rond stone socket 3.0 type E Installation Guide

rond-logo

rond stone socket 3.0 type E

rond-stone-socket-3-0-type-E-product

Specifications

  • Product Name: rond.io
  • Socket Type: Stone Socket 3.0 Type E
  • Available Cover Plates: Stone cover plate with continuous pattern, Stone cover plate without continuous pattern, Rond cover plate
  • Material Thickness Options: 16mm, 19mm, 22mm

Product Usage Instructions

Installation with Stone Cover Plate with Continuous Pattern:

  1. Waterjet the openings where the socket will be located using non-combustible, non-conductive materials.
  2. Use a 1mm waterjet to cut a cylinder with specific dimensions.
  3. Slice a 3mm cover plate from the cylinder with precise dimensions.
  4. Install the backfit holder on the junction box with the correct version based on material thickness.
  5. Fasten the backfit holder securely at the back of the material using appropriate glue or screws on a screw-fast surface.
  6. Attach wires to the socket, push the socket into the backfit holder, and install the stone cover plate using double-sided tape.
  7. Turn the power back on after installation.

stone socket 3.0 type E

Installation

Step 1

rond-stone-socket-3-0-type-E-fig- (1)

  1. For installation with stone cover plate with continuous pattern (gapping 1 mm) go to step 2 (click here)
  2. For installation with stone cover plate without continuous pattern (no gapping) go to step 5 (click here)
  3. For installation with rond cover plate (no gapping -different colors available) start with step 7 (click here)

Step 2: stone cover plate with continuous pattern

rond-stone-socket-3-0-type-E-fig- (2)

Waterjet the openings where the socket will be located.

Caution: only use non-combustible, non-conductive materials!

Step 3

rond-stone-socket-3-0-type-E-fig- (3)

Use a 1 mm waterjet to cut a cilinder with the above dimensions. Make sure to work precisely as the cilinder will be used to make the cover plate of the socket.

rond-stone-socket-3-0-type-E-fig- (4)

Slice a 3 mm cover plate from the cilinder. The finished cover plate should have the above dimensions. Continue to step 7 (click here)

Step 5 stone cover plate without continuous pattern

rond-stone-socket-3-0-type-E-fig- (5)

Drill/waterjet a hole where the socket had to be located.

Caution: only use non-combustible, non-conductive materials!

Step 6

rond-stone-socket-3-0-type-E-fig- (6)Make a stone cover plate following the dimensions above.

rond-stone-socket-3-0-type-E-fig- (7)

Product Code Name x
0042-0016 rond 3.0 backfit holder – 16 mm 15 – 17 mm
0042-0019 rond 3.0 backfit holder – 19 mm 18 – 20 mm
0042-0022 rond 3.0 backfit holder – 22 mm 21 – 23 mm

rond-stone-socket-3-0-type-E-fig- (8)

product code name x
0042-0016 rond 3.0 backfit holder – 16 mm 15 – 17 mm
0042-0019 rond 3.0 backfit holder – 19 mm 18 – 20 mm
0042-0022 rond 3.0 backfit holder – 22 mm 21 – 23 mm

If the finish material thickness is not 16, 19 or 22 mm (depending on choosen backfit holder), machine down or add (wooden) plate to achieve the correct total depth (16, 19 or 22 mm). rond-stone-socket-3-0-type-E-fig- (9)

For 2 or more.

rond-stone-socket-3-0-type-E-fig- (10)Install the backfit holder on the junction box.

rond-stone-socket-3-0-type-E-fig- (11)

Give it a twist.

rond-stone-socket-3-0-type-E-fig- (12) rond-stone-socket-3-0-type-E-fig- (13)

Fasten the backfit holder with junction box securely at the back of the material with the appropriate glue or screws on a scewfast surface.

rond-stone-socket-3-0-type-E-fig- (14) rond-stone-socket-3-0-type-E-fig- (15)

Pull the wires through.

rond-stone-socket-3-0-type-E-fig- (16)

Attach the wires to the socket.

rond-stone-socket-3-0-type-E-fig- (17)

Push the socket into the backfit holder.

rond-stone-socket-3-0-type-E-fig- (18)

Use double-sided tape to install the stone cover plate or click the plaster cover plate onto the socket.

rond-stone-socket-3-0-type-E-fig- (19)

  • Turn the power back on.

Gently remove the cover plate using a screwdriver. Place your finger between the screwdriver and the edge of the socket to prevent damaging the socket. Make sure the power is turned off before removal.

rond-stone-socket-3-0-type-E-fig- (20) rond-stone-socket-3-0-type-E-fig- (21)

Put the removal tool into the socket.

rond-stone-socket-3-0-type-E-fig- (22)

Pull out the socket.

rond-stone-socket-3-0-type-E-fig- (23)

Socket model scheme.

thank you for choosing rond

rond.io
Installation must be done by skilled professionals only and instructions must be followed at all times. Warranty will not apply in case of wrongful use or if unskilled personnel attempts to repair a product.

FAQs

Q: What should I do if the finish material thickness is not 16, 19, or 22mm?

A: If the thickness is different, machine down or add a wooden plate to achieve the correct total depth (16, 19, or 22mm).

Q: How do I remove the cover plate?

A: Power off the socket, gently remove the cover plate using a screwdriver by placing your finger between the screwdriver and the edge of the socket to prevent damage.

Q: What is the max center distance for multiple sockets?

A: For 2 or more sockets, the max center distance is 71mm.

Documents / Resources

PDF thumbnailstone socket 3.0 type E
Installation Guide · stone socket 3.0 type E, socket 3.0 type E, 3.0 type E, type E

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.