 1443A cards) such as TI TRF7970A.
- Integrated BLE V6.0 Bluetooth MCU /RF nRF54L05 (512KB flash, 96KB RAM) with support for
- Over-The-Air (OTA) updates supported from tethered PUI devices
- 1.3 uA ultra low Power mode w/RAM, RTC Radio operation
- AES256-bit Security, secure boot, Secure update, secure storage, tamper detectors
- Support for iBeacon and OEMDD protocols
- AoA/AoD plus Channel sounding for location direction and distance
- Internal Bluetooth antenna
- Interrupt based Sleep and Ship Management to be used to reduce current consumption during
times of sleeping and hibernating- Various power save/sleep modes (hibernate, normal sleep) selectable via software
- Power save mode sources for wake-up.
- Keypad button push
- RFID reader activity
- BLE activity
- CAN connectivity activity from Telematics device
- Scheduled with RTC
- Primary power state transition (add or remove primary power)
- Low battery threshold
- Power supply will be used in filtered 12/24/48/72 Volt automotive environments with brown out and shut down capabilities
- 7 – 90 Volt operating range – able to handle momentary dips below 6.5V in cranking conditions and alternator spikes per environmental specifications section.
- Resettable electronic fuse
- Internal ADC monitor for primary input power
- Over-voltage/current protection required
- Reverse polarity protection
- Independent power and reset control for all subsystems in the electrical design (LDOs). LDO control
from Application Management micro under firmware control to manage power save modes.
Application Management micro power up in active mode, while other subsystem power up off and have to be enabled - Power management states and current targets based on 12 volt Vin average
- Deep Sleep 50 uA @ 12V)
- BLE: ON
- RFID: ON
- Main MCU: Halted (CAN transceiver Interrupt)
- Wake-on: wake interrupt sources
- Active Input (<4mA @ 12V)
- BLE: ON
- RFID: ON
- MAIN MCU: ON
- Wake-on: N/A (already awake)
- Deep Sleep 50 uA @ 12V)
- Numerical Keypad (10 keys), a back and an OK key. Total of 12 keys in 4 rows.
- a membrane switch keypad with matrix output
- a graphical overlay (with LED cutouts)
- Durable in harsh environments
- UV resistance
- Chemical resistant
- Tactile feedback
- Three (3) color status LED (All lights Blink on system reset?)
- Ready LED – Green
- OFF – Sleep Mode/Not Ready
- Solid – Solid Ready Mode
- Blink – Upon key pressed on Keypad
- Access Status – Blue
- OFF – No Access request input from Keypad, RFID or BLE
- Slow Blinking – Validating operator for Access
- Solid – Access Granted (stays on for 10 seconds)
- Failure Status – Red
- OFF – No Access Issues
- Blink – X button hit
- Slow Blinking – Access request failure, code not accepted
- Fast Blinking – Access request failure, communications to server fail
- Solid – System Failure Maintenance Required
- Ready LED – Green
- 8 External connection Inputs and outputs listed below are present on PCB for harness connection.
- 2 general purpose analog relay control outputs – The design shall include (2) Open Collector type output which is capable of sinking up to 250mA. Output shall be capable of being connected to interface voltages ranging from -0.3V to 60V DC. This state is maintained over a power cycle (software config option)
- Ground
- Vin Equipment power (7-90V)
- 1 serial RS232 External interface (2-wires)
- CAN1 High/Low communications interfaces (2-wires).
- Internal Buzzer/Beeper to provide light beeping noise for feedback to keypad entry.
- Full Power reset capability by holding down the X key for long period (10 seconds)
- 1100mAh Recharge-able Internal back-up battery
- Internal ADC monitor for battery backup power voltage
- Batteries should support thermistor to monitor temperature in hardware in order to measure the temperature changes and detect extreme conditions of the battery pack. This is to detect temperature changes in order to shut down battery charge/discharge when extreme heat/cold conditions appear.
- Should allow product to operate if disconnected from main equipment power
- Shall provide enough capacity to check-in a minimum of once a day for 1 month plus provide for a single access during this period.
