KyOCERa Fleet Services

Introduction
KFS can connect to devices in a variety of ways. This document will help you find the best connection method for customer requirements.
Revision history
| Version | Release Date | Revision |
| 1.00 | June 19, 2024 | First release |
Connection method
List of Connection Methods
The following outlines a list of device connection methods.
| Manageable Device | Number of connections | Communication | Protocol | Operation (Functionality) | |
| KFS Direct (With Manage mode) | – | Individually | Bi-directional | HTTPS XMPP/MQ TT | All operations available |
| KFS Direct (With Monitor mode) | – | Individually | Single-way communication, device to the server | HTTPS | Only monitor the device |
| NetGateway | Up to 2000 | Unified | Single-way communication, a device to the server | HTTPS | Monitor the device Support part of the operation |
| NetGateway-connected USB devices | Up to 2000 | Unified | Single-way communication, device to the server | HTTPS | Monitor the device Support part of the operation |

Recommended Connection Method
The recommended connection method for customer requirements is as follows:
| Customer requirements | Recommended connection method | Description | |
| Communication Path Requirements | |||
| No restriction. (Allow individual communication with devices.) | KFS Direct | The simplest connection method is to communicate directly with the device to KFS. | |
| Communication direction requirements | |||
| Restrict access from outside. | With Monitor mode | When Connection mode is set to Monitor mode, only device data collection is performed. – | |
| Perform remote maintenance. | With Manage mode | When Connection mode is set to Manage mode, remote maintenance can be performed in addition to device data collection. – | |
| Connecting competitor devices or legacy devices. | NetGateway | If a NetGateway has many managed devices, polling of device data may fail depending on the polling timing. For example, if a customer prints daily, the device information is updated daily, so those devices fall into the high-priority category. If a customer manages these devices and the device is only turned on during normal work hours (8 hours per day), the number of connections to a single NetGateway must be kept under 600 devices (polling interval: 6 hours). If customers print infrequently and their devices fall into the low-priority category, the number of connections to a single NetGateway must be kept under 200 devices (polling interval: 2*4=8 hours). If you set up to have multiple NetGateways to separate managed devices so that the polling interval is longer than the device turned ON interval it will be faster. | |
| Do not allow the device to connect to the network. | NetGateway-connected USB devices | Connect the USB cable between the NetGateway PC (Local Agent PC) and the device. | |
NetGateway connected USB Device Settings
- Add a device connected to the NetGateway PC (Local Agent PC) with a USB cable.
NetGateway Settings
- Install the local agent (KyoceraAgent.msi) on the PC that will be USB-connected to the device.