Platform Environmental Requirements
- Operating temperature range of -40 to +85 degrees C
- LI-Ion operating range when running on backup battery (-30 to +85 degrees C). Battery recharging
range is 0 to +80 degrees C based on internal battery temperature - Storage temperature range -45 to + 90 degrees C
- Humidity range of 0 to 95% non-condensing
- 12/24VDC vehicle environment Transients and Surges – ISO7637
- Random Vibration per SAE J1455 (Aug. 2012), Section 4.9, Figures 6, 7, & 8
- Mechanical Shock per SAE J1455 (Aug. 2012), Method 213B, Test Condition J
- Dust, Water and Ingress protection per IP67
- Water spray ingress protection per IP66
- ROHS2 and “Green” compliant
- ESD immunity J1455 at minimum +_8kV direct discharge and +- 12kV indirect discharge
- EMC/EMI J113EMC/EMI J1113
- Temperature Cycle per DIN EN 60068-2-14/IEC 60068-2-14
- Temperature Shock DIN EN 60068-2-14/IEC 60068-2-14,
- Damp Heat – Cyclic per D
- Mechanical Shock per
- DIN EN 60068-2-29/IEC 60068-2-29,
- DIN EN 60068-2-6/IEC 60068-2-6,
- DIN EN 60068-2-27
- UV Class (ASTM D4329/D5870)
Mechanical Features
The AP-25 is designed to have a heavy duty environmentally sealed case to, install on or under heavy duty construction equipment or on any outdoor equipment. The key features include:
- IP66 & IP67 sealed enclosure with mounting holes. Enclosure must withstand 5 years product life in extended weather, UV and diesel fuel protection environment.
- Size: Max Target dimensions: 55mm (w) x 10mm (h) x 85mm (l)
- Enclosure UV-stable black plastic with textured finish. The product enclosure shall be fabricated using PC/ABS black finish. Finish shall be a coarse grain texture intended to hide nicks and scratches from everyday exposure. The enclosure will be feature extra thick walls to provide a hardened and rugged use case for heavy duty industries. Enclosure needs to withstand extreme weather conditions, be rigid enough to withstand outdoor commercial uses and impacts. The enclosure should not deform or discolor when used in intended applications or during shipping.
- PCB to be held in place by snaps or 2mm screws (2.2 mm holes) within the enclosure during test, assembly and shipping.
- Enclosure should have molded in mounting flanges to support bolted or riveted installations. LEDs should be visible through IP67 sealed light pipes on the top of housing and easily visible during the install process.
- Gore vent to provide even pressure in sealed enclosure between inside and outside of sealed enclosure. Gore vent design needs to protect against high pressure sprayer without damage when vehicles/assets are cleaned
- A recessed area shall be provided on the back of the unit for attachment of the label on the exterior of the unit. This recess shall be minimal in depth, but sufficient to recess the surface of the label within the exterior surface plane of the enclosure. Contents of the label shall be explained further in Section 4.2
- 8 wire captured IP67 sealed harness, 20 AWG, to support Inputs and outputs listed below. Harness connector is M8. Molded harness rubber material must withstand 5 years product life in extended weather, UV and diesel fuel protection environment
- 8 wire harness with 30 cm length.
- The 8 wire M-8 harness leads are:
Pin Description Color Direction 1 Primary Power Red I 2 Ground Black GND 3 CAN High (J1939) Yellow I/O 4 CAN Low (J1939) Green I/O 5 RS232 – Rx White/Violet I 6 RS232 – Tx White/Grey O 7 Output 1 Light Green O 8 Output 2 Grey O • Mechanical Mounting: The AP-25 will need the ability to be mounted directly or via mounting brackets.
-
- Device will be secured using screws without the use of a bracket directly to the equipment via the mounting ears built in the plastic housing.
- An optional Bracket will be provided for AP-25 for an upright installs or flush with the fiber glass, control panel or metal of the equipment. A Plastic or Metal bracket that allows the keypad to be snapped securely in the bracket for added safety/protection. Bracket can be mounted on equipment via screws or strong industrial adhesive


CONCEPTUAL DESIGN

PRODUCT LABEL REQUIREMENTS
The product will require a single permanently attached product labels to print essential product and
regulatory information on, The label meet the following requirements:
- Standard white color
- Label information printed in black high contrast ink, easily readable
- The Static non-changing information to be printed on the label:
- FCC and IC regulatory certification information
- CE and eMark regulatory certification information
- “made in” or “assembled in” designation (Country of Origin)
- Any patent numbers
- Required variable or unit specifications information:
- Unique serial number for the unit
- Company logo or other customer logo as determined by model number
- Unique BLE MAC Address of the unit
- Unique RFID Address of the unit
- Manufacturing build date
The back label will be 79.5×39.5mm in size. The label should be waterproof and fade resistant under extended exposure to direct sunlight the bottom label shall contain the following information:
– Model Number
– FCC and IC identifiers
– CE Mark
– Serial Number/MAC Address in Numeric and Barcode form
The label shall be customizable for specific customers that desire their own identity information on the labels. In addition, customers may specify alternate information fields to be printed on the label.
PRODUCT ACCESSORIES
- 2 meter 6-Wire Fused power harness. The Red (+12V VCC primary power) should be fused using
sealed automotive fuse holder. The Black (Ground) does not need to be fused. fuses should be approximately 12 inches from end of harness. standard 3A ATC automotive fuse. - External starter relay Immobilization harness
- External alert/user feedback buzzer 85db to be heard within noisy construction environment
- Driver ID 1BLE Tags
- Driver ID RFID cards
- Mounting Bracket
PACKAGING REQUIREMENTS
Packaging
- The product will be enclosed in individually packaged boxes.
- When product is packaged in individual unit packaging, multiple units can be shipped in Master box of 20 (maybe 50?) units.
Package Labeling
- Master boxes shall be labeled on top and at least 2 opposing sides with model / part number in
both numeric and barcode forms. Labeling should also identify country of origin and container quantity - Individual Product Boxes shall be labeled with model / part number in both numeric and barcode forms
- Similar labeling mechanisms will be applied as currently deployed products
Packaging Standards
- Product and accessories must be able to survive, undamaged when fully loaded Bulk Shipping
Carton, Individual Product Box, or fully loaded Master Carton is subjected to standard flat drop and
corner drop tests at a height of 1 meter.
CERTIFICATION REQUIREMENTS
Regulatory Certifications
- FCC
- IC (industry of Canada)
- CE
- UKCA
- UKNI
- ROHS2 and “Green” compliant
- Prop65
Industry Certifications
- IP66 & IP67
- EMC…
Carrier Certifications
- Not Applicable
PRODUCT SCHEDULE
AP-25 KEYPAD PRODUCT SCHEDULE
AP-25 KEYPAD PRODUCT SCHEDULE
| WBS | Functional Area | Start | Finish | Week duration |
| 2 | Hardware Electrical Development Deliverables | 7-Apr | 1-Sep | 21 |
| 2.9 | P1 Engineering Samples Unit Available for firmware | 7/7 | 7/7 | 0 |
| 2.18 | P2 Engineering Samples Unit Available for firmware | 9/1 | 9/1 | 0 |
| 3 | Hardware Mechanical Development Deliverables | 7-Apr | 30-Aug | 21 |
| 3.4 | TO Mechanical Design Released for Tooling | 6/9 | 6/9 | 0 |
| 3.7 | TO Mechanical First Articles Review & Approved | 7/14 | 7/19 | 1 |
| 3.13 | T1 Mechanical First Articles Available | 8/18 | 8/23 | 1 |
| 4 | Firmware Development Deliverables | 19-May | 29-Aug | 15 |
| 5 | Software Development Deliverables | 7-Jul | 29-Aug | 8 |
| 6 | Certification Test Deliverables | 1-Sep | 10-Oct | 6 |
| 6.1 | FCC/IC Compliance Test & Report | 9/1 | 10/10 | 6 |
| 7 | Product Validation Test | 1-Sep | 27-Oct | 8 |
| 8 | Pilot Build & Validation | 29-Sep | 26-Dec | 13 |
| 8.6 | Pilot Build Run (100-500 units) | 11/3 | 11/15 | 2 |
| 8.9 | First Mass Production Build (500+ units) | 12/15 | 12/26 | 2 |
CE WARNING
The frequency band information supported by the device is as follows:
| Operating Mode | Operating Frequency Range(MHz) | The Maximum (EIRP)Transmitted Power (dBm) | |
| Tx | Rx | ||
| Bluetooth LE | 2402~2482 | 2402~2482 | 6.12 |
RF Exposure
This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance of 5mm between the radiator and
your body.
RED Declaration of Conformity
Hereby, Positioning Universal Inc, declares that this device is in compliance with the essential requirements
and other relevant provisions of Directive 2014 / 53 / EU. The full text of the EU declaration of conformity is available at the following internet address: Positioning Universal
FCC REGULATIONS
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference\ will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. - Consult the dealer or an experienced radio/ TV technician for help.
- Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. To
comply with FCC RF Exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for the transmitter must be installed to provide a separation distance of
at least 5mm from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter.
CANADA REGULATIONS:
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two
conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the
device
Cet appareil contient des émetteurs/récepteurs exempts de licence qui sont conformes aux CNR exempts de li cence d’Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deu
conditions suivantes :
- Cet appareil ne doit pas provoquer d’interférences.
- Cet appareil doit accepter toute inte interférence, y compris les interférences susceptibles d’entraîner un fonctio nnement indésirable de l’appareil
Caution:
This transmitter must not be co-located or operating in conjunction with any other antenna or transmit- ter.
This equipment should be installed and operated with a minimum distance of 5mm between the radiator and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou
émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 5mm entre le
radiateur et votre corps.

Documents / Resources
![]() | 25 Access Pad |
References
- positioninguniversal.com/www.positioninguniversal.com
- User Manualmanual.tools