NetGateway – Add devices 
Troubleshooting flow:
- Wait a few minutes after completion of the Install Target device USB driver on the PC. Then, check after device discovery.
- Check if the device state is in a ready state.
- Check if device discovery settings are ok.
- Uninstall device USB drivers not used on the PC, and install only the target USB driver, if possible.
Check (Things to Check) details one by one:
| Location to check | Things to check | Discover USB devices |
| Server/PC where NetGateway is installed | Minimum hardware requirements are met | ✔ |
| ** | Supported OSs are met | ✔ |
| ** | Supported browsers are met | ✔ |
| ** | Supported .Net Framework is installed (other settings are default) | ✔ |
| ** | Default ports are available (9696/9797/8081) | ✔ |
| Server/PC where Local Agent is installed | Supported .Net Framework is installed | ✔ |
| ** | Local Agent is installed | ✔ |
| ** | KX Driver is installed (Test print works) | ✔ |
| NetGateway settings | Discovery settings – Discover USB-connected devices are enabled | ✔ |
| Device | Device is on | ✔ |
| ** | Device is awake (Device is not in sleep mode) | ✔ |
| Environment | Temporary disable some firewall or its rules, antivirus software, etc. | (if possible) |
Connection setting
Checklist Overview for Device Discovery/Registration/Online
| Settings/Configurations | All models Required | Specific Models Required | Note: Remote Panel case Required | |
| Device – Security Settings | ||||
| Certificate Verification | HASH: SHA2 Enabled | ✔ | – | – |
| Server-side Settings | TLS Version: TLS1.2 Enabled | – | ✔1 | – |
| HASH: SHA2 Enabled | – | ✔1 | – | |
| Client-side Settings | TLS Version: TLS1.2 Enabled | ✔ | – | ✔ |
| HASH: SHA2 Enabled | – | – | ✔ | |
| Device – Device Settings | ||||
| Date/Time | Within valid date/time range of certificate in KFS Server |
✔ |
– |
– |
| Device – Network Settings | ||||
| Proxy Settings | Compatible with the customer’s network environment | ✔ | – | – |
| Protocol | Enhanced WSD: or Enhanced WSD over SSL: -At least one, Enabled | ✔ | – | – |
| Not existed these settings but SSL is needed case, Secure Protocols: SSL Enabled | – | ✔2 | – | |
| HTTP/HTTPS: Enabled | ✔ | – | – | |
| Device – Management Settings | ||||
| Remote Services | Correct information e.g. Access Code, Server URL, etc. (Removed insufficient characters like “blank space”) | ✔ | – | – |
| Settings/Configurations | All models Required | Specific Models Required | Note: Remote Panel case Required | |
| SNMP | SNMPv1/v2c: Enabled | ✔ | – | – |
| Read Community: Compatible with NetGateway Discovery and Communication Settings | ✔ | – | – | |
| Write Community: Compatible with NetGateway Discovery and Communication Settings | ✔ | – | – | |
| When SNMP v3 is Enabled, then Compatible with NetGateway Discovery and Communication | ✔ | – | – | |
| Settings |
| Settings/Configurations | Required | |
| NetGateway – Discovery Settings | ||
| Communication Settings | SNMP Type: Compatible with Device Settings | ✔ |
| Secure protocol (SSL): Compatible with Device Settings | ✔ | |
| Device login: Compatible with Device Settings, valid User/PW info | ✔ | |
| PC – for Single Point Connection (SPC) Enabled case | ||
| Network environment | Confirm that Name resolution works fine in the network environment (Register devices with proxy settings “NetGateway installed computer name” as Hostname) Or, Set the actual IP address without hostname | ✔ |
| Firewall Inbound Rule: Permit specified Port (8081 as default – Possible to change it when NetGateway is first installed) | ✔ | |
- ✔1 is for the following models
- ✔2 is for legacy models that have Command Center, etc.
- ✔ is for all models
| Color Models | B&W Models |
| ECOSYS M5021cdn | ECOSYS M2135dn, ECOSYS M2635dn, ECOSYS M2635dw, ECOSYS M2040dn, ECOSYS M2540dn, ECOSYS M2540dw, ECOSYS M2640idw, ECOSYS M2735dw |
| ECOSYS M5520cdw, ECOSYS M5520cdn, | |
| ECOSYS M5521cdn, ECOSYS M5521cdw, | ECOSYS M2235dn, ECOSYS M2735dn, |
| ECOSYS M5525cdn, ECOSYS M5526cdn, | ECOSYS M2835dw |
| ECOSYS M5526cdw | |
| ECOSYS M6030cdn, ECOSYS M6530cdn | ECOSYS M3040dn, ECOSYS M3540dn |
| ECOSYS M6035cidn, ECOSYS M6535cidn | ECOSYS M3040idn, ECOSYS M3540idn, ECOSYS M3550idn, ECOSYS M3560idn |
| ECOSYS M6230cidn, ECOSYS M6630cidn, ECOSYS M6235cidn, ECOSYS M6635cidn |
ECOSYS M3145idn, ECOSYS M3645idn |
| ECOSYS M8130cidn, ECOSYS M8124cidn | ECOSYS M3660idn, ECOSYS M3655idn, ECOSYS M3145dn, ECOSYS M3645dn |
| ECOSYS P5020cdw, ECOSYS P5020cdn, ECOSYS P5021cdn, ECOSYS P5021cdw, |
ECOSYS M4132idn, ECOSYS M4125idn |
| ECOSYS P5025cdn, ECOSYS P5026cdn, ECOSYS P5026cdw |
| ECOSYS P6130cdn, ECOSYS P6035cdn, ECOSYS P7040cdn | ECOSYS P2235dn, ECOSYS P2235dw, ECOSYS P2040dn, ECOSYS P2040dw, ECOSYS P2235d, ECOSYS P2230dn |
| ECOSYS P6230cdn, ECOSYS P6235cdn, ECOSYS P7240cdn | ECOSYS P2335d, ECOSYS P2335dn, ECOSYS P2335dw |
| ECOSYS P8060cdn | ECOSYS P3060dn, ECOSYS P3055dn, ECOSYS P3050dn, ECOSYS P3045dn |
| ECOCYS MA2100cwfx, ECOCYS MA2100cfx, ECOSYS MA2100cx | ECOSYS P4060dn |
| Color Models | B&W Models |
| ECOCYS PA2100cwx, ECOCYS PA2100cx | TASKalfa 3511i, TASKalfa 3011i |
| TASKalfa 3060ci | TASKalfa 4012i, TASKalfa 3212i |
| TASKalfa 306ci, TASKalfa 356ci, TASKalfa 406ci |
TASKalfa 4020i |
| TASKalfa 307ci | TASKalfa 6002i, TASKalfa 5002i, TASKalfa 4002i |
| TASKalfa 6052ci, TASKalfa 5052ci, TASKalfa 4052ci, TASKalfa 3552ci, TASKalfa 3252ci, TASKalfa 2552ci | TASKalfa 8002i, TASKalfa 7002i |
| TASKalfa 8052ci, TASKalfa 7052ci | TASKalfa 9002i |
Examples with Screenshots
Device – Security Settings
- Certificate Verification
- HASH: SHA2 Enabled

Server-side Settings
- TLS Version: TLS1.2 Enabled
- HASH: SHA2 Enabled

Client-side Settings
- TLS Version: TLS1.2 Enabled
- HASH: SHA2 Enabled

Device – Device Settings Date/Time
- Within valid date/time range of certificate in KFS Server

Device – Network Settings Protocol
- Enhanced WSD and Enhanced WSD over SSL should be enabled.

Device Management Settings
Remote Services
- Correct information e.g. Access Code, Server URL etc.
- (Insufficient characters like a “blank-space” were removed)

SNMP
SNMPv1/v2c: Enabled
- Read Community: Compatible with NetGateway Discovery and Communication Settings.
- Write Community: Compatible with NetGateway Discovery and Communication Settings.
- When SNMP v3: Enabled Compatible with NetGateway Discovery and Communication Settings.

NetGateway – Discovery Settings Communication Settings
- SNMP Type: Compatible with Device Settings.
- Secure protocol (SSL): Compatible with Device Settings.
- Device login: Compatible with Device Settings, valid User/PW info.


PC computer – for Single Point Connection (SPC) Enabled case.

Network environment
- Confirm that Name resolution works fine in network environment.
- (Register devices with proxy settings “NetGateway installed computer name” as Hostname) or Set actual IP address without hostname.

- Firewall Inbound Rule: Permit specified Port (8081 as default – Possible to change it when NetGateway is first installed).

Notes for success of Device Discovery/Registration/Online
- Check whether or not the previous registered device still shows in KFS Manager:
- When Remote Services settings is turned OFF, via U520 or CCRX without deleting the device in KFS Manager, then the previous registered device remains in KFS Manager.
- You must search KFS Manager with both “Serial number” and “MAC address” on the device and delete the previous remaining device in KFS Manager. If not deleted, then device registration will fail with error code 403.
- When you have Unstable SNMP responses, a good way to prevent this issue is to make the NetGateway Timeout setting longer
- Confirm that no problems are found in network environment
Additional information on NetGateway
Device information polling
- NetGateway periodically polls Alert data, Counter data and Consumable data from each device. This is because NetGateway to Device communication is uni-directional which means there is no Device to NetGateway communication.
- The polling interval for each device can be changed depending on the number of managed devices (displayed devices) on the NetGateway device list.
- The more devices you have on KFS, the longer the interval will be between polling. If your NetGateway has a lot of devices, the polling interval can be longer.
- Also, if the device data (toner level or counter value) is not frequently updated, the priority category will be lower. As a result, the polling interval will be longer and your device will be put into the category depending on the devices registered.
| Alert | Counter/Consumables | ||||||||||
| Number of Devices | 2,000~
1,001 |
1,000~
301 |
300~
101 |
100~
26 |
25~1 | 2,000~
1,001 |
1,000~
601 |
600~
201 |
200~
101 |
100~26 | 25~1 |
| High Priority Category | 120
(min) |
60
(min) |
15
(min) |
5
(min) |
1
(min) |
24 (hrs.) | 12 (hrs.) | 6 (hrs.) | 2 (hrs.) | 60 (min) | 60 (min) |
| Middle Priority Category | x2 | 1
(min) |
x2
(Note) Polling must be executed once a day. |
||||||||
| Low Priority Category | x4 | 1
(min) |
x4
(Note) Polling must be executed once a day. |
||||||||
If the target device is turning ON only for a specific period, normal work hours and the polling interval by NetGateway is longer for the device, the device information polling can fail. In this case, you can solve the problem in two ways:
- Having multiple NetGateways to separate managed devices.
- Turning on the device for longer hours.
Authentication type/Authentication information
- Authentication type/Authentication information is used for Enhanced WSD communication with the device.
- Enhanced WSD communication is TCP-based communication and can have more stable communication with the device, unlike SNMP (UDP-based communication).
- To use Enhanced WSD communication, you need to enable Enhanced WSD and/or Enhanced WSD over SSL on the device as shown below (under Network Settings in Command Center).

- When using Enhanced WSD over SSL, “Secure Only” should be selected as Enhanced WSD Security. You can see the setting on the device shown below (under Security Settings on Command Center).

- If you want to use Enhanced WSD communication for communication with the device, you need to use the same Username and Password with it on the device.

- You can view the Authentication type and related Username and Password under Management Settings on the Command Center.

- Also, if Enhanced WSD communication with the device is NOT available, you can check if there is a “Warning” WSD status on the NetGateway device list page.

- If there is an “OK” WSD status, you can enter the correct information on Communication settings for the target device, and then click the “Refresh” button on NetGateway UI.
- This “Refresh” feature checks NetGateway to see if Enhanced WSD communication is available, based on the configured Communication settings.

Documents / Resources
![]() | Fleet Services |
References
- User Manualmanual.tools